[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-fire-law-025":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-消防法規概要-025","fire-109-1-fire-law-025",109,1,25,"依各類場所消防安全設備設置標準之規定，面積 400 坪的知名餐廳，所設置滅火器核算之最低滅火效能值應為多少？",{"A":16,"B":17,"C":18,"D":19},"10","12","14","16","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 31 條第 1 款第 1 目滅火器最低滅火效能值之核算密度，以及坪與平方公尺之換算。\n【正解理由】餐廳屬第 12 條第 1 款之甲類場所，依《設置標準》第 31 條第 1 款第 1 目，供第十二條第一款及第五款使用之場所，各層樓地板面積每一百平方公尺（含未滿）有一滅火效能值。一坪為三點三○五八平方公尺，四百坪即一千三百二十二點三平方公尺，除以一百得十三點二二；條文明定「含未滿」，零頭仍應計一個效能值，進位後為十四，故選 C。\n【逐項排除】\n(A) 10：十個效能值只對應到一千平方公尺，比本題面積短少三百餘平方公尺，屬明顯低估。\n(B) 12：相當於把一坪概估為三平方公尺（一千二百平方公尺）之結果，換算率取得過低，效能值少算兩個。\n(C) 14：以一千三百二十二點三平方公尺、每一百平方公尺（含未滿）一效能值核算所得，與條文相符，為本題應選者。\n(D) 16：相當於把一坪概估為四平方公尺（一千六百平方公尺）之結果，換算率取得過高。\n【記憶點】甲類每一百平方公尺一效能值、含未滿一律進位；坪數先乘三點三○五八再除以一百。","第 31 條第 1 款把最低滅火效能值分成三種核算密度：供第十二條第一款及第五款使用之場所，各層樓地板面積每一百平方公尺（含未滿）有一滅火效能值；供第二款至第四款使用之乙、丙、丁類場所放寬為每二百平方公尺；鍋爐房、廚房等大量使用火源之處所則加密到每二十五平方公尺。密度差異反映用途的火災危險與避難難度，甲類場所人潮密集、避難時間短，要求最嚴；廚房因明火與食用油持續存在，比甲類再加密四倍。餐廳走的是每一百平方公尺這一級。\n「含未滿」三字是本題真正的關鍵：不足一個計算單位的零頭仍計一個效能值，換算後一律無條件進位，不是四捨五入，也不是無條件捨去，所以十三點二二要算成十四而非十三。坪的換算則宜背精確值——一坪為六台尺見方，約一點八一八公尺見方，等於三點三○五八平方公尺；粗估為三或四平方公尺時，答案就會偏成十二或十六，本題四個選項正是照這個誤差光譜排出來的。\n同條其他各款是延伸考點：第二款電影片映演場所放映室及電氣設備使用之處所，每一百平方公尺（含未滿）另設一滅火器；第三款自樓面居室任一點至滅火器之步行距離在二十公尺以下；第四款標識為長邊二十四公分以上、短邊八公分以上之紅底白字。另須與第四編區辨：公共危險物品場所之第五種滅火設備依第 199 條核算，製造或處理場所外牆為防火構造者每一百平方公尺、非防火構造者每五十平方公尺有一效能值，儲存場所則為一百五十與七十五平方公尺，並另有公共危險物品每達管制量之十倍（含未滿）應有一滅火效能值一款。該編僅適用公共危險物品等場所，不得套用於一般餐廳。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-fire-law-024","依各類場所消防安全設備設置標準之規定，有一容納超過 300 人老人福利機構餐廳，其樓地板面積在多少平方公尺以上，廚房排油煙管及煙罩即應裝設簡易自動滅火裝置？",24,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-fire-law-026","原有照護思覺失調患者的康復之家想增設自動滅火設備，如採用小區劃型撒水頭（以第一種感度為限），依各類場所消防安全設備設置標準，其撒水頭間距要在多少公尺以上？",26,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-fire-law-023","依各類場所消防安全設備設置標準，有關一一九火災通報裝置設置之規定，下列敘述何者正確？",23,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-fire-law-027","有一 500 平方公尺地下停車場，採水霧滅火設備，依各類場所消防安全設備設置標準，其水源容量應保持多少立方公尺以上？",27,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-fire-law-022","依各類場所消防安全設備設置標準之規定，二氧化碳滅火設備採全區放射方式時，啟動裝置開關或拉桿開始動作至儲存容器之容器閥開啟，應設有多少秒以上之遲延裝置？",22,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-fire-law-028","依各類場所消防安全設備設置標準，有關裝設瓦斯漏氣火警自動警報設備之規定，下列敘述何者錯誤？",28,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-025",114,"依消防設備人員法規定，有關消防設備人員的業務及責任，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-025",113,"依消防設備人員法規定，消防設備人員執業執照有效期間為幾年？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-025",112,"依各類場所消防安全設備設置標準之規定，應設置火警自動警報設備之場所及設備裝置，下列敘述何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-025",111,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關六類公共危險物品之販賣場所及其位置、構造及設備等規定，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-025",110,"某場所室內高度為 16 公尺，依各類場所消防安全設備設置標準規定，下列何者為可選擇之探測器種類？①定溫式特種 ②差動式分布型 ③光電式局限型一種 ④火焰式",1785129970033]