[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-alarm-evacuation-033":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-警報與避難系統消防安全設備概要-033","fire-109-1-alarm-evacuation-033",109,1,33,"有關緊急電源插座外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"A":16,"B":17,"C":18,"D":19},"保護箱周圍狀況應無檢查上及使用上之障礙物","保護箱外形應無變形、損傷、顯著腐蝕","表示燈應無變形、損傷、脫落、燈泡故障等，且無正常亮燈","開關器應無變形、損傷等，且開關位置應正常","C",null,[],false,"本題考點：《各類場所消防安全設備檢修及申報作業基準》緊急電源插座外觀檢查中，表示燈之判定方法。\n【正解理由】依該基準緊急電源插座之外觀檢查，表示燈以目視確認有無變形、損傷等及是否正常亮燈，其判定方法為「應無變形、損傷、脫落、燈泡故障等，且正常亮燈」。表示燈的作用是顯示該回路帶電可用，平時即應保持亮燈，不亮即代表電源或燈泡異常。選項 C 前半段照抄判定方法，末句卻寫成「且無正常亮燈」，把應予肯定的判定結果反寫成否定，與規定不同，故選 C。\n【逐項排除】\n(A) 與保護箱周圍狀況之判定「應無檢查上及使用上之障礙物」相符；同項另要求箱面應有「緊急電源插座」字樣且字體無污損、不鮮明部分。\n(B) 與保護箱外形之判定「應無變形、損傷、顯著腐蝕」相符，同項並要求箱門可確實正常開、關。\n(C) 表示燈之判定為「且正常亮燈」，本項寫成「且無正常亮燈」，為本題應選者。\n(D) 與開關器之判定「應無變形、損傷等，且開關位置應正常」相符。\n【記憶點】外觀檢查判定句一律「硬體無缺損、功能要正常」：燈要亮、開關位置要正確。","緊急電源插座屬消防搶救上之必要設備，供消防人員於搶救現場取用電源驅動照明與器材，因此外觀檢查的重點全在「消防人員到場後能不能立刻找到、打開、確認可用」。判定項目依序為保護箱之周圍狀況與外形、插座、開關器、表示燈四組：周圍狀況要求應無檢查上及使用上之障礙物，且保護箱面應有「緊急電源插座」之字樣、字體應無污損或不鮮明部分；外形要求應無變形、損傷、顯著腐蝕，且箱門可確實正常開、關；插座依圖示規格判定，單相交流 110V 用者為額定 150V、15A 之接地型插座，三相交流 220V 用者為額定 250V、30A 之接地型插座，並確認應無變形、損傷、顯著腐蝕或異物阻塞；開關器應無變形、損傷等，且開關位置應正常；表示燈應無變形、損傷、脫落、燈泡故障等，且正常亮燈。\n判定方法的句型有規律可循：凡描述硬體狀態者一律用「應無變形、損傷、顯著腐蝕」的否定句，凡描述功能者一律用「應正常」「應能確實」的肯定句。命題者最常用的手法，就是在肯定句前加一個「無」字，或把「正常」改成「不正常」，本題即屬此類；另一種手法是把單相 110V 與三相 220V 的額定值互換。作答時把選項拆成硬體狀態句與功能句兩類，再檢查句尾的肯否定，即可快速命中。\n同一套體例也出現在其他設備的外觀檢查，例如各設備電動機之控制裝置，判定上要求控制盤應設於火災不易波及之位置且周圍無檢查上及使用上之障礙，電壓表指示值應在規定範圍內，未設電壓表者其電源表示燈應亮燈，各開關應無變形、損傷、脫落且開關位置正常——同樣是「燈要亮、位置要對」的肯定判定。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-alarm-evacuation-032","有關無線電通信輔助設備保護箱標示之外觀檢查的判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",32,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-alarm-evacuation-034","有關排煙設備綜合檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",34,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-alarm-evacuation-031","有關緊急照明設備性能檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",31,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-alarm-evacuation-035","有關避難器具開口部周圍狀況外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",35,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-alarm-evacuation-030","有關緊急廣播設備標示燈外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準規定相同？",30,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-alarm-evacuation-036","有關定溫式感知線型探測器之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",36,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-033",113,"某餐廳使用瓦斯燃料，其成分為甲烷（CH4）占 10%、乙烷（C2H6）占 40%、丙烷（C3H8）占 50%，設置有瓦斯漏氣火警自動警報設備。今針對瓦斯漏氣檢知器實施外觀與性能檢查，下列何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-033",112,"依消防安全設備及必要檢修項目檢修基準，在火警自動警報設備性能綜合檢查時，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-033",111,"依消防安全設備測試報告書測試方法及判定要領，有關瓦斯漏氣火警自動警報設備檢知器之動作試驗，以加瓦斯試驗器將試驗瓦斯加進檢知器，測定至瓦斯漏氣表示為止之時間，下列何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-alarm-evacuation-033",110,"緩降機在進行綜合檢查之下降試驗時，以測量下降距離及下降時間計算出下降速度，平均下降速度何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-033",108,"有關 B 級出口標示燈（顯示避難方向符號者）及 B 級避難方向指示燈有效範圍的規定，下列何者正確？",1785129964488]