[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-fire-law-029":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-消防法規概要-029","fire-110-1-fire-law-029",110,1,29,"有一室外儲槽，其容量為 9000 公秉，依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，設有防火水幕，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"其設置之緊急電源，應使用發電機設備、蓄電池設備或具有相同效果之引擎動力系統，其供電容量為 160 分鐘","其設置之水源容量，不得小於防護該儲槽連續放水 120 分鐘之水量","防火水幕設備之水源應連結加壓送水裝置，加壓送水裝置啟動後 8 分鐘內應能形成水幕","防火水幕配管於管系竣工時，應做加壓試驗，試驗壓力為加壓送水裝置全閉揚程 2.5 倍以上之水壓，須持續 2 小時無漏水現象","B",null,[],false,"本題考點：室外儲槽設置防火水幕時之水源容量、緊急電源、形成水幕時間與配管加壓試驗，依《防火牆及防火水幕設置基準》。\n【正解理由】該基準第十點第一款明定，儲槽容量未達一萬公秉者，水源容量不得小於防護該儲槽連續放水一百二十分鐘之水量；儲槽容量達一萬公秉以上者，不得小於連續放水二百四十分鐘之水量。本題儲槽為九千公秉，未達一萬公秉，適用一百二十分鐘之級距，故選 B。\n【逐項排除】\n(A) 錯在分鐘數。第九點所定防火水幕設備之緊急電源供電容量，儲槽容量未達一萬公秉者為一百八十分鐘，達一萬公秉以上者為三百六十分鐘，並無一百六十分鐘之級距。\n(B) 與第十點第一款逐字相符，九千公秉落在「未達一萬公秉」該格，為本題應選者。\n(C) 錯在時間。第八點第五款為加壓送水裝置啟動後六分鐘內應能形成水幕，非八分鐘。\n(D) 錯在倍數。第七點第五款為試驗壓力為加壓送水裝置全閉揚程一點五倍以上之水壓，須持續兩小時無漏水現象；持續兩小時寫對了，倍數卻由一點五倍改成二點五倍。\n【記憶點】一萬公秉是分水嶺：水源一百二十對二百四十分鐘、電源一百八十對三百六十分鐘，水幕六分鐘內成形。","防火水幕不是一般的滅火設備，它是「用水簾換距離」的替代措施。該基準第一點載明，係為規範《公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法》第三十七條第二款第一目及第三目所定防火牆及防火水幕之設置基準而訂定；而該辦法第三十七條第二款規定儲存液體儲槽側板外壁與儲存場所廠區之境界線距離應依附表規定，但以不燃材料建造具二小時以上防火時效之防火牆、不易延燒者或設置防火水幕者，不在此限。既然它替代的是實體距離，持續時間自然遠長於一般設備：對照《各類場所消防安全設備設置標準》第三十六條、第三十八條，室內消防栓設備的水源只要二十分鐘、緊急電源三十分鐘，而防火水幕動輒一百二十至三百六十分鐘。\n其餘配套一併記：第八點規定水源應連結加壓送水裝置，加壓送水裝置應採用消防幫浦、應為專用、應連接緊急電源（驅動系統為引擎或渦輪機者免設）、應設在便於檢修且無受火災等災害損害之處，幫浦全揚程 H＝h1＋h2＋h3，即噴頭設計壓力換算成水頭之值、配管摩擦損失水頭與落差之和；第七點規定配管應為專用，乾式配管部分應施予鍍鋅等防腐蝕處理，平時應充滿水，但自開關閥或選擇閥以下至防火水幕噴頭之配管不在此限，開關閥及選擇閥附近配管並應標示防護儲槽編號。\n同屬公共危險物品場所的冷卻撒水設備可作對照：《設置標準》第二百十六條規定，以室內、室外儲槽儲存閃火點在攝氏七十度以下之第四類公共危險物品之顯著滅火困難場所，撒水量按槽壁總防護面積每平方公尺每分鐘二公升以上計算，水源容量在最大一座儲槽連續放水四小時之水量以上，加壓送水裝置啟動後五分鐘以內能有效撒水——「四小時、五分鐘」與防火水幕的「一百二十分鐘、六分鐘」極易互相汙染，必須按設備別分開記。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-fire-law-028","依各類場所消防安全設備設置標準規定，下列場所何者屬於乙類場所？",28,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-fire-law-030","可燃性高壓氣體儲存場所防爆牆分為鋼筋混凝土製、混凝土空心磚製及鋼板製等三種，並應設置於堅固基礎上，強度應能承受可能預料之氣體爆炸衝擊，有關混凝土空心磚製防爆牆之規定，下列敘述何者正確？",30,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-fire-law-027","依各類場所消防安全設備設置標準規定，自動撒水設備得依實際情況需要選擇適當型式設置。但下列何種場所應設開放式？",27,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-fire-law-031","有關標示設備之規定，下列敘述何者正確？",31,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-fire-law-026","依各類場所消防安全設備設置標準規定，裝設火警自動警報設備之建築物，其火警分區劃定，下列敘述何者正確？",26,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-fire-law-032","裝置避難器具之固定部（係指裝設避難器具之樑、柱、樓板等堅固構造或經補強之部分）直接裝置在建築物主要構造部之施工方法，若以金屬膨脹錨定螺栓之施工方法，金屬膨脹錨定螺栓間之間隔，應為埋入深度之幾倍以上？",32,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-029",114,"依各類場所消防安全設備設置標準規定，下列何處所得免設排煙設備？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-029",113,"有關消防安全設備檢修申報之相關規定，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-029",112,"依消防安全設備及必要檢修項目檢修基準之規定，使用加瓦斯試驗器對瓦斯漏氣火警自動警報設備的檢知器進行加瓦斯測試，若某一回路之檢知器數量為 24 個，有關該回路應選取之檢知器檢查數量，下列敘述何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-029",111,"依各類場所消防安全設備設置標準規定，下列何場所之樓地板面積合計未達 1 千平方公尺，得設置水道連結型自動撒水設備或與現行法令同等以上效能之滅火設備？①產後護理之家 ②團體家屋 ③精神護理之家 ④兒童及少年福利機構",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-029",109,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準，有關幫浦性能之規定，全閉揚程應為性能曲線上全揚程之多少以下？",1785129969810]