[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-fire-law-019":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-消防法規概要-019","fire-110-1-fire-law-019",110,1,19,"有一棟建築物高度超過 60 公尺，其連結送水管採用濕式設計，並設中繼幫浦，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"中繼幫浦放水測試時，應從送水口以送水設計壓力送水，並以口徑 21 毫米瞄子在最頂層測試，其放水壓力在每平方公分 6 公斤以上或 0.6 MPa 以上，且放水量在每分鐘 600 公升以上","屋頂水箱有 0.5 立方公尺以上容量，中繼水箱有 2 立方公尺以上","全閉揚程與押入揚程合計在 180 公尺以上時，增設幫浦使串聯運轉","中繼幫浦全揚程在下列計算值以上：全揚程＝消防水帶摩擦損失水頭＋配管摩擦損失水頭＋放水壓力","A",null,[],false,"本題考點：建築物高度超過六十公尺時，連結送水管中繼幫浦的全揚程算式、水箱容量、串聯運轉門檻與放水測試值。\n【正解理由】依《各類場所消防安全設備設置標準》第 183 條第九款，中繼幫浦放水測試「應從送水口以送水設計壓力送水，並以口徑二十一毫米瞄子在最頂層測試，其放水壓力在每平方公分六公斤以上或 0.6MPa 以上，且放水量在每分鐘六百公升以上」，(A) 四項要件與條文逐字相符，故選 A。\n【逐項排除】\n(A) 二十一毫米瞄子、最頂層測試、每平方公分六公斤、每分鐘六百公升四項均與第 183 條第九款一致，正確。\n(B) 同條第五款為「屋頂水箱有零點五立方公尺以上容量，中繼水箱有二點五立方公尺以上」，本項把中繼水箱寫成二立方公尺，容量不足。\n(C) 同條第七款門檻為「全閉揚程與押入揚程合計在一百七十公尺以上時，增設幫浦使串聯運轉」，本項寫一百八十公尺，門檻錯誤。\n(D) 同條第一款算式為「全揚程＝消防水帶摩擦損失水頭＋配管摩擦損失水頭＋落差＋放水壓力」，本項漏列「落差」一項，公式不完整。\n【記憶點】中繼幫浦記 21 毫米、6 公斤、600 公升；水箱 0.5 與 2.5；串聯門檻 170 公尺。","連結送水管屬消防搶救上之必要設備，由消防車自送水口加壓，供消防人員在上層樓面接水帶射水。建築物高度超過六十公尺時，單靠消防車已無法把水穩定送到最頂層，第 183 條因此要求採濕式並設中繼幫浦分段接力。其全揚程算式 H＝h1＋h2＋h3＋60m 中的六十公尺，就是把最頂層所需放水壓力換算成水頭的固定值，與第 184 條送水設計壓力算式結構完全相同，兩條宜一起記。(D) 之所以錯，正是因為把落差項刪掉，等於假設送水口與放水點沒有高差，這在超高層建築物顯然不成立。\n第 183 條其餘各款構成一組完整數值群：中繼幫浦出水量在每分鐘二千四百公升以上；送水口附近設手動啟動裝置及紅色啟動表示燈，但能由防災中心遙控啟動且設有通話裝置者得免設；一次側設出水口、止水閥及壓力調整閥並附設旁通管，二次側設逆止閥、止水閥及送水口；進水側與出水側配管間設旁通管並裝逆止閥；機械室及送水口處設有能與防災中心通話之裝置。\n配管要求則見第 181 條：立管管徑一百毫米以上，建築物高度在五十公尺以下時得與室內消防栓共用立管、支管六十五毫米以上；配管能承受送水設計壓力一點五倍以上之水壓並持續三十分鐘，設有中繼幫浦者，幫浦二次側配管應能承受全閉揚程一點五倍以上之水壓。再配上第 184 條的水量群，連結送水管的考點地圖即告完整。作答順序上，第 183 條以「建築物高度超過六十公尺者」為適用前提，六十公尺以下的建築物根本不生中繼幫浦問題，先讀高度再比對款次，可以省下大半判讀時間。同屬消防搶救上之必要設備的消防專用蓄水池則自成一套數值，第 186 條規定採機械方式引水時，任一採水口至建築物各部分之水平距離在一百公尺以下，出水量與採水口數依水量分為四十立方公尺未滿一千一百公升一個、四十以上一百二十未滿二千二百公升二個、一百二十以上三千三百公升三個，全揚程為 h1＋h2＋15m，切勿與中繼幫浦的數值混用。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-fire-law-018","第一種室內消防栓與室外消防栓之比較，下列敘述何者正確？",18,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-fire-law-020","依法應裝設火警自動警報設備之建築物，其裝設受信總機及探測器等相關規定，下列敘述何者正確？",20,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-fire-law-017","某甲苯儲槽之內容積為 5000 公升，其儲槽上部未設有固定式滅火設備，依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，該儲槽最大容量為多少公升？",17,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-fire-law-021","依各類場所消防安全設備設置標準規定，有關應設置自動撒水設備之場所，其撒水頭之位置規定，下列敘述何者正確？",21,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-fire-law-016","依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，有關六類公共危險物品之分類，下列敘述何者正確？",16,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-fire-law-022","依各類場所消防安全設備設置標準規定，避難器具於開口部與地面之間保有必要下降空間，下列敘述何者正確？",22,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-019",114,"依各類場所消防安全設備設置標準規定，下列何者應就水霧、泡沫、乾粉、二氧化碳滅火設備等選擇設置？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-019",113,"已領有消防設備人員證書並具有 2 年以上消防實務經驗者，應向主管機關提出申請登記及核發執業執照，始得執行業務。有關消防實務經驗，下列何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-019",112,"依各類場所消防安全設備設置標準之規定，各類場所於增建、改建或變更用途時，下列何項消防安全設備適用增建、改建或變更用途前之標準？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-019",111,"依各類場所消防安全設備設置標準第 12 條之場所用途分類，下列何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-019",109,"依可燃性高壓氣體儲存場所防爆牆設置基準之規定，防爆牆長度應超過設置方位儲存場所建築物牆面長度，其牆腳與儲存場所建築物之距離不得少於多少公尺？",1785129969727]