[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-alarm-evacuation-026":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-警報與避難系統消防安全設備概要-026","fire-109-1-alarm-evacuation-026",109,1,26,"有關緊急廣播設備配線之設置，除依屋內線路裝置規則外，下列何者與各類場所消防安全設備設置標準之規定不同？",{"A":16,"B":17,"C":18,"D":19},"設有音量調整器時，應為三線式配線","導線間及導線對大地間之絕緣電阻值，對地電壓超過 150 伏特者，在 0.1 MΩ 以上","任一層之揚聲器或配線有短路或斷線時，不得影響其他樓層之廣播","不得與其他電線共用管槽。但電線管槽內之電線用於 60 伏特以下之弱電回路者，不在此限","B",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 139 條緊急廣播設備配線之絕緣電阻值級距。\n【正解理由】第 139 條第一款明定，導線間及導線對大地間之絕緣電阻值，以直流二百五十伏特額定之絕緣電阻計測定，對地電壓在一百五十伏特以下者，在零點一ＭΩ以上；對地電壓超過一百五十伏特者，在「零點二ＭΩ」以上。選項 B 把超過 150 伏特這一級的標準寫成 0.1 MΩ，等於把低壓級距的數值套到高壓級距，與條文所定不同，故選 B。\n【逐項排除】\n(A) 與第 139 條第四款「設有音量調整器時，應為三線式配線」相符；三線式才能在火災時越過音量調整器強制全音量廣播。\n(B) 對地電壓超過一百五十伏特者應在零點二ＭΩ以上，本項寫 0.1 MΩ，為本題應選者。\n(C) 與第三款「任一層之揚聲器或配線有短路或斷線時，不得影響其他樓層之廣播」相符。\n(D) 與第二款「不得與其他電線共用管槽。但電線管槽內之電線用於六十伏特以下之弱電回路者，不在此限」相符。\n【記憶點】絕緣電阻依對地電壓分級：一百五十伏特以下 0.1 MΩ，超過者加倍為 0.2 MΩ。","絕緣電阻是本科三部配線條文共用的骨架，值得整批記。第 139 條（緊急廣播設備）與第 127 條（火警自動警報設備）第四款，都以直流二百五十伏特額定之絕緣電阻計測定，級距同為對地電壓一百五十伏特以下在零點一ＭΩ以上、超過一百五十伏特者在零點二ＭΩ以上；第 127 條另就探測器回路規定每一火警分區在零點一ＭΩ以上。第 144 條（瓦斯漏氣火警自動警報設備）級距數值相同，但測定用的是直流五百伏特額定之絕緣電阻計，檢知器回路則為每一警報分區零點一ＭΩ以上。「二百五十伏特對五百伏特」正是這三條最容易被抽換的差異點。\n第 127 條還有兩個常考數值可一併掛上：Ｐ型受信總機採數個分區共用一公用線方式配線時，該公用線供應之分區數不得超過七個；Ｐ型受信總機之探測器回路電阻在五十Ω以下。另該條第五款規定，埋設於屋外或有浸水之虞之配線，採用電纜並穿於金屬管或塑膠導線管，與電力線保持三十公分以上之間距。\n回到第 139 條，第二款的但書「六十伏特以下之弱電回路」是共用管槽的唯一例外，命題者常把伏特數改小或直接刪掉但書；第三款「短路或斷線不得影響其他樓層之廣播」則對應緊急廣播的分區獨立性，避免單一樓層故障癱瘓全棟通報。檢修面上，《各類場所消防安全設備檢修及申報作業基準》配線之性能檢查，係切斷電源確認無充電後以絕緣電阻計測定配線間及配線與大地間之絕緣電阻值，低壓回路每一分岐回路使用五百伏特以下之絕緣電阻計測量，並依配線絕緣阻抗試驗合格判定表所列數值判定，體例與設置標準相互呼應。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-alarm-evacuation-025","有關火焰式探測器之設置，下列何者與各類場所消防安全設備設置標準之規定不同？",25,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-alarm-evacuation-027","有關緩降機支固器具之裝置，下列何者與各類場所消防安全設備設置標準之規定不同？",27,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-alarm-evacuation-024","有關標示設備設在避難出口避難指標之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",24,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-alarm-evacuation-028","有關緊急廣播設備啟動裝置與緊急電話設置場所之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",28,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-alarm-evacuation-023","有關地下建築物總樓地板面積在幾平方公尺以上應設置無線電通信輔助設備，下列何者與各類場所消防安全設備設置標準之規定相同？",23,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-alarm-evacuation-029","有關瓦斯漏氣火警自動警報設備檢知器外觀檢查選取之檢查數量，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",29,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-026",113,"依規定出口標示燈及避難方向指示燈，應保持不熄滅。惟為配合政府機關推動節能減碳措施，除上述燈具採用省電產品外，出口標示燈及走廊通道避難方向指示燈，符合下列何者規定，得予減光或消燈？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-026",112,"依各類場所消防安全設備設置標準規定，醫院在第 3 層樓可以使用下列何種避難器具？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-026",111,"因疫情消毒需求，某醫院院區之一間獨立庫房存放 75%酒精之備用囤放量遽增，下列何因素使該庫房須設置火警自動警報設備移報至火警總機？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-alarm-evacuation-026",110,"對於單相交流 110 V 之緊急電源插座進行外觀及性能檢查時，下列何者與消防安全設備及必要檢修項目檢修基準之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-026",108,"依各類場所消防安全設備設置標準規定，裝置面高度 10 公尺者，不可選擇下列何種探測器設置？",1785129964418]