[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-alarm-evacuation-006":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-警報與避難系統消防安全設備概要-006","fire-110-1-alarm-evacuation-006",110,1,6,"緊急廣播設備在樓梯或斜坡通道以外之場所，其設置之揚聲器採性能設計時，在揚聲器標示上如加註下列那二種項目者，該廣播區域內任一點至揚聲器之水平距離方可不受到 10 公尺以下的限制？",{"A":16,"B":17,"C":18,"D":19},"音壓位準及頻率特性","音響功率位準及指向特性區分","音壓位準及指向特性區分","音響功率位準及頻率特性","B",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 133 條第三款以性能設計免除十公尺水平距離限制時，音壓計算式所需之揚聲器標示項目。\n【正解理由】第 133 條第二款第四目定各廣播區域內任一點至揚聲器之水平距離在十公尺以下；同條第三款則規定樓梯或斜坡通道以外之場所，揚聲器之音壓及裝設符合該款規定者，不受前款第四目之限制。該款第一目之計算式Ｐ＝ｐ＋10log10（Ｑ／4πr²＋4(1-α)／Ｓα）中，ｐ為揚聲器音響功率、Ｑ為揚聲器指向係數，二者均屬揚聲器本身特性，須由標示取得；ｒ、α、Ｓ 則為現場條件。故標示須加註音響功率位準與指向特性區分，故選 B。\n【逐項排除】\n(A) 音壓位準及頻率特性：Ｐ（音壓）是依該式求得且須在七十五分貝以上之結果值，非標示提供之輸入；頻率特性不在該式參數之列。\n(B) 音響功率位準及指向特性區分：恰對應該式之ｐ值與Ｑ值，為本題應選者。\n(C) 音壓位準及指向特性區分：指向特性對應Ｑ值無誤，但音壓為待求值，非標示項目。\n(D) 音響功率位準及頻率特性：音響功率對應ｐ值無誤，頻率特性則非該式參數。\n【記憶點】公式裡的ｐ與Ｑ得靠標示提供——音響功率位準加指向特性區分。","第 133 條的體例是「先定音壓、再定裝設、最後給性能設計的替代路徑」。第一款音壓分三級，均為距揚聲器一公尺處所測得：Ｌ級九十二分貝以上、Ｍ級八十七分貝以上九十二分貝未滿、Ｓ級八十四分貝以上八十七分貝未滿。第二款依廣播區域面積配級：超過一百平方公尺設Ｌ級，超過五十平方公尺一百平方公尺以下設Ｌ級或Ｍ級，五十平方公尺以下設Ｌ級、Ｍ級或Ｓ級；第四目定水平距離十公尺以下，並附免設但書（居室樓地板面積在六平方公尺或由居室通往地面之主要走廊及通道樓地板面積在六平方公尺以下、其他非居室部分樓地板面積在三十平方公尺以下，且該區域與相鄰接區域揚聲器之水平距離相距八公尺以下）；第五目則規定設於樓梯或斜坡通道時，至少垂直距離每十五公尺設一個Ｌ級揚聲器。第三款即本題所考的性能設計：樓梯或斜坡通道以外之場所，廣播區域內距樓地板面一公尺處依前開公式求得之音壓在七十五分貝以上者，得不受十公尺之限制；廣播區域之殘響時間在三秒以上時，尚須符合同款第二目以Ｑ、Ｓ、α求得之距離ｒ。相關條文另有第 136 條啟動裝置（各樓層任一點至啟動裝置之步行距離五十公尺以下、設在距樓地板高度零點八公尺以上一點五公尺以下範圍內、第十一層以上各樓層與地下第三層以下各樓層或地下建築物應使用緊急電話方式啟動）與第 137 條（與其他設備共用者，火災時應能遮斷緊急廣播設備以外之廣播）。配線則見第 139 條：導線間及導線對大地間之絕緣電阻值以直流二百五十伏特額定之絕緣電阻計測定，對地電壓在一百五十伏特以下者在零點一ＭΩ以上、超過一百五十伏特者在零點二ＭΩ以上；不得與其他電線共用管槽，但電線管槽內之電線用於六十伏特以下弱電回路者不在此限；任一層之揚聲器或配線短路或斷線時不得影響其他樓層之廣播；設有音量調整器時應為三線式配線。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-alarm-evacuation-005","避難方向指示燈之認可作業中，其引導燈具不包括下列何種附加功能？",5,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-alarm-evacuation-007","下列何種火警探測器在認可作業中須進行粉塵試驗？",7,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-alarm-evacuation-004","有一棟總樓地板面積 4,000 平方公尺的七層辦公建築物，當起火層為地上第二層時，下列有關其火警自動警報設備分區鳴動方式的敘述，何者正確？",4,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-alarm-evacuation-008","下列何組感知線型或分布型探測器在進行外觀試驗時，均須判定其感熱元件之極性有無誤接？",8,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-alarm-evacuation-003","建築物有某一樓層樓地板面積 900 平方公尺且設置之避難方向指示燈均為 C 級，該樓層最有可能為下列何種用途？",3,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-alarm-evacuation-009","瓦斯漏氣火警自動警報設備之性能試驗中，下列有關串接配線試驗之測試及判定，何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",9,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-006",113,"依據各類場所消防安全設備設置標準之規定，避難器具於開口部應保有必要開口面積，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-006",112,"有關室內排煙綜合試驗之排煙風量測試，依據排煙設備測試報告書判定要領，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-006",111,"探測器依其工作原理，下列探測器何者具有搜集環境變異之功能，並採數位通訊方式傳回總機，再由總機根據歷史紀錄來決定是否作動？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-006",109,"差動式局限型探測器進行性能檢查時，使用加熱式試驗器加熱確認動作時間，加熱後到探測器動作應在多少時間以內？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-006",108,"探測器應依裝置場所高度選擇探測器種類裝設，下列何者錯誤？",1785129963842]