[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-111-1-alarm-evacuation-021":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-111-1-警報與避難系統消防安全設備概要-021","fire-111-1-alarm-evacuation-021",111,1,21,"依各類場所消防安全設備設置標準規定，下列有關出口標示燈及避難方向指示燈之敘述，何者正確？",{"A":16,"B":17,"C":18,"D":19},"緊急電源應使用蓄電池設備，其容量應能使其有效動作 30 分鐘","高層建築物，其總樓地板面積在 30000 平方公尺以上，設於主要避難路徑，其容量應在 60 分鐘以上，並得採蓄電池設備及緊急發電機併設方式","出口標示燈及避難方向指示燈之有效範圍，指至該燈之步行距離，在有不易看清或識別該燈情形者，該有效範圍為 15 公尺","避難方向指示燈設於樓梯或坡道者，在樓梯級面或坡道表面之照度，應在 2 勒克司（lx）以上","B",null,[],false,"本題考點：出口標示燈及避難方向指示燈的三組法定數值，分別在《各類場所消防安全設備設置標準》第 155 條（緊急電源容量）、第 146-2 條（有效範圍）與第 146-5 條（樓梯坡道照度）。\n【正解理由】第 155 條規定緊急電源應使用蓄電池設備、容量應能使其有效動作二十分鐘以上；但設於該條第一款至第三款場所之主要避難路徑者，容量應在六十分鐘以上，並得採蓄電池設備及緊急發電機併設方式，其中第二款為「高層建築物，其總樓地板面積在三萬平方公尺以上」。(B) 與該款及但書逐字相符，故選 B。\n【逐項排除】\n(A) 第 155 條本文所定容量為有效動作二十分鐘以上，不是三十分鐘。\n(B) 即第 155 條但書第二款之情形，高層建築物總樓地板面積三萬平方公尺以上者，其主要避難路徑容量六十分鐘以上並得採併設方式，為本題應選者。\n(C) 第 146-2 條本文明定有不易看清或識別該燈情形者，該有效範圍為十公尺，不是十五公尺；十五公尺是同條表列 C 級出口標示燈之步行距離。\n(D) 第 146-5 條第三項明定避難方向指示燈設於樓梯或坡道者，在樓梯級面或坡道表面之照度應在一勒克司（lx）以上，不是二勒克司。\n【記憶點】標示設備緊急電源二十分鐘；五萬平方公尺建築物、高層建築物三萬平方公尺、地下建築物一千平方公尺之主要避難路徑為六十分鐘；不易看清時有效範圍十公尺、樓梯坡道照度一勒克司。","標示設備的常考數字分別掛在四條，可以一次記齊。第 155 條管緊急電源：本文為蓄電池設備、有效動作二十分鐘以上；但書把三種場所之主要避難路徑提高到六十分鐘以上並得採蓄電池設備及緊急發電機併設方式，三種場所為總樓地板面積在五萬平方公尺以上、高層建築物其總樓地板面積在三萬平方公尺以上、地下建築物其總樓地板面積在一千平方公尺以上。同條第二項並定義主要避難路徑為通往戶外之出入口、通往直通樓梯之出入口（設有排煙室者為該室之出入口）、通往前者出入口之走廊或通道，以及直通樓梯。\n第 146-2 條管有效範圍：原則依表列步行距離，出口標示燈 A 級未顯示避難方向符號者六十公尺、顯示者四十公尺，B 級分別為三十公尺與二十公尺，C 級十五公尺；避難方向指示燈 A 級二十公尺、B 級十五公尺、C 級十公尺。亦得依計算值 D＝kh，D 為步行距離、h 為標示面之縱向尺度，k 值為出口標示燈未顯示避難方向符號者一百五十、顯示者一百，避難方向指示燈五十。但有不易看清或識別該燈情形者，該有效範圍一律為十公尺。第 146-5 條管等級與光度：所列場所應使用 A 級或 B 級，出口標示燈標示面光度應在二十燭光（cd）以上或具閃滅功能，避難方向指示燈標示面光度應在二十五燭光（cd）以上；第三項則定設於樓梯或坡道之避難方向指示燈，在樓梯級面或坡道表面之照度應在一勒克司以上。\n免設與減光是另外兩條。第 146 條第一款按層別分寫：自居室任一點易於觀察識別其主要出入口，且步行距離在避難層為二十公尺以下、在避難層以外之樓層為十公尺以下者，得免設出口標示燈；在避難層為四十公尺以下、在避難層以外之樓層為三十公尺以下者，得免設避難方向指示燈；在三十公尺以下者，得免設避難指標，但位於地下建築物、地下層或無開口樓層者不適用。第 146-7 條則規定出口標示燈及避難方向指示燈應保持不熄滅，僅在設置場所無人期間等該條所列情形下得予減光或消燈。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-111-1-alarm-evacuation-020","依消防安全設備及必要檢修項目檢修基準，實施緊急照明設備性能檢查，檢查數量下列之敘述何者正確？",20,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-111-1-alarm-evacuation-022","避難器具安裝完成實施性能試驗，針對支固器具進行荷重試驗，緩降機至少應載重 X kg 以上；救助袋應載重 Y kg 以上，試問 X、Y 分別為何？",22,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-111-1-alarm-evacuation-019","有關緊急照明燈的緊急電源及配線之規定，下列敘述何者正確？",19,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-111-1-alarm-evacuation-023","火焰探測器偵測火災為偵測火場的何種參數？",23,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-111-1-alarm-evacuation-018","局限型偵煙探測器光電式的偵測原理若設計為散亂光式，其對火場中何種信號較不敏感？",18,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-111-1-alarm-evacuation-024","某工廠室內製程區其燃氣設備使用之燃氣以丙烷（C3H8）為主成分，現場欲設置可燃氣漏氣警報設備時，檢知器應如何安裝？",24,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-021",113,"一棟防火構造建築物，其中展覽室長 20 公尺、寬 20 公尺、高 6 公尺，天花板具有一個 50 公分的樑，將其平均分為兩個區域，試問使用補償式局限型一種探測器時，最少應設置幾顆探測器於該區域當中？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-021",112,"依各類場所消防安全設備設置標準之規定，裝設於樓梯 L 級揚聲器，距揚聲器 1 公尺處所測得之音壓規定，下列何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-021",110,"下列有關免設火警探測器之場所，何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-021",109,"有關應設置火警自動警報設備之場所，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-021",108,"依各類場所消防安全設備設置標準規定，下列危險物品場所何者不須設置火警自動警報設備？",1785129963587]