[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-003":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-003","fire-112-1-alarm-evacuation-003",112,1,3,"依據標示設備檢修基準，下列何者非性能檢查之檢查項目？",{"A":16,"B":17,"C":18,"D":19},"檢查開關","端子電壓","緊急電源","信號裝置","B",null,[],false,"本題考點：標示設備性能檢查（避難指標除外）所列之檢查項目清單。\n【正解理由】依《消防安全設備及必要檢修項目檢修基準》第十七章標示設備二、性能檢查（避難指標除外），檢查方法所列項目為光源、檢查開關、保險絲類、結線連接、緊急電源、信號裝置六項，其中並無端子電壓，故選 B。\n【逐項排除】\n(A) 屬性能檢查項目。檢查開關以目視確認有無變形及端子有無鬆動，並由檢查開關進行常用電源之切斷及復舊操作，確認切換功能是否正常。\n(B) 非性能檢查項目。端子電壓是火警自動警報設備、緊急電源插座等章的項目，標示設備本節所列六項中並未出現，為本題應選者。\n(C) 屬性能檢查項目。緊急電源係確認於緊急電源切換狀態時有無正常瞬時亮燈，判定為應無不亮燈或閃爍之情形。\n(D) 屬性能檢查項目。信號裝置指閃滅、音聲引導、減光、消燈等功能動作之移報裝置，以手動或火警自動警報設備之探測器動作等方法確認功能是否正常。\n【記憶點】標示設備性能檢查六項：光源、檢查開關、保險絲、結線、緊急電源、信號裝置，就是沒有端子電壓。","標示設備的檢修分外觀檢查與性能檢查兩段，本題問的是性能檢查，答題前要先把兩段的項目分清楚。第十七章一、外觀檢查（一）避難方向指示燈及出口標示燈列四項：緊急電源（限內置型）之外形與標示、外箱及標示面、光源、信號裝置。其中外箱及標示面除確認有無變形、變色、脫落或污損外，還要確認辨識上之障礙，包括是否依規定之高度及位置設置、有無因內部裝修致設置位置不適當或數量不足、燈具周圍有無隔間牆或寄物櫃造成視覺辨識障礙、有無雜亂物品或廣告板遮蔽。\n性能檢查的六項則各有判定：光源應無污損或顯著劣化；檢查開關應無變形、損傷或端子鬆動，切斷常用電源時應能自動切換至緊急電源即時亮燈，復舊時亦能自動切換回常用電源；保險絲類應無損傷、熔斷且為所定種類及容量；結線連接應無斷線、端子鬆動、脫落、損傷；緊急電源應無不亮燈或閃爍；信號裝置則要求燈光閃滅正常、音聲鳴動正常、點燈正常（限消燈型或減光型）。注意事項中還提醒，以緊急電源亮燈時光線會比常用電源稍暗，屬正常範圍，且檢查後應復歸為一般常用電源。\n與標示設備最常一起考的是第十九章緊急照明設備二、性能檢查，那一章的性能檢查項目是照度、檢查開關、保險絲類、結線接續、緊急電源，判定為地下建築物之地下通道應達十勒克斯以上、其他場所應達二勒克斯以上，緊急電源容量應能持續三十分鐘以上，這與第一百七十八條的設置規定一致；其檢查數量是級距表，總樓地板面積 1000m2 以下 5 個以上、3000m2 以下 10 個以上、6000m2 以下 15 個以上、10000m2 以下 20 個以上、超過 10000m2 者 20 個加上每增加 5000m2 增加 5 個。",true,[28,32,36,39,43,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-002","依據緊急電源插座檢修基準，有關性能檢查之判定方法，下列敘述何者錯誤？",2,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-004","依據一一九火災通報裝置檢修基準之性能檢查，下列何者非預備電源檢查方法之項目？",4,{"webId":37,"stem":38,"number":12,"year":11,"session":12},"fire-112-1-alarm-evacuation-001","依據配線檢修基準性能檢查之檢查方法，有關高壓回路電源回路間及電源回路與大地間之絕緣電阻值測定，下列敘述何者錯誤？",{"webId":40,"stem":41,"number":42,"year":11,"session":12},"fire-112-1-alarm-evacuation-005","有關瓦斯漏氣檢知器一回路設置數量，依據瓦斯漏氣火警自動警報設備檢修基準之性能檢查，有關撰取檢查數量，下列敘述何者正確？",5,{"webId":44,"stem":45,"number":46,"year":47,"session":12},"fire-111-1-alarm-evacuation-040","光電式分離型探測器進行外觀試驗，以目視確認探測器光軸應平行牆壁距離 X 公分以上，且探測器之光軸高度應在天花板等高度 Y%以上之位置。而使用減光罩進行動作試驗，非蓄積型探測器之動作時間應在 Z 秒內。則 X、Y、Z 值，下列何者正確？",40,111,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-006","有關室內排煙綜合試驗之排煙風量測試，依據排煙設備測試報告書判定要領，下列敘述何者錯誤？",6,[53,57,60,64,68],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-003",113,"下列場所不得免設排煙設備？",{"webId":58,"year":47,"stem":59,"number":13},"fire-111-1-alarm-evacuation-003","下列場所何者依規定應設置火警自動警報設備？",{"webId":61,"year":62,"stem":63,"number":13},"fire-110-1-alarm-evacuation-003",110,"建築物有某一樓層樓地板面積 900 平方公尺且設置之避難方向指示燈均為 C 級，該樓層最有可能為下列何種用途？",{"webId":65,"year":66,"stem":67,"number":13},"fire-109-1-alarm-evacuation-003",109,"瓦斯對於空氣之比重大於 1 時，其瓦斯漏氣檢知器應設於距瓦斯燃燒器具水平距離多少公尺以內？",{"webId":69,"year":70,"stem":71,"number":13},"fire-108-1-alarm-evacuation-003",108,"用途為補習班，居室樓地板面積 300 平方公尺，採用有效通風方式檢討，其排煙口設於天花板下方 80 公分內，試問有效通風面積最少須要多少平方公尺以上方可符合規定？",1785129962937]