[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-alarm-evacuation-014":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-警報與避難系統消防安全設備概要-014","fire-110-1-alarm-evacuation-014",110,1,14,"對火警自動警報設備二信號式受信總機進行火災表示之性能檢查時，接到第 1 報火警信號但尚未接到第 2 報火警信號時，下列那二種裝置均不應動作？",{"A":16,"B":17,"C":18,"D":19},"主音響裝置及地區表示裝置","火災燈及地區表示裝置","主音響裝置及地區音響裝置","火災燈及地區音響裝置","D",null,[],false,"本題考點：二信號式火警受信總機火災表示之性能檢查，第一信號與第二信號各應動作之裝置。\n【正解理由】依《消防安全設備及必要檢修項目檢修基準》第十三章火警自動警報設備之性能檢查，二信號性能之判定方法明定「第一信號時，主音響或副音響裝置應鳴動及地區表示燈應亮燈」「第二信號時，主音響及地區音響裝置應鳴動且火災燈及地區表示燈應亮燈」。可知接到第一報火警信號而尚未接到第二報時，火災燈與地區音響裝置均應保持不動作，故選 D。\n【逐項排除】\n(A) 主音響裝置於第一信號時即應鳴動，地區表示裝置於第一信號時即應亮燈，二者都是應動作者。\n(B) 火災燈固然要到第二信號才亮燈，但地區表示裝置在第一信號時即應亮燈，故非二者均不應動作。\n(C) 地區音響裝置確實要到第二信號才鳴動，但主音響裝置於第一信號時即應鳴動，同樣不符題意。\n(D) 火災燈與地區音響裝置均以第二信號為動作條件，第一報階段二者都不應動作，為本題應選者。\n【記憶點】第一報只給主（副）音響與地區表示燈，火災燈與地區音響等第二報。","二信號式的設計目的，是把「疑似火災」與「確認火災」分成兩階段，先以較小的動靜通知值班人員前往確認，避免單一信號就使全棟鳴動。所以第一信號只讓主音響或副音響鳴動、地區表示燈亮燈，讓人知道哪一分區有異常；要到第二信號才點亮火災燈、使地區音響裝置鳴動，把警報送到現場。同節另規定操作手動報警機時，不論第一信號或第二信號，均應立即進行火災表示，主音響及地區音響裝置應鳴動、火災燈及地區表示燈應亮燈，理由是手動報警代表人已確認火災，沒有再等第二報的必要。\n本章的火災表示試驗分成蓄積式、二信號式與其他三種進行方式，試驗每一回路確認其保持性能後操作復舊開關，再進行下一回路之測試。判定上，各回路之表示窗與編號應對照符合，火災燈、地區表示裝置之亮燈及音響裝置之鳴動應保持性能正常；蓄積式受信機另要求其蓄積之測定時間應在受信機設定之時間加五秒以內。回路導通則以回路斷線試驗確認，試驗用計器之指示值應在所定之範圍，或斷線表示燈亮燈。綜合檢查還有同時動作項目：操作火災試驗開關及回路選擇開關，不要復舊使任意五回路（不滿五回路者，全部回路）進行火災動作表示試驗，受信機含副機應正常動作。\n設置面可對照第 125 條：第六款規定裝置蓄積式探測器或中繼器之火警分區，該分區在受信總機不得有雙信號功能；第七款規定受信總機、中繼器及偵煙式探測器有設定蓄積時間時，其蓄積時間之合計，每一火警分區在六十秒以下，使用其他探測器時在二十秒以下；第九款要求受信總機具有於接受火災信號後一定時間內或再接受火災信號時，強制地區警報音響裝置鳴動之功能。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-alarm-evacuation-013","容易受風影響之場所（如大廳、禮拜堂、大樓頂上之機械室等），依消防安全設備及必要檢修項目檢修基準之規定，可在下列何種探測器中進行選設？",13,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-alarm-evacuation-015","對空氣管式之差動式分布型探測器進行空氣注入之性能檢查時，下列何種試驗無須量測探測器導通與否？",15,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-alarm-evacuation-012","建築物某一樓層（A 區）通往直通樓梯（B 區）的出口標示燈（L）附有誘導音裝置，並設置有停止專用偵煙式探測器（D）及具有緊急廣播設備連動停止性能，在其性能試驗之連動停止試驗中，下列何者應判定不合格？",12,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-alarm-evacuation-016","建築物之避難器具設置緩降機時，對其開口部進行外觀檢查之判定，下列何者合格？",16,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-alarm-evacuation-011","特別安全梯間與緊急昇降機間兼用之排煙室，如設置排煙管道及進風管道，下列何者在綜合試驗中應判定合格？",11,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-alarm-evacuation-017","下列那二種避難器具在性能檢查時，均須對其下降空地附近之支持或固定裝置進行判定？",17,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-014",113,"某社區活動中心位於建築物第 2 層（非避難層），經檢討該活動中心為有開口樓層，依規定自活動中心任一點易於觀察識別其主要出入口，且與主要出入口之步行距離分別在 X 公尺以下，得免設出口標示燈；步行距離在 Y 公尺以下，得免設避難方向指示燈，則 X+Y=？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-014",112,"依各類場所消防安全設備設置標準規定，火警自動警報設備應採分區鳴動，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-014",111,"依各類場所消防安全設備設置標準規定，供失智照顧型長期照顧服務機構、老人福利機構（安養機構）、產後護理機構等避難弱勢場所之樓層，符合規定者得免設避難器具，下列何者非免設之必要條件？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-014",109,"某百貨商場之 5 樓樓地板面積為 2,100 平方公尺，依各類場所消防安全設備設置標準規定，該層樓至少應設置幾個防煙區劃？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-014",108,"緊急照明設備性能試驗之水平面照度測試，切換為緊急電源狀態亮燈，經過 A 分鐘後，使用 B 測試，確認緊急照明燈之照度有無達到法規所規定之值。請問前述 A、B 為何？",1785129963915]