[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-002":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-002","fire-112-1-alarm-evacuation-002",112,1,2,"依據緊急電源插座檢修基準，有關性能檢查之判定方法，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"插座之插頭應可輕易拔出及插入","開關器之開、關應能正常","端子電壓單相以三用電表確認一般常用電源及緊急電源之單相交流端子電壓應於規定之範圍內","回轉相位連接額定電壓 220 V 之三相交流緊急電源插座，如與電動機連接時，以相位計確認應為逆回轉（左向回轉）之方向","D",null,[],false,"本題考點：緊急電源插座性能檢查之判定方法，關鍵在三相交流插座回轉相位之方向。\n【正解理由】依《消防安全設備及必要檢修項目檢修基準》第二十三章緊急電源插座二、性能檢查「回轉相位」之判定方法，應為正回轉（右向回轉）之方向；本選項寫成逆回轉（左向回轉），方向與判定方法相反，故選 D。\n【逐項排除】\n(A) 正確。「插座」之檢查方法為確認插頭是否可輕易拔出及插入，判定方法為插頭應可輕易拔出及插入。\n(B) 正確。「開關器」之檢查方法為以開關操作確認開、關性能是否正常，判定方法為開、關應能正常。\n(C) 正確。「端子電壓」單相之檢查方法為以三用電表確認一般常用電源及緊急電源之單相交流端子電壓是否為規定值，判定方法為應於規定之範圍內。\n(D) 錯誤。回轉相位之檢查方法為連接額定電壓 220V 之三相交流緊急電源插座，如與電動機連接時以相位計確認其是否依規定方向回轉，判定方法明定為正回轉（右向回轉）。\n【記憶點】緊急電源插座性能檢查四項：插座、開關器、端子電壓、回轉相位，相位一律右轉為正。","緊急電源插座是消防搶救上之必要設備，第十一條所列六種設備中排第四款，其餘為連結送水管、消防專用蓄水池、排煙設備、無線電通信輔助設備與防災監控系統綜合操作裝置。它的功能是在火災時供搶救器材取電，因此檢修的四個項目全部圍繞著「插得上、開得起來、電壓對、轉向對」。\n性能檢查的四項可與外觀檢查對照著記。第二十三章一、外觀檢查列保護箱、插座、開關器、表示燈四項：保護箱面應有「緊急電源插座」之字樣且字體無污損，箱門可確實正常開關；插座部分明定單相交流 110V 用者應為額定 150V、15A 之接地型插座，三相交流 220V 用者則適用額定 250V、30A 之接地型插座，並確認應無變形、損傷、顯著腐蝕或異物阻塞；開關器確認開關位置是否正常；表示燈確認是否正常亮燈。外觀看的是「有沒有壞」，性能檢查看的是「動起來對不對」。\n端子電壓一項在檢修基準裡分單相與三相兩種檢查方法，都是以三用電表確認一般常用電源及緊急電源之交流端子電壓是否為規定值，判定則一律是應於規定之範圍內，並未給定一個固定數字，這點與火警自動警報設備第十三章預備電源及緊急電源之端子電壓判定為「電壓表指針指在紅色線以上」不同，也與惰性氣體滅火設備第十一章緊急電源之端子電壓判定為「操作電池試驗用開關約三秒，電壓計安定時之容量應在規定電壓值範圍內」不同。同名項目在不同章的判定方式各異，作答時要先看題幹問的是哪一章。\n檢查器具也可構成記憶點：插座與開關器靠實際操作確認，端子電壓靠三用電表，回轉相位靠相位計，器具與項目一一對應。四項之中只有回轉相位給了明確方向值，其餘三項的判定都是定性描述，題目若在這三項上塞進具體數字，多半就是加料。",true,[28,31,35,40,44,48],{"webId":29,"stem":30,"number":12,"year":11,"session":12},"fire-112-1-alarm-evacuation-001","依據配線檢修基準性能檢查之檢查方法，有關高壓回路電源回路間及電源回路與大地間之絕緣電阻值測定，下列敘述何者錯誤？",{"webId":32,"stem":33,"number":34,"year":11,"session":12},"fire-112-1-alarm-evacuation-003","依據標示設備檢修基準，下列何者非性能檢查之檢查項目？",3,{"webId":36,"stem":37,"number":38,"year":39,"session":12},"fire-111-1-alarm-evacuation-040","光電式分離型探測器進行外觀試驗，以目視確認探測器光軸應平行牆壁距離 X 公分以上，且探測器之光軸高度應在天花板等高度 Y%以上之位置。而使用減光罩進行動作試驗，非蓄積型探測器之動作時間應在 Z 秒內。則 X、Y、Z 值，下列何者正確？",40,111,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-004","依據一一九火災通報裝置檢修基準之性能檢查，下列何者非預備電源檢查方法之項目？",4,{"webId":45,"stem":46,"number":47,"year":39,"session":12},"fire-111-1-alarm-evacuation-039","民國 84 年取得使用執照之大樓，測試其火警地區音響裝置之音壓何者正確？",39,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-005","有關瓦斯漏氣檢知器一回路設置數量，依據瓦斯漏氣火警自動警報設備檢修基準之性能檢查，有關撰取檢查數量，下列敘述何者正確？",5,[53,57,60,64,68],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-002",113,"對於緊急電源插座距離樓地板的裝設高度範圍，下列何者正確？",{"webId":58,"year":39,"stem":59,"number":13},"fire-111-1-alarm-evacuation-002","平時有人之公共危險物品製造、儲存或處理場所，若未達應設置火警自動警報設備之規定時，其儲存、處理公共危險物品數量達幾倍管制量以上，應設置手動報警設備或具同等功能之緊急通報裝置？",{"webId":61,"year":62,"stem":63,"number":13},"fire-110-1-alarm-evacuation-002",110,"某樓高 12 層觀光旅館於最高樓層開設之餐廳，依各類場所消防安全設備設置標準之規定，其位於同樓層的廚房無須設置下列何種裝置？",{"webId":65,"year":66,"stem":67,"number":13},"fire-109-1-alarm-evacuation-002",109,"使用「加瓦斯試驗器」進行瓦斯漏氣檢知器性能檢查時，若檢測對象的瓦斯對空氣之比重大於 1 者，應使用何種氣體來檢測？",{"webId":69,"year":70,"stem":71,"number":13},"fire-108-1-alarm-evacuation-002",108,"特別安全梯的安全梯與緊急昇降機兼用時，其排煙機、進風機之排煙量、進風量須在每秒多少立方公尺以上？",1785129962922]