[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-111-1-alarm-evacuation-031":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-111-1-警報與避難系統消防安全設備概要-031","fire-111-1-alarm-evacuation-031",111,1,31,"設置 119 火災通報裝置的主要功能為何？",{"A":16,"B":17,"C":18,"D":19},"使消防勤務中心能清楚詢問火場訊息","火警受信總機故障時之備援設備機制","輔助場所人力不足時之緊急應變通報","火警受信總機擴充連動周邊防災設備","C",null,[],false,"本題考點：一一九火災通報裝置的功能定位，由《各類場所消防安全設備設置標準》第 22-1 條與第 145-1 條判讀。\n【正解理由】第 22-1 條所定應設場所為醫院、療養院、榮譽國民之家、長期照顧服務機構、老人福利機構、護理機構及照顧植物人、失智症、重癱、長期臥床或身心功能退化者之身心障礙福利機構等，收容人員自行避難與報案能力有限；第 145-1 條要求該裝置應具手動及自動啟動功能，設於值日室等經常有人之處所，附近並應設置送、收話器且與其他內線電話明確區分。《消防安全設備及必要檢修項目檢修基準》一一九火災通報裝置之性能檢查，亦以優先通報機能（電話機使用中時應能強制切斷，優先送出蓄積語音）、通報自始播放與再撥號機能為判定項目，可見其設計是以蓄積語音自動報案、補足現場人力，故選 C。\n【逐項排除】\n(A) 裝置雖有回撥後之通話機能，但判定項目以蓄積語音完整、明瞭、清晰地送出為主，非供勤務中心詢問火場情形。\n(B) 第 9 條把一一九火災通報裝置與火警自動警報設備並列為警報設備之各一種，其自動啟動係與火警自動警報設備連動，非總機故障時之替代品。\n(C) 以手動或自動啟動送出蓄積語音報案，輔助人力不足場所之緊急應變通報，為本題應選者。\n(D) 連動監控周邊防災設備屬第 192-1 條防災監控系統綜合操作裝置之功能。\n【記憶點】一一九火災通報裝置＝一鍵送出蓄積語音報案，補人力不足的通報缺口。","一一九火災通報裝置在《各類場所消防安全設備設置標準》第 9 條被列為警報設備第五款，與火警自動警報設備、手動報警設備、緊急廣播設備、瓦斯漏氣火警自動警報設備並列，這個位置本身就說明它是獨立的一種警報設備，不是其他設備的備援。第 22-1 條所列應設場所高度集中在醫療與長照類：醫院、療養院、榮譽國民之家、長期照顧服務機構（限機構住宿式、社區式之建築物使用類組非屬Ｈ－２之日間照顧、團體家屋及小規模多機能）、老人福利機構（限長期照護型、養護型、失智照顧型之長期照顧機構、安養機構）、護理機構（限一般護理之家、精神護理之家）、身心障礙福利機構（限照顧植物人、失智症、重癱、長期臥床或身心功能退化者），以及其他經中央主管機關公告之供公眾使用之場所。這些場所值班人力有限、收容人員多無法自行報案，法規因此要求一套能自動或一鍵完成報案的裝置。\n第 145-1 條六款設置規定都指向同一個設計意圖：應具手動及自動啟動功能；應設於值日室等經常有人之處所，但設有防災中心時應設於該中心；設置遠端啟動裝置時，應設有可與設置場所通話之設備；手動啟動裝置之操作開關距離樓地板面之高度在零點八公尺以上一點五公尺以下；裝置附近應設置送、收話器，並與其他內線電話明確區分；應避免斜裝置，並採取有效防震措施。\n檢修與驗收面更能看出功能定位。《消防安全設備及必要檢修項目檢修基準》一一九火災通報裝置之性能檢查項目包括啟動機能（手動啟動、與火警自動警報設備連動啟動）、優先通報機能、通報自始播放機能、手動啟動裝置優先機能、蓄積語音訊息、再撥號機能與通話機能，判定方式為動作時以中文字幕或國語音效顯示。至於整合監控其他消防安全設備，那是第 192-1 條防災監控系統綜合操作裝置的任務：該裝置應設於防災中心、中央管理室或值日室等經常有人之處所，監控或操作火警受信總機、瓦斯漏氣受信總機、緊急廣播設備之擴大機及操作裝置、連結送水管之加壓送水裝置及其送水口處之通話連絡、緊急發電機、常開式防火門之偵煙型探測器、室內消防栓等滅火設備加壓送水裝置、乾粉等滅火設備及排煙設備，其緊急電源供電容量並應供其有效動作二小時以上。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-111-1-alarm-evacuation-030","依各類場所消防安全設備設置標準規定，有關緊急廣播設備敘述下列何者錯誤？",30,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-111-1-alarm-evacuation-032","某場所進行緊急廣播設備綜合檢查，使用噪音計（A 特性）量測揚聲器之音壓位準，在距 L 級揚聲器 1 公尺處，音壓位準值應在 X dB 以上；又挑高空間採性能設計之指向型揚聲器，於廣播區域內任一位置距樓地板面 Y 公尺處，音壓位準值應在 Z dB 以上。則 X、Y、Z 值，下列何者正確？",32,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-111-1-alarm-evacuation-029","緩降機為顧及使用之安全，裝置時應考慮之位置下列何者為佳？",29,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-111-1-alarm-evacuation-033","依消防安全設備測試報告書測試方法及判定要領，有關瓦斯漏氣火警自動警報設備檢知器之動作試驗，以加瓦斯試驗器將試驗瓦斯加進檢知器，測定至瓦斯漏氣表示為止之時間，下列何者正確？",33,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-111-1-alarm-evacuation-028","非局限型探測器為有效偵知火災，下列何者為設置標準規定裝設於小空間內至少應有的長度或元件數量？",28,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-111-1-alarm-evacuation-034","二氧化碳滅火系統全區放射的空間，以往造成人員死傷之動作噴發，與防護空間下列因素何者無關？",34,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-031",113,"避難器具於竣工查驗時，針對固定架或支固器具使用螺栓固定實施性能試驗，為確認螺栓對拉出之耐力，進行拉拔強度試驗。今使用直徑 10 毫米錨定螺栓，設計拉拔荷重（試驗荷重）為 960 公斤力（kgf），使用扭力扳手作為測定拉拔荷重之器具時，則鎖緊扭力應為多少公斤力-公分（kgf．cm）？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-031",112,"依消防安全設備及必要檢修項目檢修基準，執行緊急廣播設備性能檢查時，對啟動裝置狀態於檢查後判定方法，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-031",110,"一一九火災通報裝置，下列規定何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-031",109,"有關緊急照明設備性能檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-031",108,"依各類場所消防安全設備設置標準對於出口標示燈設置之相關規定，下列何者正確？",1785129963674]