[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-111-1-fire-law-036":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-111-1-消防法規概要-036","fire-111-1-fire-law-036",111,1,36,"受託辦理檢修之檢修機構應依相關規定檢修完成消防安全設備後，依照消防安全設備檢修及申報辦法規定，應附加檢修完成標示檢修機構專業樣式以何種顏色為底？",{"A":16,"B":17,"C":18,"D":19},"藍色","黃色","綠色","紅色","D",null,[],false,"本題考點：檢修完成標示之樣式區分，檢修機構專業樣式所採用之底色。\n【正解理由】依《消防法》第 9 條第 1 項第一款，高層建築物、地下建築物或中央主管機關公告之場所，其消防安全設備定期檢修應委託中央主管機關許可之消防安全設備檢修專業機構辦理；同條第 2 項將檢修完成標示之規格、樣式、附加方式與位置授權中央主管機關訂定辦法，即《消防安全設備檢修及申報辦法》。檢修完成標示依受託辦理檢修之主體分成不同樣式，其中檢修機構專業樣式以紅色為底，故選 D。（候選條文未附該辦法原文，故僅引至授權條文層級。）\n【逐項排除】\n(A) 藍色：非檢修機構專業樣式之底色；藍色係《檢修基準》第一章滅火器所定檢修環一百一十四年度之顏色，屬另一套識別制度。\n(B) 黃色：非檢修機構專業樣式之底色；黃色為檢修環一百一十二年度之顏色。\n(C) 綠色：非檢修機構專業樣式之底色；綠色為檢修環一百一十三年度之顏色，滅火器壓力指示計之正常指示範圍亦以綠色表示。\n(D) 紅色：與該辦法所定檢修機構專業樣式之底色相符，為本題應選者。\n【記憶點】檢修完成標示依檢修主體分色，檢修專業機構者為紅底。","檢修完成標示是《消防法》第 9 條 111 年 5 月 11 日修正後強化的管理工具。修正後的第 1 項把檢修結果的申報對象明定為場所所在地主管機關並得派員複查，第 2 項則一次列舉授權辦法應規範之事項，包括定期檢修之項目、方式、基準、頻率，檢修必要設備與器具之定期檢驗或校準，檢修完成標示之規格、樣式、附加方式與位置，受理檢修結果之申報期限，報請審核時之查核與處理方式等。標示之所以要依檢修主體分色，是因為第 1 項本身就依場所風險把檢修主體分成三類：檢修專業機構、消防設備師（士），以及僅設非系統式設備場所之管理權人自行辦理，分色可讓消防機關與使用人一眼辨識該場所的檢修是由何種主體完成，便於後續查核。\n檢修專業機構的管理密度最高。《消防安全設備檢修專業機構管理辦法》第 2 條定義檢修機構為經中央主管機關許可辦理高層建築物或地下建築物消防安全設備定期檢修業務之專業機構；第 3 條定資格：須為法人組織、實收資本額或資本總額或登記財產總額在新臺幣五百萬元以上、營業項目或章程載有消防安全設備檢修項目、置有消防設備師及消防設備士合計十人以上且均為專任其中消防設備師至少二人、並具備執行檢修業務之必要設備與器具；第 5 條要求取得許可前須檢具已投保專業責任保險證明文件，最低保險金額為每一次事故新臺幣一千二百萬元、保險期間內累計新臺幣二千四百萬元，且應於證書有效期限內持續有效並續保。\n業務執行面，第 8 條要求不得違反法令、不得以詐欺脅迫或其他不正當方法招攬業務、不得無故洩漏業務秘密，並須由消防設備師或消防設備士親自執行職務、據實填寫檢修報告書，高層建築物或地下建築物之檢修更須由二名以上師（士）共同執行。書表方面，第 13 條規定應於年度開始前二個月至一個月內報備次年度檢修業務計畫書、人員訓練計畫書及師（士）名冊；第 14 條規定年度終結後五個月內報備上年度執行報告書、薪資明細、訓練成果及保險證明。違反執行業務規範或書表陳報規定者，依《消防法》第 38 條第 4 項處三萬元以上十五萬元以下罰鍰並限期改善，屆期未改善得按次處罰，並得予三十日以下停業處分或廢止許可。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-111-1-fire-law-035","某合法 KTV 視聽歌唱場所經當地消防機關會勘通過依法取得室內裝修許可，依照消防安全設備檢修及申報辦法規定，自該室內裝修許可核發之日期起算，距申報期限在多少個月以內，免辦理當次檢修及申報備查？",35,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-111-1-fire-law-037","依據乾粉滅火設備各種標示規格規定，其標示規格為長 480 mm 以上，寬 270 mm 以上，黃底黑字，每字大小為 25 mm×25 mm 以上，係屬下列何者？",37,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-111-1-fire-law-034","依消防安全設備及必要檢修項目檢修基準規定，對二氧化碳滅火器進行重量檢查時，如失重超過多少比例以上或壓力表示值在綠色範圍外時，應予以更新，下列何者正確？",34,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-111-1-fire-law-038","有關加壓送水裝置之電動機，其種類、構造及機能等之敘述，何者正確？",38,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-111-1-fire-law-033","依消防法施行細則規定，供公眾使用建築物應遴選防火管理人並制定消防防護計畫，其相關規定下列何者錯誤？",33,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-111-1-fire-law-039","避難器具裝置在固定部上之固定器具材料如為鋼材，其鋼索之容許拉伸應力為剪斷荷重的多少比例？",39,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-036",114,"消防設備人員執行消防安全設備之測試業務，製作測試報告書是由消防安全設備測試人員依滅火設備、警報設備、避難逃生設備、消防搶救上之必要設備及其他經中央主管機關認定之消防安全設備等依序製表，並確認各項消防安全設備之試驗符合規定。下列何者非屬應實施之試驗？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-036",113,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，有關第一類公共危險物品的儲存及處理，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-036",112,"依建築技術規則之定義，自室內經由陽台或排煙室始得進入之安全梯稱為下列何者？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-law-036",110,"依建築技術規則建築設計施工編規定，夾層係指夾於樓地板與天花板間之樓層；同一樓層內夾層面積之和，超過多少平方公尺，視為另一樓層？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-036",109,"依避難器具支固器具及固定部之結構、強度計算及施工方法之規定，裝置避難器具固定部材料，使用直徑 1 公分錨定螺栓，設定試驗荷重 500 公斤力（kgf）時，則鎖緊扭力應為多少公斤力\u002F公分（kgf\u002Fcm）？",1785129969570]