[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-fire-law-013":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-消防法規概要-013","fire-108-1-fire-law-013",108,1,13,"依據各類場所消防安全設備設置標準規定，下列何者非自動滅火設備？",{"A":16,"B":17,"C":18,"D":19},"室內消防栓設備","水霧滅火設備","泡沫滅火設備","乾粉滅火設備","A",null,[],false,"本題考點：滅火設備依啟動與放射方式可分為自動與非自動兩群，考的是室內消防栓設備的操作性質。\n【正解理由】依《各類場所消防安全設備設置標準》第 7 條，滅火設備指以水或其他滅火藥劑滅火之器具或設備。其中水霧、泡沫、乾粉等系統，是由探測裝置或感知元件偵知火災後，自動啟動加壓送水（或加壓送藥劑）裝置並經噴頭、放出口放射，過程中不需人員在場操作，屬自動滅火設備。室內消防栓設備則必須由人員開啟消防栓箱、拉出水帶、接上瞄子、啟動加壓送水裝置後才能對火點射水，屬人力操作之滅火設備，不具自動放射能力，故選 A。\n【逐項排除】\n(A) 室內消防栓設備須靠人員取用水帶與瞄子放水，火災時無人操作即無法動作，並非自動滅火設備，為本題應選者。\n(B) 水霧滅火設備於自動啟動裝置動作後，經一齊開放閥使水霧噴頭同時放射霧狀水滴，屬自動放射之滅火設備。\n(C) 泡沫滅火設備偵知火災後自動啟動，由泡沫原液與水混合成泡沫水溶液，再經泡沫噴頭或放出口放射，同屬自動。\n(D) 乾粉滅火設備藉加壓氣體將乾粉藥劑經配管自噴頭放出，啟動後自動完成放射程序，仍屬自動滅火設備。\n【記憶點】要人拉水帶的就不是自動——室內消防栓靠人，水霧、泡沫、乾粉靠系統。","《設置標準》第 7 條把各類場所消防安全設備分為滅火設備、警報設備、避難逃生設備、消防搶救上之必要設備，以及其他經中央主管機關認定之消防安全設備五大類，其中滅火設備的定義是「以水或其他滅火藥劑滅火之器具或設備」。這個定義只界定「用什麼滅火」，並未界定「由誰啟動」，因此考題再依啟動方式把滅火設備切成兩群：需人員持械操作者（滅火器、消防砂、室內消防栓、室外消防栓），與偵知火災後自行放射者（自動撒水、水霧、泡沫、二氧化碳、乾粉等）。命題者最愛把兩群混在同一題，要求挑出「非自動」的那一個。\n\n判斷訣竅是看「火災與放射之間有沒有人」。自動系統的共同結構是：偵知（探測器、密閉型撒水頭之感熱元件、火焰偵知裝置）→ 啟動（一齊開放閥、選擇閥、控制盤）→ 放射（噴頭或放出口）。室內消防栓的結構則是：人員發現火災 → 開箱取水帶接瞄子 → 按啟動按鈕使加壓送水裝置運轉 → 人持瞄子射水，每一步都靠人，因此縱使幫浦是自動啟動的，整體仍屬人力操作設備。\n\n易混淆概念對照有三組。其一，自動撒水設備雖名為自動，但密閉型撒水頭是靠感熱元件熔解或玻璃球破裂而放水，屬機械感熱式自動，與由探測器電氣啟動者原理不同。其二，室內消防栓的第一種與第二種，差別在瞄子、水帶型式與操作人數，兩者都是人力操作，不會因為單人可操作就升格為自動設備。其三，二氧化碳等藥劑系統雖設有手動啟動裝置，但手動只是備援手段，本質仍是自動放射系統。\n\n延伸考點：同一觀念會改問「下列何者屬人力操作之滅火設備」「何種滅火設備無須設置探測裝置」，也常與各設備之放射區域、藥劑種類合併命題。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-fire-law-012","依據各類場所消防安全設備設置標準規定，設於儲槽之固定式泡沫滅火設備，下列何者係指供固定頂儲槽槽底注入泡沫法之放出口？",12,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-fire-law-014","建築物間設有過廊，若符合規定者，則可視為另一場所，下列規定何者錯誤？",14,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-fire-law-011","消防設備師及消防設備士參加與消防安全設備設計、監造、裝置及檢修相關技術研討活動之積分證明，下列項目中何者非以每小時積分 10 分累計？",11,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-fire-law-015","各類場所於增建、改建或變更用途時，其消防安全設備之設置，下列何者非適用增建、改建或變更用途後之標準？",15,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-fire-law-010","依消防機關辦理建築物消防安全設備審查及查驗作業基準規定，下列有關建築物消防安全設備竣工查驗程序何者錯誤？",10,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-fire-law-016","依據各類場所消防安全設備設置標準，防災中心之位置與構造，下列規定何者錯誤？",16,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-013",114,"消防設備人員執行消防安全設備之設計、監造、測試及檢修業務，由消防安全設備設計人員依滅火設備、警報設備、避難逃生設備、消防搶救上之必要設備及其他經中央主管機關認定之消防安全設備等依序繪製，標示記號，並依消防或建築等圖示範例註記，上述製作之文書為下列何者？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-013",113,"依據消防法第 13 條第 1 項規定，一定規模以上之建築物，應由管理權人遴用防火管理人，責其訂定消防防護計畫，下列何者不屬於一定規模以上之建築物？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-013",112,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，室內儲存場所儲存六類公共危險物品之數量，未達管制量 50 倍，且高度在 6 公尺以下者，其位置、構造及設備等規定，下列敘述何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-013",111,"某建築物設置收納金屬製避難梯為避難器具，其升降口之施工方法何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-013",110,"室外儲槽場所之儲槽儲存第四類公共危險物品者，有關防液堤之規定，下列敘述何者正確？",1785129970232]