[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-water-chemical-011":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-水與化學系統消防安全設備概要-011","fire-109-1-water-chemical-011",109,1,11,"乾粉滅火設備之緊急電源應為發電機設備或蓄電池設備，其容量應能使該設備有效動作多少時間以上？",{"A":16,"B":17,"C":18,"D":19},"20 分鐘","30 分鐘","60 分鐘","90 分鐘","C",null,[],false,"本題考點：全區及局部放射方式滅火設備之緊急電源容量。\n【正解理由】《各類場所消防安全設備設置標準》第 95 條明定「全區及局部放射方式之緊急電源，應採用自用發電設備或蓄電池設備，其容量應能使該設備有效動作一小時以上」。乾粉滅火設備即以全區或局部放射方式運作，其緊急電源同受此一小時之拘束；一小時換算為 60 分鐘，故選 C。此類設備於停電時仍須完成啟動、遲延、定壓動作與藥劑放射，放射後區域尚須維持管制與表示，故容量要求高於一般水系統設備。\n【逐項排除】\n(A) 20 分鐘是第 155 條出口標示燈及避難方向指示燈緊急電源之一般容量，與本設備無關。\n(B) 30 分鐘為第 38 條室內消防栓設備、第 177 條緊急照明設備之緊急電源容量，是最容易誤選的干擾項。\n(C) 60 分鐘即條文之「一小時以上」，與規定相符，為正解。\n(D) 90 分鐘並非候選條文所定之任何緊急電源容量值。\n【記憶點】全區、局部放射方式的緊急電源＝一小時（60 分鐘）。","緊急電源容量是《設置標準》最典型的橫向比較題，候選條文剛好湊成一組對照：火警自動警報設備第 128 條為蓄電池設備、有效動作十分鐘以上；瓦斯漏氣火警自動警報設備第 145 條為蓄電池設備，二回路有效動作十分鐘以上、其他回路能監視十分鐘以上；室內消防栓設備第 38 條為發電機設備或蓄電池設備、三十分鐘以上；緊急照明設備第 177 條為蓄電池設備三十分鐘以上，採蓄電池設備與緊急發電機併設時，分別為十分鐘及三十分鐘以上；出口標示燈及避難方向指示燈第 155 條為二十分鐘以上，但總樓地板面積五萬平方公尺以上、高層建築物三萬平方公尺以上、地下建築物一千平方公尺以上者之主要避難路徑，該容量應在六十分鐘以上；全區及局部放射方式滅火設備第 95 條則為一小時以上。\n記法可用「用途決定時間」：只負責偵測與報知的警報系統十分鐘；供人員操作滅火或維持照明用的三十分鐘；一次性放射、放射後仍須管制的氣體與乾粉系統一小時。第 155 條的但書則提醒：避難設備的容量會隨場所規模加倍。\n另有三個容易忽略的加成規定，全部落在只適用公共危險物品等場所的編別：第 209 條就室內消防栓設備、第 211 條就自動撒水設備，均規定緊急電源除準用第 38 條外，其供電容量應供有效動作四十五分鐘以上；第 221 條就該類場所之泡沫滅火設備，規定緊急電源除準用第 38 條外，供電容量應在所需放射時間之一點五倍以上。這三條僅適用於公共危險物品或可燃性高壓氣體場所，辦公室、停車場、百貨等一般場所不得援用，命題者很喜歡把兩套數值放在同一組選項裡。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-water-chemical-010","全區放射方式之二氧化碳滅火設備，應設置從啟動裝置動作至二氧化碳放出時間至少多久的遲延裝置？",10,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-water-chemical-012","消防水系統設置呼水裝置時，其溢水用排水管口徑應在多少尺寸以上？",12,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-water-chemical-009","進行低發泡水成膜泡沫放射試驗時，其 25%還原時間應在多久時間以上？",9,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-water-chemical-013","乾粉滅火設備設置啟動用氣體容器時，其容器之內容積應有多少以上？",13,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-water-chemical-008","預動式自動撒水設備竣工測試進行放水試驗時，開放末端查驗閥後，應在多久時間內正常放水？",8,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-water-chemical-014","測量室內消防栓瞄子直線放水之壓力時，應將壓力表之進水口，放置於瞄子前端多少距離處，讀取壓力表的指示值？",14,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-011",113,"室內消防栓進行檢修之綜合檢查，依據消防安全設備及必要檢修項目檢修基準規定，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-water-chemical-011",112,"建築物高度在 X 公尺以下時，其連結送水管得與室內消防栓共用立管，其管徑在 Y 毫米以上，支管管徑在 Z 毫米以上。其中 X、Y 與 Z 分別為多少？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-water-chemical-011",111,"依各類場所消防安全設備設置標準規定，消防專用蓄水池應設置於消防車能接近至多少公尺範圍內，易於抽取處？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-water-chemical-011",110,"室內消防栓設備之加壓送水裝置，若採用壓力水箱方式，則其水箱內空氣不得小於水箱容積的幾分之幾？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-water-chemical-011",108,"二氧化碳滅火設備使用氣體啟動者，啟動用氣體容器之內容積應有 1 公升以上，其所儲存之二氧化碳重量在 0.6 公斤以上，且其充填比應在多少以上？",1785129972640]