[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-111-1-fire-science-030":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"火災學概要","fire-science","火災學 · Fire Science","火災學",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-111-1-火災學概要-030","fire-111-1-fire-science-030",111,1,30,"下列對高樓逃生通道設計原則的描述，何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"逃生通道應簡單明瞭，路短比路直重要","逃生以固定設施為主，可搬式器具、裝置為輔","逃生對策應重視直覺，故以圖形或箭頭等簡單符號指示避難方向或出口較佳","建築物出口數目，視收容人數多寡而定","A",null,[],false,"本題考點：避難逃生路徑的設計原則與人類避難行為特性。\n【正解理由】避難路徑設計的第一要求是單純明瞭，讓人在濃煙與高度緊張下仍能憑直覺前進；一條雖短卻多次轉折、需要反覆判斷方向的路徑，遠比稍長但筆直、看得到終點的路徑危險。因此正確的原則是路直重於路短，(A) 寫成「路短比路直重要」把優先順序顛倒，題目要選錯誤者，故選 A。\n【逐項排除】\n(A) 敘述錯誤，為本題應選者：避難路徑以單純、直通為優先，長度短並不能彌補轉折多、易迷失方向的缺點。\n(B) 樓梯、避難通道等固定設施可承受大量人員連續使用，避難器具屬輔助手段，僅在固定設施無法使用時供少數人使用，主從關係敘述正確。\n(C) 濃煙下閱讀文字困難，且人在緊張時判讀能力下降，以箭頭、圖形等簡單符號指示方向確實較文字有效，敘述正確。\n(D) 出口數量與寬度依收容人數推算，人數愈多所需出口與寬度愈大，才能在容許時間內完成避難，敘述正確。\n【記憶點】避難路徑直比短重要，固定設施優先於器具。","避難計畫的設計原則可以整理成幾條互相支撐的規則：兩方向避難、路徑單純明瞭、以固定設施為主器具為輔、逐級提升安全度的區劃，以及直覺化的引導。\n路徑單純明瞭之所以優先於路徑最短，理由來自人在火場的行為特性。緊張與濃煙會使視野、判讀能力與空間認知同時下降，此時每一個轉折都是一次必須做出的判斷，而判斷錯誤的代價是折返或走入死路。火災學常引用的避難行為傾向包括：歸巢性（往進來的路走回去）、日常動線本能（走平常最熟的路）、向光性（往亮處走）、追隨本能（跟著前面的人走）與退避本能（背離火煙方向）。一條筆直、看得到出口且亮度足夠的路徑，正好同時滿足向光性與退避本能，把人的本能變成助力而不是阻力。\n以固定設施為主的道理相近：樓梯與避難通道能承受大量人員連續通過，且不需要學習與體力；避難器具的操作需要時間與訓練，只在固定設施無法使用時發揮作用，兩者不可主客易位。\n安全區劃的逐級概念則是把避難分段：由居室退到走廊，再退到樓梯間，最後抵達地面或戶外安全處所，每一段都比前一段更能阻擋煙與火，避難時間因此被切成數個可承受的區段，這也是高層建築設避難層與特別安全梯的理由。\n相關考點連結：出口數量與寬度依收容人數推算的計算題、標示設備中出口標示燈與避難方向指示燈的功能區辨，以及必要避難時間與容許避難時間的比較模式。\n易混淆對照：路徑「單純」與路徑「短」在一般情形下並不衝突，只有兩者無法兼顧時才需要排序，本題考的正是這個排序；同樣地，兩方向避難要求的是兩條互相獨立、不會同時被同一處火煙封閉的路徑，把同一條走廊的左右兩端算成兩個方向是常見的判讀陷阱。另須留意，這些原則的共同目的是讓必要避難時間小於容許避難時間，任何一項被犧牲，整體安全裕度都會跟著下降。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-111-1-fire-science-029","建築物內部裝潢材料對閃燃時間（F.O.T.）的影響，下列敘述何者錯誤？",29,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-111-1-fire-science-031","常見消防機關宣導，使用延長線勿將其綑綁，以免引發火災，究其原因為何？",31,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-111-1-fire-science-028","通風控制燃燒下，居室內有可燃物 1200 kg，該居室有一開口面積 6 m2，高度 2 m，則火災持續時間約幾分鐘？",28,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-111-1-fire-science-032","下列何者非油槽火災發生沸溢或濺溢的主要因素？",32,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-111-1-fire-science-027","下列關於乙炔的敘述，何者錯誤？",27,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-111-1-fire-science-033","執行危害性化學品災害搶救指導原則（HAZMAT），下列有關區域管制（Zoning）敘述何者錯誤？",33,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-fire-science-030",113,"有關煙控分析中「等效流動面積」的定義，下列敘述何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-fire-science-030",112,"滅火藥劑的供給率關乎火災初期的滅火成敗、滅火時間與藥劑使用量，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-fire-science-030",110,"某建築物火場產生大量煙霧，正向煙囪效應在中性帶以上 10 公尺處的壓力差為 12 Pa，若建築物內、外的溫度差不變，請問中性帶以上 20 公尺處的壓力差為何？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-fire-science-030",109,"海龍替代滅火藥劑中，下列何者在大氣之滯留時間最久？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-fire-science-030",108,"下列何種措施，可以防止由大樓窗口噴出的火焰向上層延燒？",1785129966861]