[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-fire-science-005":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"火災學概要","fire-science","火災學 · Fire Science","火災學",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-火災學概要-005","fire-108-1-fire-science-005",108,1,5,"可燃性液體的閃火點（flash point），是指當其表面蒸氣與空氣混合達燃燒下限時的：",{"A":16,"B":17,"C":18,"D":19},"蒸氣濃度","蒸氣壓力","蒸氣最小發火溫度","液體溫度","D",null,[],false,"本題考點：閃火點（flash point）的定義本體——它量到的是「液體的溫度」，而不是濃度、壓力或自行發火的溫度。\n【正解理由】依燃燒學定義，可燃性液體受熱時表面持續蒸發，當液體本身升到某一溫度，其表面上方蒸氣與空氣的混合濃度恰好到達燃燒（爆炸）下限，此時外加火源即可產生一閃即滅的燃燒，該液體溫度就是閃火點。定義句中「蒸氣與空氣混合達燃燒下限」是成立條件，被定義的物理量則是液體溫度，單位為℃，故選 D。\n【逐項排除】\n(A) 蒸氣濃度是判定閃火點是否成立的條件（須達燃燒下限），但閃火點這個量測值掛的單位是℃，不是體積百分比。\n(B) 蒸氣壓力雖與液溫有一一對應關係，可由蒸氣壓曲線反推閃火點，但定義的主體仍是溫度，壓力只是背後機制。\n(C) 蒸氣最小發火溫度指無外部火源時混合氣自行起火的溫度，屬自燃點範疇，數值遠高於閃火點，且不需火源即可著火。\n(D) 正確。閃火點即「表面蒸氣濃度恰達燃燒下限時的液體溫度」，是可燃性液體危險程度分級與儲存管理的核心指標。\n【記憶點】閃火點是溫度不是濃度；濃度到下限只是條件，答案要填單位是℃的那一個。","閃火點、燃點與自燃點三者常被混為一談，實際上分別對應不同的物理情境。閃火點是表面蒸氣剛達燃燒下限、遇火源一閃即滅時的液溫；燃點（fire point）是蒸氣供應速率足以維持持續燃燒的液溫，通常比閃火點高約 5 至 10℃；自燃點（auto-ignition temperature）則是完全不需外部火源、僅靠環境加熱即自行著火的溫度，數值往往高出數百度。例如汽油閃火點約在零下 40℃、自燃點卻約 280℃，煤油閃火點約 40 至 70℃、自燃點約 220℃，可見兩者無固定比例關係，也不能由一者推另一者。\n量測方式也影響數值：閉杯法（如 Pensky-Martens、Tag 閉杯）把蒸氣封在杯內，濃度容易累積，測得值較低；開杯法（如 Cleveland 開杯）蒸氣會逸散，測得值通常高出數度。危險物品的分類與運輸標示多採閉杯值，因為它較保守、偏安全側。\n閃火點的實用意義在於分級：國內公共危險物品法規即以閃火點作為第四類易燃液體的分級依據，依序區分特殊易燃物與第一、第二、第三、第四石油類，閃火點越低者管制越嚴、儲存數量管制倍數越小。理論上，液體的飽和蒸氣壓與溫度依克勞修斯-克拉貝龍關係呈指數上升，故液溫每上升約 10℃，蒸氣壓可增加數成，這說明為何夏季高溫下原本安全的液體也可能達到閃火點。相關考點包括閃火點與燃點的高低排序、混合可燃氣體以勒沙特列公式求燃燒下限，以及依閃火點判別液體危險等級。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-fire-science-004","今有 A、B 兩種可燃性氣體以 1：1 之體積混合，已知 A、B 之燃燒下限分別為 3.0%、7.0%，若兩者間互不催化亦不反應，則理論上此混合氣體之燃燒下限為若干%？",4,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-fire-science-006","當受熱平面與熱輻射線方向垂直時，其輻射角為 0 度；兩者平行時，輻射角為 90 度。假設輻射源強度不變，當受熱平面由垂直逐漸傾斜，致使輻射角由 0 度增加至 60 度時，該平面所受的輻射熱通量變為原來的若干倍？",6,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-fire-science-003","不同材質與厚度的牆壁或隔熱板，顯示不同的熱傳導效果；此可藉由下列何者估算？",3,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-fire-science-007","下列有關蒸氣爆炸的敘述何者錯誤？",7,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-fire-science-002","各 1 公斤之碳、氫氣、硫分別與氧進行完全燃燒，其理論需氧量分別為 a、b、c 公斤，則：",2,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-fire-science-008","若乙烷的燃燒熱為 350 kcal\u002Fmole，依據 Burgess-Wheeler 法則，下列何者最為接近乙烷的燃燒下限？",8,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-science-005",114,"火災煙毒氣體之危害主要是下列何種氣體？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-science-005",113,"大樓火災常伴隨煙囪效應。所謂煙囪效應是指建築物內部受熱後熱氣流上升，冷空氣由下方填補，使得火災產生的煙霧會快速瀰漫整個建築物的現象。針對以上敘述，下列何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-science-005",112,"鄰二甲苯的閃火點為 157℃，若鄰二甲苯於 157℃時的飽和蒸氣壓為 2.0 mmHg，試求其燃燒下限為何？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-science-005",111,"在苯中置入油酸鎂等金屬鹼，係採取下列何種防止靜電發生的方法？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-science-005",110,"已知乙烷、乙烯、乙炔的發火能量分別為 a、b、c，則 a、b、c 的大小關係為：",1785129967472]