[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-alarm-evacuation-034":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-警報與避難系統消防安全設備概要-034","fire-110-1-alarm-evacuation-034",110,1,34,"依消防安全設備及必要檢修項目檢修基準，救助袋進行開口部外觀檢查時，開口部面積之限制，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"高 80 公分以上，寬 50 公分以上","高 60 公分以上，寬 60 公分以上","高 80 公分以上，寬為救助袋最大寬度以上","高 180 公分以上，寬為救助袋最大寬度以上","B",null,[],false,"本題考點：救助袋開口部之必要開口面積，見《消防安全設備及必要檢修項目檢修基準》第十八章避難器具一、外觀檢查「開口部」判定方法之表 18-2。\n【正解理由】表 18-2 開口部之大小明列救助袋為「高 60cm 以上、寬 60cm 以上」，同項判定方法並要求由地板面至開口部下端之高度應在 150cm 以下、開口部應能容易開關；本題只問開口面積之限制，即高六十公分以上、寬六十公分以上，故選 B。\n【逐項排除】\n(A) 高 80 公分以上、寬 50 公分以上是同表中緩降機、避難梯、避難繩索、滑杆該列的數值（該列另一種寫法為高 100cm 以上、寬 45cm 以上），不是救助袋該列。\n(B) 與表 18-2 救助袋該列逐字相符，為正確選項。\n(C) 高 80 公分以上、寬為最大寬度以上是同表滑台該列之規定，救助袋不適用。\n(D) 高 180 公分以上、寬為最大寬度以上是同表避難橋該列之規定，數值來源與救助袋無關。\n【記憶點】表 18-2 記法：救助袋六十見方、緩降機類八十乘五十、滑台高八十、避難橋高一百八十。","救助袋的開口部規定有兩套互相對應的法源。《各類場所消防安全設備設置標準》第 162 條以表格明定避難器具於開口部應保有之必要開口面積：緩降機、避難梯、避難繩索及滑杆為高八十公分以上、寬五十公分以上，或高一百公分以上、寬四十五公分以上；救助袋為高六十公分以上、寬六十公分以上；滑臺為高八十公分以上、寬為滑臺最大寬度以上；避難橋為高一百八十公分以上、寬為避難橋最大寬度以上。《消防安全設備及必要檢修項目檢修基準》第十八章避難器具外觀檢查的表 18-2 與之逐列相同，檢查時即以此判定，這是設置規定與檢修判定同源的典型例子。\n同一項「開口部」判定方法還有幾個常考點：開口部應無加設固定板、木條等；制動器、門軸轆等應無生鏽，且開口部應能容易開關；打開門、蓋後其制動器應能確實動作，不會因振動、衝擊而鬆開；開口部附近應無書架、展示台等堵塞；由地板面至開口部下端之高度應在 150 公分以下；開口部太高可能形成避難上之障礙時，應設有固定式或半固定式之踏台，且踏台應保持能用之狀態。注意事項並載明開口部大小未符合表 18-2 時，應參照原核准圖說，確認是否與設置時之狀態相同。\n救助袋的其他空間數值同樣成組出現，適合一起背。表 18-3 下降空間：斜降式為救助袋下方及側面，在上端 25 度、下端 35 度方向所圍範圍內，但沿牆面使用時牆面側不在此限；直降式為救助袋與牆壁之間距 30 公分以上（外牆有突出物且突出物距救助袋支固器具裝設處在 3 公尺以上時，應距突出物前端 50 公分以上），並以救助袋中心半徑 1 公尺圓柱形範圍內。表 18-4 下降空地：斜降式為救助袋最下端起 2.5 公尺及中心線左右 1 公尺以上所圍範圍，直降式為下降空間之投影面積。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-alarm-evacuation-033","緩降機在進行綜合檢查之下降試驗時，以測量下降距離及下降時間計算出下降速度，平均下降速度何者正確？",33,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-alarm-evacuation-035","依各類場所消防安全設備設置標準規定，避難指標設於走廊或通道時，自走廊或通道任一點至指標之步行距離在多少公尺以下？",35,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-alarm-evacuation-032","下列有關得免設緊急照明設備之處所，何者錯誤？",32,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-alarm-evacuation-036","某場所第五層需設置排煙設備，樓地板面積為 1200 平方公尺並區分為 450、400 及 350 平方公尺等三個防煙區劃，試問該層排煙機之排煙量最少應為每分鐘多少立方公尺？",36,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-alarm-evacuation-031","一一九火災通報裝置，下列規定何者正確？",31,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-alarm-evacuation-037","下列有關緊急電源插座之設置，何者錯誤？",37,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-034",113,"依據消防安全設備及必要檢修項目檢修基準，針對 119 火災通報裝置本體實施性能檢查，其中以火警自動警報設備連動啟動將一區段蓄積語音送出後，再操作手動啟動裝置，應能再送出蓄積語音，此為下列何種檢查項目？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-034",112,"有關無線電通信輔助設備無線電接頭之外觀試驗，依據無線電通信輔助設備測試報告書判定要領，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-034",111,"二氧化碳滅火系統全區放射的空間，以往造成人員死傷之動作噴發，與防護空間下列因素何者無關？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-034",109,"有關排煙設備綜合檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-034",108,"依各類場所消防安全設備設置標準之規定，下列何種避難器具的開口面積應為高 60 公分以上，寬 60 公分以上？",1785129964117]