[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-alarm-evacuation-023":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-警報與避難系統消防安全設備概要-023","fire-109-1-alarm-evacuation-023",109,1,23,"有關地下建築物總樓地板面積在幾平方公尺以上應設置無線電通信輔助設備，下列何者與各類場所消防安全設備設置標準之規定相同？",{"A":16,"B":17,"C":18,"D":19},"1,000","500","300","100","A",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 30 條無線電通信輔助設備之應設場所及其面積門檻。\n【正解理由】第 30 條明定「樓高在一百公尺以上建築物之地下層或總樓地板面積在一千平方公尺以上之地下建築物，應設置無線電通信輔助設備」，其中地下建築物之門檻即為總樓地板面積一千平方公尺以上，故選 A。\n【逐項排除】\n(A) 1,000 平方公尺與第 30 條所定地下建築物門檻相符，為本題應選者。\n(B) 500 平方公尺非第 30 條所定；五百平方公尺是第 28 條第一款排煙設備就第 12 條第一款及第五款第三目場所所定之樓地板面積合計門檻。\n(C) 300 平方公尺非第 30 條所定；三百平方公尺常見於第 19 條火警自動警報設備各款門檻。\n(D) 100 平方公尺非第 30 條所定；一百平方公尺為第 17 條第二款建築物在十一層以上樓層應設自動撒水設備之面積門檻。\n【記憶點】無線電通信輔助設備與連結送水管、緊急電源插座同看「地下建築物一千平方公尺」，另加「樓高一百公尺以上建築物之地下層」。","無線電通信輔助設備列在第 11 條「消防搶救上之必要設備」第五款，與連結送水管、消防專用蓄水池、排煙設備、緊急電源插座並列。這五種設備的服務對象不是場所內的人，而是進入現場的消防人員：地下建築物與超高層建築物的鋼筋混凝土構造會嚴重衰減無線電波，指揮官在地面上無法與深入的攻擊小組通聯，故以洩波同軸電纜或天線把電波導入地下，維持指揮鏈。門檻設計上，第 26 條連結送水管、第 29 條緊急電源插座與第 30 條無線電通信輔助設備都以「總樓地板面積在一千平方公尺以上之地下建築物」為共同門檻，可以一起記；差別在第 26 條另涵蓋五層或六層建築物總樓地板面積六千平方公尺以上者及七層以上建築物，第 29 條另涵蓋十一層以上建築物之各樓層與依建築技術規則應設置之緊急昇降機間，第 30 條另涵蓋樓高一百公尺以上建築物之地下層。注意第 30 條的兩個要件是「或」的關係，任一成立即應設置，且前段用的是「樓高」而非樓層數，這與其他條文慣用的層數判準不同，常被拿來出陷阱題。同屬地下建築物的門檻還有第 15 條第三款室內消防栓設備一百五十平方公尺、第 17 條第七款自動撒水設備一千平方公尺、第 14 條滅火器不論面積一律應設，數值層級不同，需分開記憶。與連結送水管配套的第 180 條則規定出水口設於地下建築物各層或建築物第三層以上各層樓梯間或緊急升降機間等處，各層任一點至出水口之水平距離在五十公尺以下，也是消防搶救上必要設備的常見計算考點。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-alarm-evacuation-022","有關使用瓦斯之場所供各類場所消防安全設備設置標準第 12 條第 5 款第 1 目使用之地下層，其樓地板面積合計 X 平方公尺以上，且其中甲類場所樓地板面積合計 Y 平方公尺以上者，應設置瓦斯漏氣火警自動警報設備，下列何者與該設置標準之規定相同？",22,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-alarm-evacuation-024","有關標示設備設在避難出口避難指標之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",24,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-alarm-evacuation-021","有關應設置火警自動警報設備之場所，下列何者與各類場所消防安全設備設置標準之規定不同？",21,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-alarm-evacuation-025","有關火焰式探測器之設置，下列何者與各類場所消防安全設備設置標準之規定不同？",25,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-alarm-evacuation-020","B 級出口標示燈且有顯示避難方向符號者，其有效距離係指步行至該燈多少公尺之距離？",20,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-alarm-evacuation-026","有關緊急廣播設備配線之設置，除依屋內線路裝置規則外，下列何者與各類場所消防安全設備設置標準之規定不同？",26,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-023",113,"依各類場所消防安全設備設置標準規定，下列何場所或建築物未達應設置火警自動警報設備條件？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-023",112,"有關特別安全梯或緊急昇降機間排煙室之排煙設備，當設置直接面向戶外之窗戶時，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-023",111,"火焰探測器偵測火災為偵測火場的何種參數？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-alarm-evacuation-023",110,"依各類場所消防安全設備設置標準，火警探測器之探測區域係指裝置面之四周以淨高 X 公分以上之樑或類似構造體區劃包圍者。偵煙式探測器，其裝置面之四周淨高應為 Y 公分，其中 X 及 Y 分別為：",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-023",108,"偵煙式局限型探測器裝設於防火構造建築物天花板高度 8 公尺之裝置面時，若樓地板面積為 500 平方公尺，且其天花板中間有一下垂 40 公分的樑隔開，試問至少須設置幾個偵煙式局限型 1 種探測器？",1785129964387]