[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-water-chemical-018":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-水與化學系統消防安全設備概要-018","fire-110-1-water-chemical-018",110,1,18,"有關滅火器設置規定，下列何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"供鍋爐房等大量使用火源之處所，樓地板面積每 25 平方公尺有一滅火效能值","供電信機器室使用之場所，各層樓地板面積每 300 平方公尺有一滅火效能值","供保齡球館使用之場所，各層樓地板面積每 100 平方公尺有一滅火效能值","供學校教室使用之場所，各層樓地板面積每 200 平方公尺有一滅火效能值","B",null,[],false,"本題考點：滅火器最低滅火效能值之核算，須先依《設置標準》第 12 條認定場所類別，再套第 31 條之面積級距。\n【正解理由】依《各類場所消防安全設備設置標準》第 31 條第 1 款，供第 12 條第 1 款及第 5 款使用之場所，樓地板面積每一百平方公尺（含未滿）有一滅火效能值；供第 12 條第 2 款至第 4 款使用之場所，每二百平方公尺（含未滿）有一滅火效能值；鍋爐房、廚房等大量使用火源之處所，每二十五平方公尺（含未滿）有一滅火效能值。電信機器室為第 12 條第 3 款丙類場所第 1 目，應適用每二百平方公尺一滅火效能值，非選項所稱之每 300 平方公尺，故選 B。\n【逐項排除】\n(A) 鍋爐房等大量使用火源之處所每 25 平方公尺一滅火效能值：與第 31 條第 1 款第 3 目相符，敘述正確。\n(B) 電信機器室每 300 平方公尺一滅火效能值：電信機器室屬丙類場所，應為每二百平方公尺，敘述錯誤，為本題應選者。\n(C) 保齡球館每 100 平方公尺一滅火效能值：屬第 12 條第 1 款第 2 目甲類場所，適用每一百平方公尺，敘述正確。\n(D) 學校教室每 200 平方公尺一滅火效能值：屬第 12 條第 2 款第 3 目乙類場所，適用每二百平方公尺，敘述正確。\n【記憶點】「甲、戊 100；乙丙丁 200；火源處所 25」，第 31 條沒有 300 這一格。","這題的關鍵不在背數字，而在把場所歸到第 12 條的哪一款。第 12 條第 1 款甲類場所含電影片映演場所、歌廳舞廳、保齡球館撞球場集會堂健身休閒中心、觀光旅館飯店旅館、商場市場百貨、餐廳飲食店咖啡廳、醫院療養院長期照顧服務機構、三溫暖公共浴室等；第 2 款乙類場所含車站飛機場大廈候船室、金融機構、學校教室補習班 K 書中心、圖書館博物館、寺廟教堂納骨堂、辦公室診所、集合住宅寄宿舍、體育館活動中心、室內溜冰場游泳池、倉庫傢俱展示販售場、幼兒園等；第 3 款丙類場所僅三目——電信機器室、汽車修護廠飛機修理廠飛機庫、室內停車場及建築物依法附設之室內停車空間；第 4 款丁類場所為高度、中度、低度危險工作場所；第 5 款戊類場所為含甲類用途之複合用途建築物、其他複合用途建築物及地下建築物。因此保齡球館與飯店餐廳走一百平方公尺，電信機器室、學校教室、辦公室走二百平方公尺。\n易混淆之處在於電信機器室在別的條文另有各自的數值，不可互相牽引：第 18 條之表第七項規定電信機械室、電腦室或總機室及其他類似場所，樓地板面積在二百平方公尺以上者，應就二氧化碳或乾粉滅火設備選擇設置；第 83 條第 1 款二氧化碳全區放射方式藥劑量表，電信機械室、總機室欄為每立方公尺 1.2 ㎏、每平方公尺開口部追加 10 ㎏，其他場所欄則依容積分為 1.0、0.9、0.8、0.75 ㎏／m³，開口部追加均為 5 ㎏／㎡。\n延伸考點：第 14 條列應設滅火器之場所五款，其中第 2 款為總樓地板面積在一百五十平方公尺以上之乙、丙、丁類場所——與第 31 條是兩件事，一個決定要不要設，一個決定要設多少滅火效能值。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-water-chemical-017","密閉乾式或預動式之流水檢知裝置二次側配管，為有效排水，支管每 10 公尺傾斜 A 公分，主管每 10 公尺傾斜 B 公分。下列 A，B 何者正確？",17,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-water-chemical-019","依各類場所消防安全設備設置標準，應設置室內消防栓設備之場所，下列規定何者正確？",19,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-water-chemical-016","某觀光飯店餐廳的廚房面積 750 平方公尺，其使用火源處所設置滅火器核算之最低滅火效能值應為多少？",16,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-water-chemical-020","飛機修理廠、飛機庫樓地板面積在 200 平方公尺以上者，可就水霧、泡沫、乾粉、二氧化碳滅火設備等選擇下列何者設置之？",20,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-water-chemical-015","公共危險物品儲槽設置補助泡沫消防栓之規定，下列敘述何者錯誤？",15,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-water-chemical-021","依各類場所消防安全設備設置標準，應就水霧、泡沫、乾粉、二氧化碳滅火設備等選擇設置之場所，下列場所何者得使用預動式自動撒水設備？",21,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-018",113,"有關泡沫滅火設備泡沫放射試驗判定要領，下列何者與消防安全設備測試報告書規定不同？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-water-chemical-018",112,"乾粉滅火設備使用蓄壓用氣體容器，若氣體使用氮氣時，在溫度 35℃，大氣壓力（表壓力） 0 kg\u002Fcm2 狀態下，除加算清洗配管所需要量外，每一公斤乾粉藥劑需氮氣之量為何？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-water-chemical-018",111,"依各類場所消防安全設備設置標準規定，總樓地板面積 100 平方公尺之何種場所應設置滅火器？ ①咖啡廳 ②幼兒園 ③陳列館 ④商場",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-water-chemical-018",109,"移動式泡沫滅火設備進行綜合檢查作業時，發泡倍率應在幾倍以上？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-water-chemical-018",108,"依各類場所消防安全設備檢修及申報作業基準，固定式泡沫滅火設備（低發泡）綜合檢查，設置泡沫頭者，每次選擇全部放射區域數之若干%以上之放射區域，進行逐區放水試驗，測其放射分布及放射壓力？",1785129972416]