[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-fire-law-028":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-消防法規概要-028","fire-108-1-fire-law-028",108,1,28,"依可燃性高壓氣體儲存場所防爆牆設置基準規定，防爆牆分為鋼筋混凝土製、混凝土空心磚製及鋼板製等三種，並應設置於堅固基礎上，其強度應能承受可能預料之氣體爆炸衝擊。下列有關其構造規定何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"鋼筋混凝土製防爆牆，其厚度應在 150 mm 以上，高度應在 2000 mm 以上","混凝土空心磚製防爆牆，其厚度應在 200 mm 以上，高度應在 2000 mm 以上，3000 mm 以下","鋼板製防爆牆，其厚度應在 6.0 mm 以上，高度應在 2000 mm 以上","防爆牆之端部或隙角部分須用直徑 10 mm 以上鋼筋","D",null,[],false,"本題考點：《可燃性高壓氣體儲存場所防爆牆設置基準》所定三種防爆牆構造的厚度、高度與配筋直徑。\n【正解理由】依內政部函頒《可燃性高壓氣體儲存場所防爆牆設置基準》關於構造之規定，鋼筋混凝土製與混凝土空心磚製防爆牆均以直徑九毫米以上之鋼筋配置，牆之端部或隅角部分亦須以直徑九毫米以上之鋼筋補強。(D) 寫成須用直徑十毫米以上鋼筋，與基準所定的九毫米不符，故選 D。\n【逐項排除】\n(A) 正確。鋼筋混凝土製防爆牆厚度在一百五十毫米以上、高度在二千毫米以上，是三種構造中的基本規格。\n(B) 正確。混凝土空心磚製因磚體有孔隙、整體性較差，厚度提高到二百毫米以上，高度另設二千毫米以上、三千毫米以下的上下限。\n(C) 正確。鋼板製防爆牆以厚度六毫米以上、高度二千毫米以上為規格，並須以鋼骨柱支撐且定著於堅固基礎上。\n(D) 錯誤，為本題應選者。端部與隅角是受爆風時的應力集中處，基準要求以直徑九毫米以上之鋼筋補強，並非十毫米。\n【記憶點】防爆牆記「混凝土一五○、空心磚二○○、鋼板六、高度二○○○、鋼筋九」,單位一律為毫米。","可燃性高壓氣體洩漏後會與空氣形成爆炸性混合氣，一旦引燃就不只是燃燒而是爆炸，產生的爆風壓與飛散物才是主要致災原因。防爆牆的任務因此不是防火而是抗爆：必須設置於堅固基礎上，強度能承受可能預料的氣體爆炸衝擊，並靠配筋維持牆體受衝擊後不整片崩落。端部與隅角之所以另外要求以直徑九毫米以上鋼筋補強，正是因為板狀構造承受面外壓力時，邊界處的彎矩與剪力最大，補強不足就會從角部先破壞。\n\n三種構造各有材料邏輯：鋼筋混凝土製以一百五十毫米實心斷面加縱橫配筋，靠質量與韌性吸收衝擊；混凝土空心磚製斷面不連續，必須加厚到二百毫米，並把高度限制在二千至三千毫米之間，避免高而薄的牆體失穩；鋼板製厚度只要六毫米，靠鋼材的延性與支撐鋼骨柱抵抗變形，但高度同樣不得低於二千毫米。\n\n防爆牆的法律效果是縮減安全距離。依《公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法》第 67 條，可燃性高壓氣體儲存場所與場外保護物之安全距離依儲存面積分級，儲存面積在二十五平方公尺以上者，對第一類保護物為二十二點五公尺、對第二類保護物為十五公尺；設有防爆牆或同等以上防護性能者，得分別縮減為十一點二五公尺與七點五公尺，恰為原距離的一半。同辦法第 73 條另定液化石油氣容器保管室外牆與第一類、第二類保護物之安全距離在八公尺以上，但其外牆牆壁以厚度十五公分以上鋼筋混凝土造構築防爆牆者，安全距離得縮減為一公尺。\n\n記憶上可以把三種構造拆成共通值與差異值：共通值是高度二千毫米以上與配筋直徑九毫米以上，差異值則是厚度一百五十毫米、二百毫米與六毫米。命題者最常動手腳的就是厚度那一組，以及把配筋直徑九毫米改寫成十毫米或十二毫米，本題正是後者。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-fire-law-027","下列有關二氧化碳滅火設備各種標示規格規定之敘述，何者錯誤？",27,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-fire-law-029","依各類場所消防安全設備設置標準，下列有關室內消防栓箱的規定何者錯誤？",29,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-fire-law-026","依防火牆及防火水幕設置基準規定，若防火水幕之防護高度為 12 公尺，請問其每公尺水幕長度放水量應在每分鐘多少公升以上？",26,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-fire-law-030","依各類場所消防安全設備設置標準規定，下列何種處所得免設排煙設備？",30,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-fire-law-025","依防火牆及防火水幕設置基準規定，假想火面高度為將儲槽水平剖面最大直徑乘以規定之數值。當公共危險物品之閃火點未達攝氏 70 度時，應乘以之數值為何？",25,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-fire-law-031","依消防機關辦理建築物消防安全設備審查及查驗作業基準規定，消防安全設備圖說審查及竣工查驗之期限，以受理案件後Ｘ至Ｙ日內結案為原則。但供公眾使用建築物或構造複雜者，得視需要延長，並通知申請人，最長不得超過Ｚ日，請問下列何者正確？",31,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-028",114,"依各類場所消防安全設備設置標準規定，二氧化碳滅火設備全區及局部放射方式之緊急電源，應採用自用發電設備或蓄電池設備，其容量應能使該設備有效動作多少時間以上？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-028",113,"直轄市、縣（市）有登記執業之消防設備師或消防設備士達多少人以上者，得組織消防設備師公會或消防設備士公會？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-028",112,"經濟部輔導未登記工廠申請補辦臨時工廠登記，若該場所消防安全設備業依消防機關辦理建築物消防安全設備審查及查驗作業基準之規定完成測試，且經查驗合格，多久時間免辦理消防安全設備檢修結果申報？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-028",111,"可燃性高壓氣體儲存場所防爆牆，其鋼筋混凝土經過 28 日養生後之抗壓強度（kgf\u002Fcm2），應為多少以上？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-028",110,"依各類場所消防安全設備設置標準規定，下列場所何者屬於乙類場所？",1785129970334]