[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-110-1-water-chemical-040":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-水與化學系統消防安全設備概要-040","fire-110-1-water-chemical-040",110,1,40,"依消防安全設備及必要檢修項目檢修基準，冷卻撒水設備之供第四類公共危險物品之顯著滅火困難場所之加壓送水裝置，啟動後 X 分鐘內應能有效撒水，且加壓送水裝置距撒水區域在 Y 公尺以下，但設有保壓措施者不在此限。X、Y 分別為何？",{"A":16,"B":17,"C":18,"D":19},"X=3；Y=300","X=3；Y=500","X=5；Y=300","X=5；Y=500","D",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 216 條冷卻撒水設備，加壓送水裝置之有效撒水時間與其距撒水區域之距離。\n【正解理由】第 216 條第八款明定「加壓送水裝置啟動後五分鐘以內，能有效撒水，且加壓送水裝置距撒水區域在五百公尺以下。但設有保壓措施者，不在此限」；《消防安全設備及必要檢修項目檢修基準》第二十五章冷卻撒水設備綜合檢查之注意事項亦同旨載明五分鐘、五百公尺。X 為 5、Y 為 500，故選 D。\n【逐項排除】\n(A) X=3；Y=300：三分鐘不見於條文；三百公尺為同條第七款但書「送水區域距加壓送水裝置在三百公尺以內者，得免設遠隔啟動裝置」之門檻，講的是另一件事。\n(B) X=3；Y=500：距離與第八款相符，但三分鐘無條文依據。\n(C) X=5；Y=300：時間與第八款相符，距離誤植為第七款但書之三百公尺。\n(D) X=5；Y=500：與第 216 條第八款及檢修基準綜合檢查注意事項逐字相符，為本題應選者。\n【記憶點】五分鐘、五百公尺同寫在第 216 條第八款；三百公尺出現在同條第七款但書，講的是免設遠隔啟動裝置。","本題數值要放回第四編【公共危險物品等場所】的脈絡看。第 194 條先界定顯著滅火困難場所，室外儲槽場所以儲槽儲存液體表面積、儲槽高度等要件認定；第 201 條再以表列方式指定顯著滅火困難場所應設之第一種、第二種或第三種滅火設備；到了第 216 條，才對「以室內、室外儲槽儲存閃火點在攝氏七十度以下之第四類公共危險物品之顯著滅火困難場所」課予固定式泡沫滅火設備外加冷卻撒水設備之義務，並用九款把設備規格寫死：撒水噴孔符合 CNS 一二八五四且孔徑在四毫米以上、撒水量按槽壁總防護面積每平方公尺每分鐘二公升以上、加壓送水裝置為專用且幫浦出水量在撒水量乘以防護面積以上、水源容量在最大一座儲槽連續放水四小時之水量以上、選擇閥設於防液堤外火災不易殃及且容易接近處所（操作位置距地面零點八公尺以上一點五公尺以下）、第七款之手動與遠隔啟動裝置、第八款之五分鐘與五百公尺、第九款加壓送水裝置連接緊急電源，末項並定緊急電源除準用第 38 條外，供電容量應在其連續放水時間以上——與第五款的四小時水源互相對應。同一條裡出現的三百公尺與五百公尺分屬第七款但書（免設遠隔啟動裝置之送水區域距離）與第八款（有效撒水之距離上限），兩者的規範對象不同。第二款並定撒水管設於槽壁頂部，撒水噴頭之配置數量依其裝設之放水角度及撒水量核算，儲槽設有風樑或補強環等阻礙水路徑者，於其下方增設撒水管及撒水噴孔。檢修時，檢修基準綜合檢查係切換成緊急電源供電狀態，選配管上最遠最高之一區作放水試驗，在一齊開放閥最遠處之冷卻撒水噴頭（噴孔）附近裝測試用壓力表，以Ｑ＝Ｋ√Ｐ核算放射量，並就啟動性能、一齊開放閥動作與撒水量逐項判定。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-water-chemical-039","依消防安全設備及必要檢修項目檢修基準，冷卻撒水設備之遠隔啟動裝置，限用於儲存閃火點多少℃以下公共危險物品之室外儲槽？",39,{"webId":33,"stem":34,"number":12,"year":35,"session":12},"fire-111-1-water-chemical-001","依各類場所消防安全設備設置標準規定，下列何種場所不需設置室外消防栓設備？",111,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-water-chemical-038","依消防安全設備及必要檢修項目檢修基準，海龍滅火設備全區放射方式檢查方法，若以空氣或氮氣進行放射試驗，所需空氣量或氮氣量，應就放射區域應設滅火藥劑量之多少%核算？",38,{"webId":41,"stem":42,"number":43,"year":35,"session":12},"fire-111-1-water-chemical-002","有關室外消防栓與室內消防栓之瞄子放水壓力之敘述，下列何者正確？",2,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-water-chemical-037","依消防安全設備及必要檢修項目檢修基準，水道連結型自動撒水設備之末端查驗閥或連結之水龍頭等日常生活用水設施配置的壓力表，其放水壓力應在 X kgf\u002Fcm2 以上 Y kgf\u002Fcm2 以下。X、Y 分別為何？",37,{"webId":49,"stem":50,"number":51,"year":35,"session":12},"fire-111-1-water-chemical-003","某公共危險物品場所設置室外消防栓設備，在裝置全部消防栓數量 5 支時，其所需之水源容量至少應為多少立方公尺以上？",3,[53,57,61,64,68],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-040",113,"有關射水設備測試方法及判定要領，下列何者與消防安全設備測試報告書規定不同？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-water-chemical-040",112,"有關公共危險物品場所設置自動撒水設備規定，下列敘述何者正確？",{"webId":62,"year":35,"stem":63,"number":13},"fire-111-1-water-chemical-040","二氧化碳滅火設備採全區放射方式，採用高壓系統在進行綜合檢查時，以空氣或氮氣進行放射試驗，所需空氣量或氮氣量，應就放射區域應設滅火藥劑量之 X%核算，每公斤核算空氣量或氮氣量 Y（公升），請問前述 X、Y 為何？",{"webId":65,"year":66,"stem":67,"number":13},"fire-109-1-water-chemical-040",109,"儲槽規定設置補助泡沫消防栓時，下列敘述何者錯誤？",{"webId":69,"year":70,"stem":71,"number":13},"fire-108-1-water-chemical-040",108,"電動機之使用應符合之相關規定，下列何者錯誤？",1785129972561]