[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-fire-law-036":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-消防法規概要-036","fire-110-1-fire-law-036",110,1,36,"依建築技術規則建築設計施工編規定，夾層係指夾於樓地板與天花板間之樓層；同一樓層內夾層面積之和，超過多少平方公尺，視為另一樓層？",{"A":16,"B":17,"C":18,"D":19},"60","80","100","120","C",null,[],false,"本題考點：建築技術規則建築設計施工編用語定義中「夾層」之面積門檻;《設置標準》第 4 條末項明定，本標準所列建築技術用語適用建築技術規則之用語定義。\n【正解理由】依建築技術規則建築設計施工編建築技術用語定義，夾層係夾於樓地板與天花板間之樓層；同一樓層內夾層面積之和，超過該層樓地板面積三分之一或一百平方公尺者，視為另一樓層。門檻是「三分之一」與「一百平方公尺」兩者之一，題目問的正是面積值，故選 C。\n【逐項排除】\n(A) 六十平方公尺低於法定面積門檻，夾層面積僅六十平方公尺且未超過該層三分之一時，仍併入原樓層計算。\n(B) 八十平方公尺同樣未達門檻；八十之數值常見於《設置標準》第 188 條排煙口設於天花板下方八十公分範圍內，屬長度而非面積。\n(C) 一百平方公尺正是用語定義所明定之面積門檻，超過者該夾層視為另一樓層，為本題應選者。\n(D) 一百二十平方公尺高於法定門檻；一百二十見於《設置標準》第 4 條無開口樓層有效開口「下端距樓地板面一百二十公分以內」,是長度不是面積。\n【記憶點】夾層「三分之一或一百平方公尺」,超過其一即自成一層。","夾層定義的關鍵在「面積之和」與「兩個門檻擇一」:同一樓層內可能有數處夾層，認定時要先加總，再分別檢視是否超過該層樓地板面積三分之一、或超過一百平方公尺，任一成立即視為另一樓層。其立法用意在於，夾層雖非獨立樓層，卻同樣堆放物品、聚集人員並增加火載量，面積達到一定規模後，火災時的避難與搶救難度與正式樓層無異。\n被視為另一樓層在消防上有三重效果：一是樓層數改變,《設置標準》多處以「十一層以上」「第十層以下」作為分界，例如第 29 條緊急電源插座以十一層以上建築物之各樓層為對象；二是樓地板面積改變，第 28 條排煙設備以樓地板面積合計五百平方公尺以上、無開口樓層一千平方公尺以上為門檻；三是總樓地板面積改變，第 24 條緊急照明設備以總樓地板面積一千平方公尺以上建築物之居室為對象。\n易混淆對照：夾層是「夾於樓地板與天花板之間」的水平增設，屋頂突出物則位於屋頂之上，兩者在總樓地板面積都要計入，但只有夾層有「三分之一或一百平方公尺即視為另一樓層」的規定。另可與《設置標準》第 5 條的反向操作併記——同一棟建築物若以無開口且具一小時以上防火時效之牆壁、樓地板區劃分隔，反而「視為另一場所」分別適用本標準：一個是把空間切成兩層，一個是切成兩場所，常被同時命題。另須注意夾層一旦視為另一樓層，建築物之樓層數與各該層樓地板面積都要重新計算，連帶牽動應設設備的判定結果，這正是命題者偏好設計的隱藏轉折。\n記憶數值：夾層看三分之一與一百平方公尺；第 4 條無開口樓層看三十分之一與內切直徑五十公分。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-fire-law-035","某幼兒園經當地消防機關會勘通過依法取得使用執照，依消防安全設備檢修及申報辦法規定，自該使用執照證明文件核發之日期起算，距申報期限在幾個月內，免辦理當次檢修及申報備查？",35,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-fire-law-037","有關二氧化碳滅火設備使用之各種標示規格，下列敘述何者正確？",37,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-fire-law-034","依消防安全設備及必要檢修項目檢修基準規定，室內消防栓設備水帶製造年份超過 10 年應使用耐水壓試驗機，施以 X kgf\u002Fcm2 以上水壓試驗 Y 分鐘合格，始得繼續使用。X＋Y 為多少？",34,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-fire-law-038","依建築技術規則建築設計施工編規定，有關防火門構造等相關規定，下列敘述何者正確？",38,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-fire-law-033","依消防安全設備及必要檢修項目檢修基準規定，有關固定式泡沫滅火設備（低發泡）綜合檢查之檢查方法，下列敘述何者正確？",33,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-fire-law-039","依建築技術規則建築設計施工編規定，有關建築技術用語之定義，下列敘述何者正確？",39,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-036",114,"消防設備人員執行消防安全設備之測試業務，製作測試報告書是由消防安全設備測試人員依滅火設備、警報設備、避難逃生設備、消防搶救上之必要設備及其他經中央主管機關認定之消防安全設備等依序製表，並確認各項消防安全設備之試驗符合規定。下列何者非屬應實施之試驗？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-036",113,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，有關第一類公共危險物品的儲存及處理，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-036",112,"依建築技術規則之定義，自室內經由陽台或排煙室始得進入之安全梯稱為下列何者？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-036",111,"受託辦理檢修之檢修機構應依相關規定檢修完成消防安全設備後，依照消防安全設備檢修及申報辦法規定，應附加檢修完成標示檢修機構專業樣式以何種顏色為底？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-036",109,"依避難器具支固器具及固定部之結構、強度計算及施工方法之規定，裝置避難器具固定部材料，使用直徑 1 公分錨定螺栓，設定試驗荷重 500 公斤力（kgf）時，則鎖緊扭力應為多少公斤力\u002F公分（kgf\u002Fcm）？",1785129969857]