[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-alarm-evacuation-022":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-警報與避難系統消防安全設備概要-022","fire-110-1-alarm-evacuation-022",110,1,22,"有一地下 3 層、地上 7 層之建築物，各層樓地板面積為 600 平方公尺，若地下 1 樓發生火警，則火警自動警報設備之鳴動樓層，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"地下 1~2 樓及地面 1~2 樓","地下 1~3 樓及地面 1 樓","地下 1~2 樓及地面 1 樓","地下 1~3 樓及地面 1~2 樓","B",null,[],false,"本題考點：火警自動警報設備分區鳴動時，起火層位於地下層的鳴動範圍如何劃定。\n【正解理由】本建築物地上七層、任一層樓地板面積六百平方公尺，依《各類場所消防安全設備設置標準》第十九條第二款（六層以上十層以下之建築物任何一層樓地板面積在三百平方公尺以上者）應設火警自動警報設備；地下三層加地上七層共十層，總樓地板面積六千平方公尺，屬應採分區鳴動之規模。依同標準關於火警自動警報設備鳴動方式之規定，起火層在地下層時，火煙沿樓梯與管道間往上竄，最先受威脅的是地面層與其他地下層，故鳴動範圍為地面層及地下各層，地上二層以上不同時鳴動。本題起火於地下一樓，鳴動樓層為地下一至三樓及地面一樓，故選 B。\n【逐項排除】\n(A) 地下一至二樓及地面一至二樓：漏掉地下三樓，且多納入地面二樓。\n(B) 地下一至三樓及地面一樓：地下各層全數鳴動再加地面層，與地下層起火之鳴動範圍相符，為正解。\n(C) 地下一至二樓及地面一樓：地面層正確，但地下三樓未納入鳴動範圍。\n(D) 地下一至三樓及地面一至二樓：地下各層正確，但地面二樓不在地下層起火之鳴動範圍內。\n【記憶點】地下層起火，地下各層一起響、地上只響地面層，地下層彼此相通，不分直上直下。","分區鳴動的立法用意是分階段避難。大型建築物若火警一發生就全棟鳴動，所有樓層同時湧向樓梯，反而會塞住避難動線並引發恐慌；先讓受火煙威脅的樓層避難，其餘樓層待命，是分區鳴動的核心。地下層的特性在於煙無處可洩，只能循樓梯、昇降機昇降路與管道間往上竄，所以地下層起火時，同屬地下的各層與最先承接煙流的地面層一起鳴動，是與煙流方向一致的設計。\n與本題相關而可直接引用的條號有兩條。其一是第十九條，該條列出應設火警自動警報設備之場所，第二款為「六層以上十層以下之建築物任何一層樓地板面積在三百平方公尺以上者」，第三款為「十一層以上建築物」，本題地上七層、每層六百平方公尺，落在第二款。其二是第一百十二條的火警分區劃定：每一火警分區不得超過一樓層，並在樓地板面積六百平方公尺以下，但上下二層樓地板面積之和在五百平方公尺以下者，得二層共用一分區；每一分區之任一邊長在五十公尺以下，裝設光電式分離型探測器時邊長得在一百公尺以下；如由主要出入口或直通樓梯出入口能直接觀察該樓層任一角落時，六百平方公尺得增為一千平方公尺；樓梯、斜坡通道、昇降機之昇降路及管道間等場所，在水平距離五十公尺範圍內且其頂層相差在二層以下時得為一火警分區，但應與各層走廊、通道及居室分別設置；樓梯或斜坡通道，垂直距離每四十五公尺以下為一火警分區，地下層部分應為另一火警分區。本題每層恰為六百平方公尺，正好各成一個火警分區，鳴動樓層與火警分區的計算基礎因此一致。\n再往下延伸，依第二十二條，依第十九條或第二十一條設有火警自動警報或瓦斯漏氣火警自動警報設備之建築物，應設置緊急廣播設備；而第一百三十四條規定廣播分區同樣是每一廣播分區不得超過一樓層，室內安全梯或特別安全梯應垂直距離每四十五公尺單獨設定一廣播分區，其地下層部分另設定一廣播分區。火警分區、廣播分區與鳴動樓層是三個不同概念，卻共用「不跨樓層、地下層另計」的思路，這也是本類題最常被交叉命題的地方。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-alarm-evacuation-021","下列有關免設火警探測器之場所，何者錯誤？",21,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-alarm-evacuation-023","依各類場所消防安全設備設置標準，火警探測器之探測區域係指裝置面之四周以淨高 X 公分以上之樑或類似構造體區劃包圍者。偵煙式探測器，其裝置面之四周淨高應為 Y 公分，其中 X 及 Y 分別為：",23,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-alarm-evacuation-020","有關辦公大樓排煙設備之啟動裝置在消防安全設備及必要檢修項目檢修基準之性能及綜合檢查的檢查及判定方法，下列敘述何者錯誤？",20,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-alarm-evacuation-024","差動式分布型探測器採熱電偶式時，下列敘述何者錯誤？",24,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-alarm-evacuation-019","對於設置在地下建築物、地下層及地上層三者之居室的緊急照明燈進行性能檢查，依照消防安全設備及必要檢修項目檢修基準之規定，使用低照度測定用光電管照度計測試，在地面之水平面照度應分別達多少勒克斯（lux）以上？",19,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-alarm-evacuation-025","下列有關火警受信總機之裝置規定，何者錯誤？",25,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-022",113,"某建築物設有火警受信總機 50 回路，竣工時實施性能試驗，於進行受信總機同時動作試驗時，使用常用電源，應將任意 X 回路設定在火警動作狀態；使用預備電源，應將任意 Y 回路設定在火警動作狀態，判定受信總機、主音響裝置、地區音響裝置、附屬裝置等性能應無異常。則 X+Y=？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-022",112,"有關感熱型探測器定溫式（非再用型）性能檢查之選取檢查數量，依據火警自動警報設備檢修基準，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-022",111,"避難器具安裝完成實施性能試驗，針對支固器具進行荷重試驗，緩降機至少應載重 X kg 以上；救助袋應載重 Y kg 以上，試問 X、Y 分別為何？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-022",109,"有關使用瓦斯之場所供各類場所消防安全設備設置標準第 12 條第 5 款第 1 目使用之地下層，其樓地板面積合計 X 平方公尺以上，且其中甲類場所樓地板面積合計 Y 平方公尺以上者，應設置瓦斯漏氣火警自動警報設備，下列何者與該設置標準之規定相同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-022",108,"依照各類場所消防安全設備檢修及申報作業基準之規定，會結露之場所適用的探測器為下列何者？",1785129963986]