[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-fire-science-010":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"火災學概要","fire-science","火災學 · Fire Science","火災學",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-火災學概要-010","fire-109-1-fire-science-010",109,1,10,"有水之場所的插頭應加裝何種裝置以防止感電發生？",{"A":16,"B":17,"C":18,"D":19},"總開關","延長線","緊急電源","漏電斷路器","D",null,[],false,"本題考點：漏電斷路器的動作原理，以及它在有水場所防止感電的功能定位。\n【正解理由】漏電斷路器內建零相比流器，持續比較進線與回線的電流。正常時兩者大小相等、方向相反，合成磁通為零；一旦人體觸電或設備絕緣劣化，部分電流改經人體或大地回流，進出電流出現差值，零相比流器感測到的不平衡電流達到額定感度電流(常見 15 mA 或 30 mA)時，即在極短時間內跳脫切斷電源，使通過人體的電流與時間乘積低於致命門檻。有水場所人體電阻大幅下降，更需此種保護，故選 D。\n【逐項排除】\n(A) 總開關(無熔絲開關)偵測的是過載與短路造成的過電流，漏電電流通常僅數十毫安培，遠低於其跳脫值，不會動作。\n(B) 延長線只是把電源拉遠，本身不具保護機能，在潮濕場所使用反而增加接點受潮與絕緣劣化的風險。\n(C) 緊急電源是停電時維持消防安全設備運轉的備援電力，解決的是供電中斷問題，與人體感電防護無關。\n(D) 以進出電流差值為判據，在感電造成傷害前切斷電路，正是防止感電的專用裝置，為應選項。\n【記憶點】漏電斷路器看「進出電流差」,總開關看「電流太大」,兩者分工完全不同。","感電的危害程度取決於通過人體的電流大小與持續時間，而非電壓本身。一般以 1 mA 為感知電流、10～16 mA 為脫離電流(超過此值肌肉痙攣而無法自行放手)、約 30～50 mA 持續數秒即可能引起心室顫動而致命。漏電斷路器把額定感度電流設在 30 mA 以下、動作時間 0.1 秒以內，正是要讓電流與時間的乘積落在心室顫動閾值以下。人體電阻在乾燥時可達數千歐姆以上，皮膚潮濕或浸水時會降到數百歐姆，同樣的電壓下電流成倍增加，這就是浴室、廚房、游泳池、戶外插座特別要求裝設的原因。\n動作原理值得與其他保護裝置對照：零相比流器把火線與中性線一起穿過同一鐵心，兩電流相等時磁通抵消、二次側無輸出；漏電時磁通不再抵消，二次側感應電壓推動跳脫線圈。相對地，無熔絲開關靠雙金屬片熱動作(過載)與電磁跳脫(短路);保險絲則靠熔斷。三者保護對象不同，不能互相替代。\n與火災的連結也是常考點：漏電除了造成感電，長期微小漏電流會沿積污、受潮的絕緣表面流動，產生局部碳化與積污導電(tracking),碳化路徑電阻高、發熱集中，最終引燃周邊可燃物，即所謂漏電火災。電氣火災的成因通常整理為短路、過載、接觸不良、半斷線、積污導電、漏電與電氣火花七類，漏電斷路器只能處理其中的漏電一項，無法取代適當的線徑選用與接地。\n延伸考點：接地與漏電斷路器是互補關係，良好接地可讓漏電流迅速回流而促使斷路器動作；若接地不良，漏電流可能只在人體接觸時才成回路，反應會延遲。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-fire-science-008","1 度電為 1,000 瓦．小時（1 kWh），試問 1 度電約等同多少千卡（kcal）？",8,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-fire-science-011","某一線徑 2.0 m\u002Fm 之電線 1 km 長之電阻值為 5.657 Ω，熱阻抗為 378。若周遭溫度為 20℃，當此 10 cm 長之電線通過 10 安培時，其芯線溫度（℃）約為多少？",11,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-fire-science-007","進入石化工廠，車輛會被要求在排氣管加裝滅焰器（flame arrester）以避免火災爆炸之發生，加裝該措施防制火災爆炸之原理為：",7,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-fire-science-012","下列常見之乾粉滅火藥劑敘述何者正確？",12,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-fire-science-006","某次閃電的過程中，雲的底部和地面之間，電壓高達 1 千萬伏特，並在約 0.02 秒內輸送 20 庫倫的電量至地面。下列與閃電有關的敘述何者正確？",6,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-fire-science-013","下列的滅火設備，何者屬於窒息法滅火原理？",13,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-fire-science-010",113,"火場中煙的能見度取決於其濃度，因此裝設避難指示燈的距離攸關逃生可及之視線距離。若某煙層的單位長度光學密度為 0.05（m-1），則裝置其中的避難指示燈能見度應為多少公尺？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-fire-science-010",112,"依據 NFPA（美國防火協會）危險性物品標示，有關「反應性」的敘述，下列何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-fire-science-010",111,"火場當中煙毒危害，下列敘述何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-science-010",110,"甲基乙基酮過氧化物（MEKPO）常用於聚合物的生產，加熱至 100 ℃時會發生爆炸，此化合物屬於那一類公共危險物品？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-fire-science-010",108,"安裝爆炸氣道（或洩爆孔、氣孔）可適度降低侷限空間中粉塵爆炸的危害，則下列敘述何者錯誤？",1785129967247]