[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-water-chemical-025":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-水與化學系統消防安全設備概要-025","fire-109-1-water-chemical-025",109,1,25,"高架倉庫內所設置之撒水頭，其放水量每分鐘應在多少公升以上？",{"A":16,"B":17,"C":18,"D":19},"100","110","114","124","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 50 條撒水頭放水量的雙軌規定，一般場所與高架倉庫各有一個門檻值。\n【正解理由】第 50 條第一項明定「撒水頭之放水量，每分鐘應在八十公升（設於高架倉庫者，應為一百十四公升）以上，且放水壓力應在每平方公分一公斤以上或 0.1MPa 以上」。括號內的但書正是本題所問：場所屬高架倉庫時，單一撒水頭的放水量門檻由每分鐘 80 公升提高為 114 公升，故選 C。\n【逐項排除】\n(A) 100：每分鐘 100 公升是第 80 條移動式泡沫滅火設備泡沫瞄子的放射量，屬泡沫設備的流量規定，與撒水頭放水量分屬兩套體系，數值不可互借。\n(B) 110：第 50 條全條只出現 80、114、50 三個放水量，並無 110 這一格，是把 114 記成整數的典型誘答。\n(C) 114：與第 50 條括號內「設於高架倉庫者，應為一百十四公升」逐字相符，為正確答案。\n(D) 124：同樣不在第 50 條的數列內，常與第 58 條第三款高架儲存倉庫消防幫浦出水量每分鐘一百三十公升相混，但後者是幫浦出水量的乘算係數，不是單一撒水頭的放水量。\n【記憶點】撒水頭放水量記「一般 80、高架 114、小區劃 50」，倉庫火載量大，數字跟著往上跳。","高架倉庫之所以在第 50 條被單獨拉出一個數字，關鍵在儲存型態：貨架把可燃物堆疊到十公尺以上，火流沿貨架垂直竄升，單靠天花板撒水頭的水滴不易穿過上升熱氣流到達下層貨物，因此放水量必須加大。同一套邏輯貫串《設置標準》對高架儲存倉庫的整組規定，考試也常合併出題。第 17 條第一項第六款規定樓層高度超過十公尺且樓地板面積在七百平方公尺以上之高架儲存倉庫應設自動撒水設備；第 46 條第二項要求設在貨架之撒水頭，任一點至撒水頭之水平距離在二點五公尺以下並以交錯方式設置，儲存棉花類、塑膠類、木製品、紙製品或紡織製品等易燃物品時每四公尺高度至少設置一個，儲存其他物品時每六公尺高度至少一個，儲存之物品會產生撒水障礙時該物品下方亦應設置，並依第 47 條第二項規定設防護板；第 57 條第一款的水源容量表對高架儲存倉庫另立一列，儲存前述易燃物品者快速反應型二十四個、一般反應型三十個，儲存其他物品者為十六個與二十個，遠高於十樓以下建築物「其他」欄的八個與十個；第 58 條第三款則規定消防幫浦出水量以核算之撒水頭數乘以每分鐘九十公升，設於高架儲存倉庫者為一百三十公升，使用小區劃型撒水頭者為六十公升。三組數字排成表最好記：放水量 80／114／50，幫浦係數 90／130／60，水源撒水頭數一般八至十五個、高架十六至三十個。壓力面則要一併記第 50 條的下限（每平方公分一公斤或 0.1MPa 以上）與第 58 條第二項的上限（每平方公分十公斤或 1MPa 以下），換算上每平方公分一公斤約等於 0.1MPa，也約等於十公尺水頭，這是核算幫浦全揚程時反覆用到的換算關係。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-water-chemical-024","室外消防栓設備之水帶箱設置，箱內應配置口徑 63 毫米及長多少公尺之水帶 2 條？",24,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-water-chemical-026","密閉式撒水頭之自動撒水設備末端查驗閥規定，下列何者錯誤？",26,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-water-chemical-023","下列有關室內消防栓箱之敘述，何者正確？",23,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-water-chemical-027","中央消防主管機關認定儲存大量可燃物之場所天花板高度超過 6 公尺，或其他場所天花板高度超過 10 公尺者，應採用何種撒水頭？",27,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-water-chemical-022","室內消防栓之箱面字樣，每字不得小於多少平方公分？",22,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-water-chemical-028","水霧滅火設備之放射區域有 2 區以上者，其主管管徑不得小於多少毫米？",28,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-025",113,"有一建築物樓高 40 m，總樓地板面積 30000 m2，其消防專用蓄水池之有效水量規定要多少立方公尺以上？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-water-chemical-025",112,"有關公共危險物品場所設置室外消防栓之規定，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-water-chemical-025",111,"泡沫試料淨重為 200 g，還原數值如下，則 25%還原時間為何？時間（分） 0 0.5 1 1.5 2 2.5 3 還原量（ml） 0 10 20 30 40 50 60",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-water-chemical-025",110,"自動撒水設備之水源容量規定，若使用側壁型或小區劃型撒水頭時，十層以下樓層在 X 個撒水頭、十一層以上樓層在 Y 個撒水頭繼續放水 20 分鐘之水量以上。X、Y 分別為何？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-water-chemical-025",108,"下列何者不屬於各類場所消防安全設備設置標準第 8 條所規定的滅火設備？",1785129972726]