[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-alarm-evacuation-017":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-警報與避難系統消防安全設備概要-017","fire-110-1-alarm-evacuation-017",110,1,17,"下列那二種避難器具在性能檢查時，均須對其下降空地附近之支持或固定裝置進行判定？",{"A":16,"B":17,"C":18,"D":19},"斜降式救助袋及直降式救助袋","滑台及直降式救助袋","滑杆及斜降式救助袋","固定收藏型避難梯及滑台","C",null,[],false,"本題考點：避難器具之支持或固定裝置設在下降空地側者，性能檢查時須一併判定。\n【正解理由】依《消防安全設備及必要檢修項目檢修基準》第十八章避難器具之檢查，斜降式救助袋在地上端之程序為「打開要降落袋子之固定環蓋子，把下部支持裝置的張設繩索前端之掛鉤掛在固定環」，再將張設繩索充分拉緊固定，其下部支持裝置與固定環即位於下降空地側，屬性能檢查「支固器具（固定架）及固定部」應判定之對象；滑杆為上下兩端固定之硬質杆體，下端之固定部同樣落在下降空地側。二者均須對下降空地附近之支持或固定裝置判定，故選 C。\n【逐項排除】\n(A) 斜降式救助袋固然設有固定環，但直降式救助袋依同章說明，係「除了斜降式的下部支持裝置及固定環之項目外」比照斜降式檢查，其下降空地側並無支持或固定裝置。\n(B) 直降式救助袋如前述無地面側固定裝置；滑臺之支撐屬本體結構，檢查對象為滑面及兩端，非設於下降空地之固定裝置。\n(C) 滑杆下端之固定部與斜降式救助袋之下部支持裝置、固定環，均位於下降空地側，為本題應選者。\n(D) 固定收藏型避難梯之判定為被收藏之梯柱應能順利展開、下端碰到堅固的地面、梯柱成垂直橫桿成水平，下端僅抵住地面而未設固定裝置；滑臺同 (B) 所述。\n【記憶點】地面端要拴住的，是斜降式救助袋與滑杆。","下降空地是外觀檢查五個周圍狀況項目的最後一格，依表 18-4：斜降式救助袋為救助袋最下端起 2.5m 及中心線左右 1m 以上所圍範圍；直降式救助袋、緩降機、避難梯均為下降空間之投影面積；滑台為滑台前端起 1.5m 及其中心線左右 50cm 所圍面積；避難橋、避難繩索、滑杆則為應無避難障礙之空地。判定上，下降空地應無障礙物，並應有寬一公尺以上之避難上有效通路，通往廣場、道路等；大小未符合表 18-4 時，及多人使用之緩降機，應參照試驗結果報告表，或依是否與設置時之狀態相同判定。《各類場所消防安全設備設置標準》第 165 條所定之下降空地與該表同旨。\n斜降式救助袋之所以在地面端有東西可檢查，是因為它的展開必須靠地上端把張設繩索拉緊：地上檢查者接受引導繩，拉引導繩使袋本體不會卡到窗子或屋簷而下降，打開固定環蓋子，把下部支持裝置的張設繩索前端之掛鉤掛在固定環，將張設繩索末端穿過滑輪之繩索中間，充分拉緊使袋本體的下部出口大約離地面 50 公分至 100 公分，再將繩索固定。收藏時則由地上檢查者放鬆支撐繩索至最大限長度並蓋上固定環蓋子。\n器具分類則見第 10 條：避難逃生設備分為標示設備（出口標示燈、避難方向指示燈、觀眾席引導燈、避難指標）、避難器具（滑臺、避難梯、避難橋、救助袋、緩降機、避難繩索、滑杆及其他避難器具）與緊急照明設備三種。把避難器具七種先背熟，再逐種去記它的操作面積、開口部、下降空間、下降空地，是本章最省力的讀法。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-alarm-evacuation-016","建築物之避難器具設置緩降機時，對其開口部進行外觀檢查之判定，下列何者合格？",16,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-alarm-evacuation-018","下列避難器具架設完成後，進行綜合檢查時，何者應判定不合格？",18,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-alarm-evacuation-015","對空氣管式之差動式分布型探測器進行空氣注入之性能檢查時，下列何種試驗無須量測探測器導通與否？",15,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-alarm-evacuation-019","對於設置在地下建築物、地下層及地上層三者之居室的緊急照明燈進行性能檢查，依照消防安全設備及必要檢修項目檢修基準之規定，使用低照度測定用光電管照度計測試，在地面之水平面照度應分別達多少勒克斯（lux）以上？",19,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-alarm-evacuation-014","對火警自動警報設備二信號式受信總機進行火災表示之性能檢查時，接到第 1 報火警信號但尚未接到第 2 報火警信號時，下列那二種裝置均不應動作？",14,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-alarm-evacuation-020","有關辦公大樓排煙設備之啟動裝置在消防安全設備及必要檢修項目檢修基準之性能及綜合檢查的檢查及判定方法，下列敘述何者錯誤？",20,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-017",113,"電子工業廠房潔淨區，因潔淨環境及構造特殊，特訂定潔淨區消防安全設備設置要點，對於潔淨室設置吸氣式偵煙探測系統時，依據此設置要點，下列說明何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-017",112,"有一地下建築物總樓地板面積超過 1 千平方公尺，依據各類場所消防安全設備設置標準，下列何者非依法應設之消防安全設備？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-017",111,"下列何者非各類場所消防安全設備設置標準明定應設置防災監控系統綜合操作裝置之場所？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-017",109,"一一九火災通報裝置之設置規定，下列敘述何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-017",108,"某商場有一樓層，以防煙垂壁區劃為四區，各區劃樓地板面積分別為 100 平方公尺、300 平方公尺、250 平方公尺、200 平方公尺，採用機械排煙方式，四區劃僅設置 1 台排煙風機，試問該排煙風機之排煙量每分鐘不得小於多少立方公尺？",1785129963944]