[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-fire-law-024":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-消防法規概要-024","fire-109-1-fire-law-024",109,1,24,"依各類場所消防安全設備設置標準之規定，有一容納超過 300 人老人福利機構餐廳，其樓地板面積在多少平方公尺以上，廚房排油煙管及煙罩即應裝設簡易自動滅火裝置？",{"A":16,"B":17,"C":18,"D":19},"100","300","500","1000","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 18 條第 2 項所定廚房排油煙管及煙罩應設簡易自動滅火設備之樓地板面積門檻。\n【正解理由】依《設置標準》第 18 條第 2 項，供第 12 條第 1 款第 6 目所定榮譽國民之家、長期照顧服務機構、老人福利機構、護理機構、身心障礙福利機構使用之場所，且樓地板面積合計在五百平方公尺以上者，其廚房排油煙管及煙罩應設簡易自動滅火設備；但已依同條第 1 項設有滅火設備者，得免設。題示為老人福利機構所附設之餐廳，整體歸入第 6 目場所，適用五百平方公尺這一級，故選 C。\n【逐項排除】\n(A) 100：一百平方公尺是第 17 條第 1 項第 2 款「建築物在十一層以上之樓層，樓地板面積在一百平方公尺以上者」應設自動撒水設備之面積，與本項無涉。\n(B) 300：三百平方公尺是同項前段「餐廳」單獨列為應設場所時之起算面積，本題場所歸入老人福利機構一類，須改用五百平方公尺。\n(C) 500：與條文「樓地板面積合計在五百平方公尺以上」相符，為本題應選者。\n(D) 1000：一千平方公尺見於第 17 條第 1 項第 3 款地下層或無開口樓層應設自動撒水設備之面積，非本項門檻。\n【記憶點】獨立餐廳三百、長照老福五百，一過門檻，煙罩與排油煙管就要加簡易自動滅火設備。","第 18 條分兩層規範。第 1 項以表列方式，要求屋頂直昇機停機場、飛機修理廠、汽車修理廠與室內停車空間、昇降機械式停車場、發電機室、鍋爐房與廚房、電信機械室、引擎試驗室等場所，就水霧、泡沫、乾粉、二氧化碳滅火設備擇一設置，其中項目六即為鍋爐房、廚房等大量使用火源之場所，樓地板面積在二百平方公尺以上者。該表備註並定明廚房如設有自動撒水設備，且排油煙管及煙罩設簡易自動滅火設備時，得不受該表限制，可見法規把「煙罩加排油煙管」當成廚房火災的獨立防護對象處理，與廚房本體空間的固定式滅火設備互為補充，重複設置時彼此得免。\n第 2 項才是本題所考的門檻，餐廳以三百平方公尺起算，第 12 條第 1 款第 6 目所定榮譽國民之家、長期照顧服務機構、老人福利機構、護理機構、身心障礙福利機構等場所則以樓地板面積合計五百平方公尺起算，兩個數字互換就是最典型的失分點。題幹「容納超過三百人」只是場所規模的敘述，該項係以樓地板面積為判定基準，並未以容納人數定門檻，作答順序應是先確認場所歸屬哪一款目，再對應面積。\n技術規定接在第 111-1 條：應視排油煙管之斷面積、警戒長度及風速配置感知元件及噴頭，其設置數量、位置及放射量應能有效滅火；排油煙管內風速超過每秒五公尺者，應在警戒長度外側設置放出藥劑之啟動裝置及連動閉鎖閘門，但不設置閘門能有效滅火時不在此限；噴頭之有效射程應涵蓋煙罩及排油煙管，且所設位置不得因藥劑之放射使可燃物有飛散之虞；防護範圍內之噴頭應一齊放射；儲存鋼瓶及加壓氣體鋼瓶設於攝氏四十度以下之位置。所稱警戒長度，指煙罩與排油煙管接合處往內五公尺。面積門檻配技術規定，是這組考點最常見的成對出題方式。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-fire-law-023","依各類場所消防安全設備設置標準，有關一一九火災通報裝置設置之規定，下列敘述何者正確？",23,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-fire-law-025","依各類場所消防安全設備設置標準之規定，面積 400 坪的知名餐廳，所設置滅火器核算之最低滅火效能值應為多少？",25,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-fire-law-022","依各類場所消防安全設備設置標準之規定，二氧化碳滅火設備採全區放射方式時，啟動裝置開關或拉桿開始動作至儲存容器之容器閥開啟，應設有多少秒以上之遲延裝置？",22,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-fire-law-026","原有照護思覺失調患者的康復之家想增設自動滅火設備，如採用小區劃型撒水頭（以第一種感度為限），依各類場所消防安全設備設置標準，其撒水頭間距要在多少公尺以上？",26,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-fire-law-021","依各類場所消防安全設備設置標準，有關使用密閉式撒水頭自動撒水設備末端查驗閥之規定，下列敘述何者正確？",21,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-fire-law-027","有一 500 平方公尺地下停車場，採水霧滅火設備，依各類場所消防安全設備設置標準，其水源容量應保持多少立方公尺以上？",27,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-024",114,"依避難器具支固器具及固定部之結構、強度計算及施工方法規定，有關斜降式救助袋之下部支撐裝置固定在降落面等器具之構造、強度及埋設到降落面之方法，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-024",113,"有關避難器具支固器具及固定部之結構、強度計算及施工方法之規定，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-024",112,"某一消防設備士受託辦理一家辦公大樓消防安全設備檢修，該大樓依規定設置之全部緩降機經消防設備士執行下降檢查，測量每具緩降機之下降距離及下降時間，經計算出之平均下降速度全部符合規定，其緩降機之下降距離及下降時間，下列敘述何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-024",111,"某室外儲槽場所儲槽儲存第四類公共危險物品，儲槽容量合計為 25 萬公秉，防液堤高度應在多少公尺以上？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-024",110,"依各類場所消防安全設備設置標準規定，有關連結送水管之送水設計壓力規定計算，下列敘述何者錯誤？",1785129970028]