[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-fire-law-025":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-消防法規概要-025","fire-108-1-fire-law-025",108,1,25,"依防火牆及防火水幕設置基準規定，假想火面高度為將儲槽水平剖面最大直徑乘以規定之數值。當公共危險物品之閃火點未達攝氏 70 度時，應乘以之數值為何？",{"A":16,"B":17,"C":18,"D":19},"0.5","1","1.5","2","C",null,[],false,"本題考點：《防火牆及防火水幕設置基準》中「假想火面高度」的算法，以及閃火點高低所對應的乘算係數。\n【正解理由】依內政部函頒《防火牆及防火水幕設置基準》關於假想火面高度之規定，假想火面高度以儲槽水平剖面最大直徑乘以規定係數求得，係數依儲存物閃火點分兩級：閃火點未達攝氏七十度者乘以一點五，攝氏七十度以上者乘以一。題目所問為閃火點未達攝氏七十度，係數即一點五，故選 C。\n【逐項排除】\n(A) 0.5 會使假想火面高度僅為最大直徑的一半，比槽體本身還矮，防火牆或水幕的防護高度將不足以遮蔽火焰輻射，基準並未採此值。\n(B) 1 是閃火點在攝氏七十度以上時所用的係數，該類物品揮發性低、火焰高度較短；套用到未達七十度的高危險情形會低估火面高度。\n(C) 正確。閃火點未達攝氏七十度者常溫即大量揮發、燃燒速率高，火焰被拉長，故以一點五放大假想火面高度。\n(D) 2 並非基準所定係數，常見誤記來源是把「最大直徑乘一點五」記成「半徑乘二倍」,兩者的基準量與倍數都被換掉了。\n【記憶點】假想火面高度＝最大直徑×係數；未達七十度乘一點五，七十度以上乘一。","防火牆與防火水幕是室外儲槽場所的替代性防護手段：當儲槽側板外壁到廠區境界線的距離不足規定值時，得以不燃材料建造具二小時以上防火時效之防火牆，或設置防火水幕替代，使境界線外的鄰地不致受槽體火災的輻射熱波及。要決定牆要多高、水幕要護多高，前提就是先估出火燒起來會有多高，這正是假想火面高度的用途。\n\n之所以用「儲槽水平剖面最大直徑」當基準量，是因為池火的火焰高度與燃燒面的特徵長度正相關：液面愈大，單位時間蒸發的可燃蒸氣愈多，火羽流愈高。閃火點則決定蒸發的難易——閃火點未達攝氏七十度的物品在常溫即可產生足量可燃蒸氣，火勢發展快、火焰細長，故係數放大到一點五；閃火點攝氏七十度以上者需較高溫度才大量揮發，火焰相對矮胖，係數取一即可。攝氏七十度這個門檻在公共危險物品法規中反覆出現，例如儲槽專用室牆壁材料要求的放寬、儲槽周圍保留空地寬度的分級，都以七十度作為分水嶺，可以一起記。\n\n本基準的三個步驟是連貫的考點：先以最大直徑乘係數得假想火面高度，再據以定出防火牆或防火水幕的防護高度，最後由防護高度換算防火水幕每公尺水幕長度的放水量。三步驟中任何一步的數值都可能單獨命題，而最常被設計成陷阱的，就是把「直徑」偷換成「半徑」,或把係數一點五與二互換——記住基準量是「水平剖面最大直徑」,就不會被牽著走。\n\n命題方向上，本基準可以正向問係數、反向給係數問閃火點級距，也可以給定儲槽直徑要求算出假想火面高度。無論哪一種，關鍵都是先判斷儲存物的閃火點落在攝氏七十度的哪一側，再取對應係數；而閃火點資訊常常藏在題幹的物品名稱裡，例如汽油、甲苯屬閃火點未達七十度者，重油這類第三石油類則在七十度以上，判斷物品分類的能力等於半個答案。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-fire-law-024","依消防法第 6 條及其相關規定，有關住宅用火災警報器下列何者正確？",24,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-fire-law-026","依防火牆及防火水幕設置基準規定，若防火水幕之防護高度為 12 公尺，請問其每公尺水幕長度放水量應在每分鐘多少公升以上？",26,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-fire-law-023","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，下列有關「擋牆」之敘述，何者錯誤？",23,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-fire-law-027","下列有關二氧化碳滅火設備各種標示規格規定之敘述，何者錯誤？",27,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-fire-law-022","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，六類物品製造場所，其外牆或相當於該外牆之設施外側，與廠區外「博物館場所」之安全距離應該為多少公尺以上？",22,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-fire-law-028","依可燃性高壓氣體儲存場所防爆牆設置基準規定，防爆牆分為鋼筋混凝土製、混凝土空心磚製及鋼板製等三種，並應設置於堅固基礎上，其強度應能承受可能預料之氣體爆炸衝擊。下列有關其構造規定何者錯誤？",28,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-025",114,"依消防設備人員法規定，有關消防設備人員的業務及責任，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-025",113,"依消防設備人員法規定，消防設備人員執業執照有效期間為幾年？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-025",112,"依各類場所消防安全設備設置標準之規定，應設置火警自動警報設備之場所及設備裝置，下列敘述何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-025",111,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關六類公共危險物品之販賣場所及其位置、構造及設備等規定，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-025",110,"某場所室內高度為 16 公尺，依各類場所消防安全設備設置標準規定，下列何者為可選擇之探測器種類？①定溫式特種 ②差動式分布型 ③光電式局限型一種 ④火焰式",1785129970312]