[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-alarm-evacuation-007":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-警報與避難系統消防安全設備概要-007","fire-110-1-alarm-evacuation-007",110,1,7,"下列何種火警探測器在認可作業中須進行粉塵試驗？",{"A":16,"B":17,"C":18,"D":19},"差動式分布型","定溫式局限型","光電式局限型","補償式局限型","C",null,[],false,"本題考點：粉塵試驗係針對偵煙式探測器之認可試驗，四個選項中僅光電式局限型屬偵煙式。\n【正解理由】《各類場所消防安全設備設置標準》第 122 條開宗明義稱「偵煙式探測器除光電式分離型外」並規範其裝置，可知光電式探測器屬偵煙式，其感知原理為煙粒子進入偵煙室後改變光之散射或遮蔽狀態；粉塵與煙同為懸浮微粒，會直接干擾該光學感度，故認可作業須以粉塵試驗驗證其耐粉塵性能。第 120 條所列差動式局限型、補償式局限型、定溫式局限型與第 121 條之差動式分布型，均以熱為感知對象（空氣膨脹或熱電動勢），不以微粒動作，認可作業不進行粉塵試驗，故選 C。\n【逐項排除】\n(A) 差動式分布型：第 121 條規範其空氣管式、熱電偶式、熱半導體式三型，皆屬感熱式；檢修基準表 13-1 且將其列為灰塵、粉末會大量滯留場所之適用探測器。\n(B) 定溫式局限型：第 120 條與差動式、補償式局限型併列之感熱式探測器，以標稱動作溫度動作。\n(C) 光電式局限型：第 122 條所稱之偵煙式探測器，以煙之光學效應動作，須以粉塵試驗確認，為本題應選者。\n(D) 補償式局限型：第 120 條之感熱式探測器，兼具差動與定溫性能，仍非以煙感知。\n【記憶點】粉塵試驗跟著「煙」走，感熱式不做。","探測器的落點看兩件事：感知對象與裝置場所。第 114 條按裝置場所高度分四段選擇種類（未滿四公尺、四公尺以上未滿八公尺、八公尺以上未滿十五公尺、十五公尺以上未滿二十公尺），高度愈高可用種類愈少，十五公尺以上未滿二十公尺僅列離子式局限型一種、光電式局限型一種、光電式分離型一種與火焰式。第 115 條定裝置位置：天花板設有出風口時，除火焰式、差動式分布型及光電式分離型外應距出風口一點五公尺以上；牆上出風口亦為一點五公尺以上，但該出風口距天花板在一公尺以上者不在此限；天花板設排氣口或回風口時，偵煙式探測器應裝置於其周圍一公尺範圍內；局限型探測器以裝置在探測區域中心附近為原則，且不得傾斜四十五度以上（火焰式除外）。偵煙式的專屬規定在第 122 條：探測器下端裝設在裝置面下方六十公分範圍內、距牆壁或樑六十公分以上；有效探測範圍於裝置面高度未滿四公尺時，一種或二種為一百五十平方公尺、三種為五十平方公尺，四公尺以上未滿二十公尺時一種或二種為七十五平方公尺；走廊及通道步行距離每三十公尺至少一個，使用第三種者每二十公尺至少一個。粉塵的影響則見檢修基準火警自動警報設備章表 13-1，灰塵、粉末會大量滯留之場所（垃圾收集場、貨物堆放場、油漆室、紡織與木材石材加工場所等）列為適用差動式分布型、補償式局限型、定溫式與火焰式，並註明設置差動式分布型時其檢出器應有防止塵埃、粉塵侵入之措施、設置補償式局限型時應使用防水型；同章表 13-2 則就有發生誤報或延遲感知之虞處另定選設方式。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-alarm-evacuation-006","緊急廣播設備在樓梯或斜坡通道以外之場所，其設置之揚聲器採性能設計時，在揚聲器標示上如加註下列那二種項目者，該廣播區域內任一點至揚聲器之水平距離方可不受到 10 公尺以下的限制？",6,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-alarm-evacuation-008","下列何組感知線型或分布型探測器在進行外觀試驗時，均須判定其感熱元件之極性有無誤接？",8,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-alarm-evacuation-005","避難方向指示燈之認可作業中，其引導燈具不包括下列何種附加功能？",5,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-alarm-evacuation-009","瓦斯漏氣火警自動警報設備之性能試驗中，下列有關串接配線試驗之測試及判定，何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",9,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-alarm-evacuation-004","有一棟總樓地板面積 4,000 平方公尺的七層辦公建築物，當起火層為地上第二層時，下列有關其火警自動警報設備分區鳴動方式的敘述，何者正確？",4,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-alarm-evacuation-010","各型探測器在性能試驗中，下列有關其動作試驗的動作時間，何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",10,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-007",113,"醫療機構中的 3 樓，經容納病床數量、從業員工與相關區域之樓地板面積等相關條件評估後，其收容人數為 550 人，該樓層在無減設、免設考量下，至少應設多少具避難器具？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-007",112,"有關揚聲器設置場所之外觀試驗判定要領，依據緊急廣播設備測試報告書，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-007",111,"依消防安全設備及必要檢修項目檢修基準，差動式分布型空氣管式之火災動作或動作持續試驗，不動作或測定之時間超過範圍時，應即確認空氣管與旋塞台之連接部位是否栓緊，且應進行何種試驗？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-007",109,"除火焰式探測器外，一般局限型探測器裝設時，依各類場所消防安全設備設置標準之規定，不得傾斜幾度以上？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-007",108,"有關無線電通信輔助設備設置規定，下列何者正確？",1785129963850]