[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-water-chemical-020":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-水與化學系統消防安全設備概要-020","fire-108-1-water-chemical-020",108,1,20,"公共危險物品等場所之滅火設備分類，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"二氧化碳滅火設備屬第二種滅火設備","乾粉滅火設備屬第三種滅火設備","大型滅火器屬第四種滅火設備","滅火器屬第五種滅火設備","A",null,[],false,"本題考點：公共危險物品等場所滅火設備第一種至第五種的分類歸屬。\n【正解理由】依《各類場所消防安全設備設置標準》第 197 條，公共危險物品等場所之滅火設備分類為：第一種指室內或室外消防栓設備；第二種指自動撒水設備；第三種指水霧、泡沫、二氧化碳或乾粉滅火設備；第四種指大型滅火器；第五種指滅火器、水桶、水槽、乾燥砂、膨脹蛭石或膨脹珍珠岩。二氧化碳滅火設備明列於第三種而非第二種，故選 A。\n【逐項排除】\n(A) 二氧化碳滅火設備與水霧、泡沫、乾粉同屬第三種滅火設備，第二種專指自動撒水設備，本項敘述與條文不符，為本題應選者。\n(B) 乾粉滅火設備確與水霧、泡沫、二氧化碳並列於第三種滅火設備，敘述正確。\n(C) 大型滅火器為第四種滅火設備，其距防護對象任一點之步行距離依第 224 條應在三十公尺以下，敘述正確。\n(D) 滅火器與水桶、水槽、乾燥砂、膨脹蛭石或膨脹珍珠岩同列第五種滅火設備，敘述正確。\n【記憶點】一栓、二撒水、三系統（水霧泡沫二氧化碳乾粉）、四大型、五小型與砂石。","第一種到第五種的分類不只是名詞排序，真正的考點是「哪一級滅火困難場所配哪幾種設備」。依《各類場所消防安全設備設置標準》第四編，顯著滅火困難場所依第 201 條之表設置第一種、第二種或第三種滅火設備：公共危險物品製造場所及一般處理場所可擇一設置，但火災時有充滿濃煙之虞者，不得使用第一種或第三種之移動式滅火設備；室內儲存場所若為高度六公尺以上之一層建築物，限第二種或移動式以外之第三種；室內儲槽場所儲存硫磺者用第三種之水霧滅火設備，儲存閃火點攝氏七十度以上之第四類公共危險物品者，得用水霧、固定式泡沫或移動式以外二氧化碳（或乾粉）滅火設備。一般滅火困難場所依第 202 條設第四種及第五種，其第五種之滅火效能值應在該場所核算之最低滅火效能值五分之一以上；設第四種之場所若已設第一種、第二種或第三種且在有效防護範圍內者，得免設。其他滅火困難場所依第 203 條設第五種，效能值應達核算值以上，但已設第一種至第四種之一且在有效防護範圍內時，得減至五分之一以上；地下儲槽場所應設第五種二具以上。\n距離規定也成組出現：第四種（大型滅火器）距防護對象任一點之步行距離應在三十公尺以下，但與第一種、第二種或第三種滅火設備併設者不在此限（第 224 條）；可燃性高壓氣體儲存場所任一點至滅火器之步行距離在十五公尺以下（第 228 條第四款）；一般場所滅火器則為自樓面居室任一點至滅火器之步行距離在二十公尺以下（第 31 條第三款）。三個距離分屬不同對象，是最常混淆之處。\n此外，可燃性高壓氣體製造場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽另有一套防護設備分類：冷卻撒水設備與射水設備（固定式射水槍、移動式射水槍或室外消防栓）。這套與第一種至第五種滅火設備並列但體系不同，題目若問的是可燃性高壓氣體場所之防護設備，答案不會落在五種滅火設備裡。第 228 條並規定該類場所滅火器每具對普通火災應具有四個以上、對油類火災具有十個以上之滅火效能值。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-water-chemical-019","依各類場所消防安全設備檢修及申報作業基準，有關高壓式二氧化碳滅火藥劑儲存容器之滅火藥劑量檢查方法之注意事項中，鈷 60 有效使用年限約為多少年，如已超過時，應即時連絡專業單位處理或更換？",19,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-water-chemical-021","某鍋爐房樓地板面積為 20 m×15 m，依法其所需之滅火效能值為何？",21,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-water-chemical-018","依各類場所消防安全設備檢修及申報作業基準，固定式泡沫滅火設備（低發泡）綜合檢查，設置泡沫頭者，每次選擇全部放射區域數之若干%以上之放射區域，進行逐區放水試驗，測其放射分布及放射壓力？",18,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-water-chemical-022","有關潔淨藥劑氣體滅火設備滅火藥劑主要成分之敘述，下列何者正確？",22,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-water-chemical-017","依各類場所消防安全設備檢修及申報作業基準，有關室內消防栓設備之第一種消防栓水帶及瞄子檢查方法，製造年份超過 10 年或無法辨識製造年份之水帶，應將消防水帶兩端之快速接頭連接於耐水壓試驗機，施以 X kgf\u002Fcm2 以上水壓試驗 Y 分鐘合格，始得繼續使用。則 X+Y 為若干？",17,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-water-chemical-023","依各類場所消防安全設備設置標準之規定，有關應設置室外消防栓設備之場所，下列敘述何者正確？",23,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-020",113,"有關水道連結型自動撒水設備，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-water-chemical-020",112,"下列何種海龍替代品滅火劑，其熱分解物不至於產生氟化氫（HF）？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-water-chemical-020",111,"電子工業廠房潔淨室設置消防安全設備，下列敘述何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-water-chemical-020",110,"飛機修理廠、飛機庫樓地板面積在 200 平方公尺以上者，可就水霧、泡沫、乾粉、二氧化碳滅火設備等選擇下列何者設置之？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-water-chemical-020",109,"用於防護電氣設施之水霧滅火設備進行放水試驗時，最末端放射區域全部水霧噴頭之放水壓力均應能達到多少壓力以上？",1785129972963]