[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-water-chemical-034":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-水與化學系統消防安全設備概要-034","fire-109-1-water-chemical-034",109,1,34,"乾粉滅火設備使用加壓或蓄壓用氣體容器，其所使用之氣體為下列何者？",{"A":16,"B":17,"C":18,"D":19},"氮氣或二氧化碳","氬氣或氧氣","空氣或二氧化碳","氮氣或氫氣","A",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 104 條乾粉滅火設備加壓或蓄壓用氣體容器所使用的氣體種類。\n【正解理由】第 104 條第一款明定「加壓或蓄壓用氣體應使用氮氣或二氧化碳」，同條第二款、第三款並分別就氮氣與二氧化碳訂出每一公斤乾粉藥劑所需之量，可見條文承認的氣體恰為這兩種，故選 A。\n【逐項排除】\n(A) 氮氣或二氧化碳：與第 104 條第一款逐字相符。氮氣為惰性且乾燥，不助燃也不使乾粉藥劑受潮固化；二氧化碳本身即滅火藥劑，同樣不助燃，為正確答案。\n(B) 氬氣或氧氣：氧氣是助燃氣體，用來加壓等同對火場供氧，與滅火目的相反；第 104 條第一款所列氣體亦不含氬氣與氧氣。\n(C) 空氣或二氧化碳：空氣含氧且帶水分，乾粉藥劑須維持粉狀、最忌受潮固化，故條文未將空氣列入；二氧化碳雖屬條文所列，但本選項另一半錯誤，整體即為錯誤敘述。\n(D) 氮氣或氫氣：氫氣為可燃氣體，不可能用於滅火設備之加壓或蓄壓；第 104 條第一款亦未列氫氣。\n【記憶點】乾粉的加壓／蓄壓氣體只有兩種：氮氣與二氧化碳——一個是惰性氣體，一個本身就是滅火藥劑。","第 104 條把氣體種類、用量、清洗配管與防震四件事一次規定完，考點密度很高。氣體種類只有氮氣與二氧化碳：氮氣為惰性氣體，不助燃、不與碳酸氫鈉、碳酸氫鉀或磷酸二氫銨等乾粉藥劑起反應，且乾燥不致使藥劑吸濕結塊；二氧化碳本身即滅火藥劑，同樣不助燃，且可液態儲存，單位體積帶的量大、容器體積小。用量規定則要分加壓用與蓄壓用兩軌。加壓用使用氮氣時，在溫度攝氏三十五度、大氣壓力（表壓力）每平方公分零公斤或 0MPa 狀態下，每一公斤乾粉藥劑需氮氣四十公升以上；使用二氧化碳時，每一公斤乾粉藥劑需二氧化碳二十公克並加算清洗配管所需要量以上。蓄壓用使用氮氣時，在同一溫壓狀態下，每一公斤乾粉藥劑需氮氣十公升並加算清洗配管所需要量以上；使用二氧化碳者仍為每一公斤二十公克並加算清洗配管所需要量。加壓用氮氣四十公升、蓄壓用氮氣十公升，差距來自蓄壓式平時已把氣體封存於藥劑桶內，只需補足推送與清洗所需，而加壓式必須在動作瞬間把整桶藥劑加壓推出。條文特別標明攝氏三十五度與表壓力零的基準狀態，是因為氣體體積隨溫度與壓力變動，不指定基準就無從比較用量，這也是常見的觀念型考點。第四款要求清洗配管用氣體另以容器儲存，第五款要求採取有效之防震措施。可與第 88 條對照記憶：二氧化碳滅火設備使用氣體啟動者，啟動用氣體容器能耐每平方公分二百五十公斤或 25MPa 之壓力，內容積應有一公升以上，所儲存之二氧化碳重量在零點六公斤以上且充填比在一點五以上，並不得兼供防護區域之自動關閉裝置使用——同樣是以氣體驅動，但那是啟動用，與乾粉的加壓／蓄壓用途不同，數字不可互串。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-water-chemical-033","加壓式乾粉滅火設備應設壓力調整裝置，其可調整壓力至每平方公分多少公斤以下？",33,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-water-chemical-035","廚房等大量使用火源之處所，多少樓地板面積需有一滅火效能值？",35,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-water-chemical-032","二氧化碳滅火設備採用移動放射方式時，每一具噴射瞄子所需滅火藥劑量在多少公斤以上？",32,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-water-chemical-036","任一消防專用蓄水池至建築物各部分之水平距離不得超過多少公尺？",36,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-water-chemical-031","使用水成膜泡沫液時，樓地板面積每平方公尺之泡沫頭放射量為每分鐘多少公升以上？",31,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-water-chemical-037","連結送水管之配管設置規定，應能承受送水設計壓力 1.5 倍以上之水壓，且能持續多少時間才合格？",37,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-034",113,"蓄壓式鹵化烴滅火藥劑儲存容器使用水平液面計之方法進行滅火藥劑量性能檢查，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-water-chemical-034",112,"有關自動撒水設備免設撒水頭處所得設置補助撒水栓之規定，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-water-chemical-034",111,"第五種滅火設備除滅火器外之其他設備，有關滅火效能值核算之規定，下列何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-water-chemical-034",110,"依消防安全設備及必要檢修項目檢修基準，乾粉加壓式滅火器性能檢查之檢查抽樣頻率，應幾年實施一次性能檢查？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-water-chemical-034",108,"依各類場所消防安全設備設置標準之規定，水霧滅火設備之加壓送水裝置使用消防幫浦時，用於防護電氣設備者，每一個水霧噴頭壓力依規定均應達到多少以上？",1785129972784]