[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-111-1-fire-law-014":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-111-1-消防法規概要-014","fire-111-1-fire-law-014",111,1,14,"下列那一場所不是應設置無線電通信輔助設備之場所？",{"A":16,"B":17,"C":18,"D":19},"地下層在四層以上，且地下層樓地板面積合計在 3 千平方公尺以上建築物之地下層","總樓地板面積在 1 千平方公尺以上之地下建築物","樓高在 100 公尺以上建築物之地下層","總樓地板面積在 1 萬平方公尺以上之建築物","D",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 30 條所列應設置無線電通信輔助設備之場所。\n【正解理由】第 30 條明定下列場所應設置無線電通信輔助設備：一、樓高在一百公尺以上建築物之地下層；二、總樓地板面積在一千平方公尺以上之地下建築物；三、地下層在四層以上，且地下層樓地板面積合計在三千平方公尺以上建築物之地下層。三款均以地下層或地下建築物為對象，並無單以建築物總樓地板面積達一萬平方公尺即應設置之規定，D 不在該條所列之內，故選 D。\n【逐項排除】\n(A) 與第 30 條第三款相符，地下層在四層以上且地下層樓地板面積合計在 3 千平方公尺以上建築物之地下層應設置，屬應設場所。\n(B) 與第 30 條第二款相符，總樓地板面積在 1 千平方公尺以上之地下建築物應設置，屬應設場所。\n(C) 與第 30 條第一款相符，樓高在 100 公尺以上建築物之地下層應設置，屬應設場所。\n(D) 總樓地板面積在 1 萬平方公尺以上之建築物並未列於第 30 條各款，非應設場所，為本題應選者。\n【記憶點】無線電通信輔助設備三款全鎖定地下：百米樓的地下層、千平方公尺地下建築物、地下四層且三千平方公尺。","無線電通信輔助設備是《設置標準》第 11 條所定消防搶救上之必要設備六種之一，與連結送水管、消防專用蓄水池、排煙設備、緊急電源插座、防災監控系統綜合操作裝置並列。三款應設場所全部指向地下，是因為無線電波在地下層與地下建築物會被鋼筋混凝土大量衰減，消防人員入室後與指揮位置失聯的風險最高，故以洩波同軸電纜把訊號延伸進去。技術規格見第 192 條：洩波同軸電纜應適合傳送或輻射一百五十百萬赫（MHz）或中央主管機關指定之周波數，標稱阻抗為五十歐姆，並經耐燃處理；分配器、混合器、分波器及其他類似器具應使用介入衰耗少，且接頭部分有適當防水措施者；設增輻器時，其緊急電源應使用蓄電池設備，能量能使其有效動作三十分鐘以上。接頭是常考細節：應設於地面消防人員便於取用處及值日室等平時有人之處所，設於地面之接頭數量在任一出入口與其他出入口之步行距離大於三百公尺時應設二個以上，裝設高度在距樓地板面或基地地面零點八公尺至一點五公尺間，並裝設於保護箱內，箱內設長度二公尺以上之射頻電纜，保護箱應構造堅固、有防水及防塵措施，箱面漆紅色並標明消防隊專用無線電接頭字樣；共構之建築物內有二處以上場所設置時，應有能使該設備訊號連通之措施。同章其他設備的門檻可並列對照：第 26 條連結送水管為五層或六層建築物總樓地板面積在六千平方公尺以上者及七層以上建築物、總樓地板面積在一千平方公尺以上之地下建築物；第 29 條緊急電源插座為十一層以上建築物之各樓層、總樓地板面積在一千平方公尺以上之地下建築物、依建築技術規則應設置之緊急昇降機間。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-111-1-fire-law-013","某建築物設置收納金屬製避難梯為避難器具，其升降口之施工方法何者錯誤？",13,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-111-1-fire-law-015","某一百貨商場為地上八層、地下三層，總樓地板面積 3 千平方公尺。其火警自動警報設備之鳴動方式何者錯誤？",15,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-111-1-fire-law-012","消防幫浦加壓送水裝置中，有關呼水裝置規定之敘述，下列何者錯誤？",12,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-111-1-fire-law-016","防災監控系統綜合操作裝置之緊急電源供電容量應供其有效動作多少小時以上？",16,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-111-1-fire-law-011","有關二氧化碳滅火設備使用之各種標示規格，下列敘述何者錯誤？",11,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-111-1-fire-law-017","下列那一處公共危險物品之場所屬於一般滅火困難場所？",17,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-014",114,"依消防安全設備檢修及申報辦法規定，檢修人員或檢修機構完成消防安全設備檢修後，附加檢修完成標示，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-014",113,"依消防法規定，高層建築物之防災中心或地下建築物之中央管理室，應置服勤人員，並經主管機關或經中央主管機關登錄之專業機構施予一定時數之訓練，領有合格證書，始得充任；任職期間，並應定期接受複訓。試問初訓合格者，應多久時間複訓 1 次？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-014",112,"某一室外儲槽容量為 30 公秉，其儲存閃火點在攝氏 21 度以上未達 70 度之六類公共危險物品，依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，該儲槽之周圍保留空地至少應為多少公尺以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-law-014",110,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，有關場所之定義，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-014",109,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，關於可燃性高壓氣體儲存場所構造、設備及安全管理之規定，通路面積至少應占儲存場所面積之百分之多少以上？",1785129969422]