[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-water-chemical-017":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-水與化學系統消防安全設備概要-017","fire-109-1-water-chemical-017",109,1,17,"某爆竹煙火儲存場所設置室外消防栓設備共 8 具，進行設備檢修綜合檢查時，至少應選擇配管上最遠最高處多少數量之室外消防栓實施放水試驗？",{"A":16,"B":17,"C":18,"D":19},"2具","4具","6具","8具","B",null,[],false,"本題考點：爆竹煙火儲存場所之室外消防栓設備，綜合檢查放水試驗應選取之具數。\n【正解理由】依《各類場所消防安全設備檢修及申報作業基準》室外消防栓設備之綜合檢查，檢查方法明定「選擇配管上最遠最高處之二具室外消防栓做放水試驗。但公共危險物品等場所達顯著滅火困難者、爆竹煙火製造場所有火藥區之作業區或庫存區及爆竹煙火儲存場所超過四具時，選擇配管上最遠最高處之四具室外消防栓做放水試驗」。本題屬爆竹煙火儲存場所且設置 8 具，已超過四具，應取最遠最高處之四具，故選 B。\n【逐項排除】\n(A) 2具是一般場所的原則值，本題場所已落入但書，門檻被提高，不能再用 2 具。\n(B) 4具即但書所定之具數，與原文相符，為應選者。\n(C) 6具不是原文所列的任一數量，屬自行按比例推算之結果。\n(D) 8具是設置具數而非試驗具數；原文要求的是「最遠最高處之四具」，並未要求全部放水。\n【記憶點】室外消防栓放水試驗：一般 2 具；公危與爆竹煙火場所超過四具時取 4 具。","本條檢查之所以選「配管上最遠最高處」，是因為該點的摩擦損失與落差最大，壓力最不利；若最不利點都達標，其餘各點自然合格，這是水系統驗證的通則。判定值同樣分兩套：放水壓力應在 2.5kgf\u002Fcm2 以上 6kgf\u002Fcm2 以下，但公共危險物品等場所達顯著滅火困難者、爆竹煙火製造場所有火藥區之作業區或庫存區及爆竹煙火儲存場所，其放水壓力應在 3.5kgf／cm2 以上；放水量應在 350l\u002Fmin 以上，前述高風險場所則應在 450 l\u002Fmin 以上。放水量以 Ｑ=0.653D2√P 計算（Ｑ 為瞄子放水量 l\u002Fmin、Ｄ 為瞄子口徑 mm、Ｐ 為瞄子壓力 kgf\u002Fcm2），測壓時將壓力表進水口放置於瞄子前端瞄子口徑二分之一距離處讀取指示值。同一份基準的性能檢查在減壓措施項下亦重複同一組判定值，可交叉驗證。\n設置端可對照《各類場所消防安全設備設置標準》第 206-1 條：爆竹煙火製造場所有火藥區之作業區或庫儲區、達中央主管機關所定管制量以上之爆竹煙火儲存及販賣場所，應設置第五種滅火設備；建築物供該等場所使用之樓地板面積合計在一百五十平方公尺以上者，應設置第一種滅火設備之室外消防栓，但販賣場所不在此限。本題「爆竹煙火儲存場所設置室外消防栓」的情境即源於此。\n另可連結第 39 條，室外消防栓設備之配管、試壓及緊急電源準用室內消防栓相關規定，且水平主幹管外露部分應於每二十公尺內以明顯方式標示水流方向及配管名稱；第 41 條，水源容量應在二具室外消防栓同時放水三十分鐘之水量以上。命題方向幾乎都落在「一般值與但書值的對照」，背法條時務必成對記憶。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-water-chemical-016","製造年份超過 10 年之室內消防栓水帶進行耐水壓試驗時，施以 7 kgf\u002Fcm²以上水壓試驗多久時間，始得視為合格可繼續使用？",16,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-water-chemical-018","移動式泡沫滅火設備進行綜合檢查作業時，發泡倍率應在幾倍以上？",18,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-water-chemical-015","公共危險物品室外儲槽場所設置射水設備時，測試之放水壓力應在多少以上？",15,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-water-chemical-019","某室內停車空間設置低發泡固定式泡沫滅火設備，每次檢修作業時，應選擇全部放射區域數多少比例以上之放射區域進行逐區放水試驗，測其放射分布及放射壓力？",19,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-water-chemical-014","測量室內消防栓瞄子直線放水之壓力時，應將壓力表之進水口，放置於瞄子前端多少距離處，讀取壓力表的指示值？",14,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-water-chemical-020","用於防護電氣設施之水霧滅火設備進行放水試驗時，最末端放射區域全部水霧噴頭之放水壓力均應能達到多少壓力以上？",20,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-017",113,"有關冷卻撒水設備測試方法及判定要領，下列何者與消防安全設備測試報告書規定不同？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-water-chemical-017",112,"有關室內消防栓之水平距離、瞄子放水壓力、消防栓及位置之規定，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-water-chemical-017",111,"惰性氣體滅火設備進行綜合檢查時，採低壓式者進行放射試驗時，其放射試驗所需之藥劑量，為該放射區域所設滅火藥劑量之多少以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-water-chemical-017",110,"密閉乾式或預動式之流水檢知裝置二次側配管，為有效排水，支管每 10 公尺傾斜 A 公分，主管每 10 公尺傾斜 B 公分。下列 A，B 何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-water-chemical-017",108,"依各類場所消防安全設備檢修及申報作業基準，有關室內消防栓設備之第一種消防栓水帶及瞄子檢查方法，製造年份超過 10 年或無法辨識製造年份之水帶，應將消防水帶兩端之快速接頭連接於耐水壓試驗機，施以 X kgf\u002Fcm2 以上水壓試驗 Y 分鐘合格，始得繼續使用。則 X+Y 為若干？",1785129972674]