[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-fire-law-021":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-消防法規概要-021","fire-109-1-fire-law-021",109,1,21,"依各類場所消防安全設備設置標準，有關使用密閉式撒水頭自動撒水設備末端查驗閥之規定，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"管徑在 25 毫米以上","查驗閥之一次側設有與撒水頭同等放水性能之限流孔","查驗閥二次側設有壓力表","距離地板面之高度在 1 公尺以下，並附有排水管裝置，並標明末端查驗閥字樣","A",null,[],false,"本題考點：使用密閉式撒水頭之自動撒水設備，其末端查驗閥的管徑、壓力表與限流孔的裝設側別，以及距地板面高度。\n【正解理由】依《各類場所消防安全設備設置標準》第 56 條，使用密閉式撒水頭之自動撒水設備末端之查驗閥配置規定為：第一款「管徑在二十五毫米以上」；第二款依各流水檢知裝置配管系統配置，並接裝在建築物各層放水壓力最低之最遠支管末端；第三款「查驗閥之一次側設壓力表，二次側設有與撒水頭同等放水性能之限流孔」；第四款「距離地板面之高度在二點一公尺以下」，並附有排水管裝置，並標明末端查驗閥字樣。選項所述管徑與第一款文字完全相符，故選 A。\n【逐項排除】\n(A) 管徑在 25 毫米以上：與第 56 條第一款一致，敘述正確。\n(B) 一次側設限流孔：第三款所定限流孔在二次側，本選項把一、二次側對調。限流孔的作用是模擬一顆撒水頭的放水性能，必須位於查驗閥開啟後的出水側，才能形成等同一顆撒水頭動作的流量條件。\n(C) 二次側設壓力表：第三款所定壓力表在一次側，用以讀取該配管系統末端原有的放水壓力；改裝於二次側只會量到經限流孔後的壓力，失去查驗意義。\n(D) 高度在 1 公尺以下：第四款明定「二點一公尺以下」，一公尺以下並非條文所定高度；至於附排水管裝置與標明末端查驗閥字樣，則確為同款要求。\n【記憶點】末端查驗閥：管徑二十五毫米以上、一次側壓力表、二次側限流孔、離地板二點一公尺以下。","末端查驗閥是自動撒水設備唯一「不弄濕現場也能驗證全系統」的裝置。把它接在各層放水壓力最低之最遠支管末端（第 56 條第二款），是因為最遠、最低壓處若仍能達到規定放水壓力，其餘位置必然合格；一次側壓力表讀取系統靜態與動態壓力，二次側限流孔則以固定孔徑重現一顆撒水頭的放水量，使流水檢知裝置動作、警報鳴響、加壓送水裝置連動啟動，形成一次完整的模擬火災。\n這條條文要放在自動撒水設備的體系裡記。第 44 條規範配管、配件及屋頂水箱，其中密閉乾式或預動式之流水檢知裝置二次側配管應施予鍍鋅等防腐蝕處理，一齊開放閥二次側配管亦同；為有效排水，支管每十公尺傾斜四公分、主管每十公尺傾斜二公分，並於明顯易見處設排水閥並標明字樣；立管連接屋頂水箱時，水箱容量在一立方公尺以上。第 57 條則規範水源容量，使用密閉式一般反應型、快速反應型撒水頭時，應符合表列個數繼續放水二十分鐘之水量：十一層以上建築物與地下建築物為快速反應型十二個、一般反應型十五個；十層以下建築物中供第十二條第一款第四目使用及複合用途建築物中供該目使用者、地下層同為十二個與十五個，其他場所則為八個與十個；使用側壁型或小區劃型撒水頭時，十層以下八個、十一層以上十二個，同樣放水二十分鐘。\n易混淆的三組概念要分清：其一，一次側與二次側是以流水檢知裝置或查驗閥為界，「一次側」指水源側、「二次側」指撒水頭側；其二，密閉濕式、密閉乾式與預動式的差別在二次側平時是否充水，乾式與預動式才有配管防腐蝕與排水傾斜的要求；其三，密閉式與開放式的水源容量算法不同，開放式是以最大放水區域全部撒水頭放水二十分鐘計算。相關考點還包括第 56 條第四款的「標明末端查驗閥字樣」——同一部標準對測試用出水口（第 34 條第二項第四款）、排水閥（第 44 條第二款）都要求標明字樣，屬於可以一起記的標示型考點。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-fire-law-020","依可燃性高壓氣體儲存場所防護牆設置基準之規定，下列敘述何者正確？",20,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-fire-law-022","依各類場所消防安全設備設置標準之規定，二氧化碳滅火設備採全區放射方式時，啟動裝置開關或拉桿開始動作至儲存容器之容器閥開啟，應設有多少秒以上之遲延裝置？",22,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-fire-law-019","依可燃性高壓氣體儲存場所防爆牆設置基準之規定，防爆牆長度應超過設置方位儲存場所建築物牆面長度，其牆腳與儲存場所建築物之距離不得少於多少公尺？",19,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-fire-law-023","依各類場所消防安全設備設置標準，有關一一九火災通報裝置設置之規定，下列敘述何者正確？",23,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-fire-law-018","有一固態酒精儲槽水平剖面半徑為 10 公尺，依防火牆及防火水幕設置基準，其假想火面高度應為多少公尺？",18,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-fire-law-024","依各類場所消防安全設備設置標準之規定，有一容納超過 300 人老人福利機構餐廳，其樓地板面積在多少平方公尺以上，廚房排油煙管及煙罩即應裝設簡易自動滅火裝置？",24,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-021",114,"某工廠現有建築物及儲存場所之中度危險工作場所樓地板面積合計 2,000 平方公尺，該工廠將擴廠增建一棟一樓層之低度危險工作場所，該增建場所之建築物及儲存場所樓地板面積合計在多少平方公尺以上時，應設置室外消防栓設備？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-021",113,"有關消防設備人員執行業務，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-021",112,"依各類場所消防安全設備設置標準，滅火設備之室內消防栓設備、室外消防栓設備、泡沫滅火設備，及防火牆及防火水幕設置基準之防火水幕設備之水源容量規定，下列敘述何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-021",111,"依建築技術規則建築設計施工編所訂之建築技術用語，下列何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-021",110,"依各類場所消防安全設備設置標準規定，有關應設置自動撒水設備之場所，其撒水頭之位置規定，下列敘述何者正確？",1785129970012]