[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-fire-science-026":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"火災學概要","fire-science","火災學 · Fire Science","火災學",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-火災學概要-026","fire-109-1-fire-science-026",109,1,26,"閃燃發生時間之影響因素中，通風為其中之一項，請問：A0(H0)1\u002F2 的通風因子公式中，A0 與 H0 各代表何意？",{"A":16,"B":17,"C":18,"D":19},"A0：空間表面積，H0：天花板至地板高度","A0：空間樓地板面積，H0：天花板至地板高度","A0：開口寬度，H0：開口高度","A0：開口面積，H0：開口高度","D",null,[],false,"本題考點：閃燃與最盛期火災的通風因子 A₀√H₀ 中各符號所代表的物理量。\n【正解理由】通風因子來自開口流動的柏努利推導：火場內外因密度差在高度方向產生壓差，流經開口的空氣速度正比於開口高度的平方根，再乘上開口的通流面積，即得體積流率正比於 A₀H₀^(1\u002F2)。式中 A₀ 為開口(通風口)面積，H₀ 為該開口的高度，兩者都描述「洞」而不是描述「房間」，故選 D。\n【逐項排除】\n(A) 錯誤。空間表面積是室內牆面、天花板與地板的總面積，用於熱損失項的計算；天花板至地板高度是室內淨高，兩者都不是開口參數。\n(B) 錯誤。樓地板面積描述空間規模與火載量密度，與流經開口的空氣量無直接關係，代入通風因子會得到錯誤結果。\n(C) 錯誤。只取開口寬度會使量綱變成長度乘長度平方根，寬度僅是面積的一個因子，單獨使用無法表達進氣量。\n(D) 正確。A₀ 為開口面積(m²)、H₀ 為開口高度(m)，通風因子量綱為 m^2.5，是判別火災屬燃料控制或通風控制的關鍵指標。\n【記憶點】通風因子只看洞：洞有多大(面積)、洞有多高(高度開根號)，與房間本身無關。","通風因子的來源是開口流動的柏努利方程式。火場上層熱氣密度小、下層冷空氣密度大，內外密度差在高度方向產生壓差 Δp∝(ρ_a−ρ_g)gh，流經開口的速度 v∝√(2Δp\u002Fρ)∝√h，再乘上開口面積 A₀ 便得到體積流率正比於 A₀√H₀。日本學者川越邦雄由實驗歸納出通風控制階段的空氣流入率約 0.5A₀√H₀ (kg\u002Fs)，木質可燃物的燃燒速率則約為 5.5A₀√H₀ (kg\u002Fmin)，兩式都以通風因子為唯一自變數，這正是它被稱為決定最盛期火災規模之參數的原因。量綱上 A₀ 為 m²、√H₀ 為 m^0.5，通風因子為 m^2.5；選項若給的不是「面積乘高度開根號」，量綱就先對不上，這是最快的排除法。\n\n通風因子也是閃燃判定的核心。McCaffrey、Quintiere 與 Harkleroad 提出的 MQH 關係式把上層煙氣溫升寫成與 Q²\u002F(A₀√H₀·h_k·A_T) 的三分之一次方成正比，其中 A_T 是室內總表面積、h_k 是壁面等效熱傳導係數。命題者刻意把「空間表面積」與「樓地板面積」放進選項，考的就是能否分辨 A_T 與 A₀ 這兩個不同符號：前者管熱損失，後者管進氣量，混用會讓整個閃燃判定失效。由 MQH 式亦可反推閃燃所需熱釋放率的經驗式，同樣以通風因子為主要變數。\n\n易混淆對照與延伸考點：通風因子大時空氣充足，燃燒速率受燃料表面積與熱裂解速率控制，稱燃料控制型；通風因子小時進氣量不足，燃燒速率被空氣量鎖住，稱通風控制型，未燃氣體流出開口在外部續燒，形成開口噴出的火焰，也是迴燃(backdraft)的前置條件。相同火載量的房間，開口愈大燒得愈猛但持續時間愈短、開口愈小則溫度累積慢而延時長。常考的數值操作是：開口高度加倍時通風因子變為原來的 √2 倍，開口面積加倍則通風因子直接加倍。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-fire-science-025","有關火羽流的敘述，下列何者錯誤？",25,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-fire-science-027","下列有關泡沫滅火劑，何者敘述正確？",27,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-fire-science-024","在古蹟及歷史建築物火災風險評估指標中，有關防火因應措施安全評估項目中，不包括下列何項？",24,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-fire-science-028","森林火災的種類與敘述，下列何者正確？",28,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-fire-science-023","若要看清某一物體，該物體與其背景間有一定之對比度。對比度之計算：C=(B\u002FB0)-1，有關對比度下列何者正確？",23,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-fire-science-029","有關防火塗料敘述，下列何者錯誤？",29,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-fire-science-026",113,"有關燃燒上下限之敘述，下列何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-fire-science-026",112,"下列何種靜電災害預防措施旨在防止靜電蓄積，而與其他旨在減少靜電產生的措施有所不同？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-fire-science-026",111,"一公克水完全汽化成水蒸氣，溫度 327℃水蒸氣體積為 V1，溫度 727℃水蒸氣體積為 V2，則 V2\u002FV1 值？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-science-026",110,"易燃性氣體受到壓縮後溫度會有升高的狀況發生，可能會發火導致火災的發生，此現象為何？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-fire-science-026",108,"乙炔加壓後容易產生分解爆炸，為避免此現象，乙炔鋼瓶常利用浸泡何種溶劑之多孔性物質，使乙炔溶解於其中，防止分解爆炸？",1785129967355]