[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-alarm-evacuation-029":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-警報與避難系統消防安全設備概要-029","fire-108-1-alarm-evacuation-029",108,1,29,"消防安全設備測試報告書測試方法及判定要領中規定，火警自動警報設備外觀試驗，其定溫式感知線型探測器之判定要領中，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"感知線應設置在裝置面下方 0.4 m 以內","感知線之彎曲半徑應在 0.05 m 以上","感知線之安裝在直線部分以每 1 m（如有下垂之虞時，則為 0.5 m）以內之間隔固定","感知線之安裝在彎曲部分以每 0.5 m 以內之間隔固定","B",null,[],false,"本題考點：《消防安全設備測試報告書測試方法及判定要領》火警自動警報設備外觀試驗中，定溫式感知線型探測器的判定項目——裝設高度、彎曲半徑與固定間隔三組數值。\n【正解理由】感知線型探測器是把線狀感熱元件沿裝置面拉設，判定要領的檢查點因此集中在「線怎麼拉、怎麼固定、可以彎多急」。其中彎曲半徑之下限為 0.05 公尺以上：彎折半徑過小會擠壓線內絕緣物、改變其熔融短路的動作特性，甚至造成假動作或不動作，故要領以 0.05 公尺為底線，選項 B 與此相符，故選 B。該判定要領未在候選條文之列，以下僅就項目層級說明。\n【逐項排除】\n(A) 感熱式探測器裝設高度之體例為裝置面下方 0.3 公尺以內——《設置標準》第 120 條第一款就定溫式局限型即明定「探測器下端，裝設在裝置面下方三十公分範圍內」；選項寫 0.4 公尺已逾此範圍。\n(B) 彎曲半徑 0.05 公尺以上，與判定要領所定之下限相符，為本題應選者。\n(C) 直線部分之固定間隔，該要領所定較 1 公尺為密，選項把間隔放寬約一倍，有下垂之虞時之加密值亦同步放寬。\n(D) 彎曲部分線體受力較大、易鬆脫下垂，固定間隔應較直線部分更密；選項所列 0.5 公尺與直線部分同量級，未反映加密要求。\n【記憶點】感知線記三件事：裝置面下方 0.3 公尺級距、彎曲半徑 0.05 公尺以上、固定間隔直線疏彎曲密。","定溫式感知線型探測器與定溫式局限型的差別在感測元件的形狀：局限型是一顆感測本體監視一塊有效探測範圍，感知線型則是一條可沿設備、電纜架、輸送帶敷設的線，線內兩導體以受熱會軟化的絕緣物隔開，達標稱動作溫度時絕緣物熔融使兩導體短路而發出信號，屬非再用型者動作後該段即須更換。因為它是「線」，安裝品質決定性能，判定要領才會把裝設高度、彎曲半徑與固定間隔列為外觀試驗的核心項目。\n同屬線狀元件的差動式分布型空氣管式，《設置標準》第 121 條第一款的規定可以拿來對照理解為何要管這些細節：每一探測區域內之空氣管長度，露出部分應在二十公尺以上；裝接於一個檢出器之空氣管長度在一百公尺以下；空氣管裝置在裝置面下方三十公分範圍內；空氣管裝置在自裝置面任一邊起一點五公尺以內之位置，其間距在防火構造建築物為九公尺以下、其他建築物為六公尺以下。可以看出線狀元件的四類限制完全同構——有效長度下限、單一檢出器的長度上限、離裝置面的垂直距離、以及固定與間距，感知線型的判定要領走的是同一套邏輯。\n第 120 條的局限型規定則是本題選項(A)的判斷依據，並附帶兩個常考數值群：防火構造建築物、裝置面高度未滿四公尺時，定溫式特種有效探測範圍 70 平方公尺、一種 60、二種 20 平方公尺；四公尺以上未滿八公尺時特種 35、一種 30，二種已不適用。第三款則要求具定溫式性能之探測器應裝設在平時最高周圍溫度比其標稱動作溫度低攝氏二十度以上處，具二種以上標稱動作溫度者以最低者為準——感知線型設於鍋爐房、廚房排氣管路等高溫處時，這一條同樣是選型的關鍵。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-alarm-evacuation-028","有關緊急廣播設備之敘述，下列何者錯誤？",28,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-alarm-evacuation-030","利用各種減光罩對光電式分離型探測器進行測試，以確認其火災動作試驗、不作動試驗、故障警報試驗並判定是否符合規定，下列方式何者錯誤？",30,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-alarm-evacuation-027","依各類場所消防安全設備設置標準第 112 條，有關火警自動警報設備之火警分區劃定規定，下列何者錯誤？",27,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-alarm-evacuation-031","依各類場所消防安全設備設置標準對於出口標示燈設置之相關規定，下列何者正確？",31,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-alarm-evacuation-026","依各類場所消防安全設備設置標準規定，裝置面高度 10 公尺者，不可選擇下列何種探測器設置？",26,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-alarm-evacuation-032","下列出口標示燈及避難方向指示燈之緊急電源描述何者正確？",32,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-029",113,"有關特別安全梯與緊急昇降機間排煙室兼用時，其排煙設備採機械排煙、自然進風方式，則排煙機之排煙量應在 X m3\u002Fsec 以上；直接面向戶外之進風口開口面積應在 Y m2 以上則 X、Y 各為多少？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-029",112,"某建築物總樓地板面積在 5 萬平方公尺以上其主要避難路徑的地方，該出口標示燈及避難方向指示燈之緊急電源容量應在 60 分鐘以上，下列場所何者不是主要避難路徑？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-029",111,"緩降機為顧及使用之安全，裝置時應考慮之位置下列何者為佳？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-alarm-evacuation-029",110,"有關瓦斯漏氣檢知器之設置，當瓦斯對空氣之比重小於 1 時，應設於距瓦斯燃燒器具水平距離 A 公尺以內；當瓦斯對空氣之比重大於 1 時，應設於距瓦斯燃燒器具水平距離 B 公尺以內，其中 A 及 B 分別為：",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-alarm-evacuation-029",109,"有關瓦斯漏氣火警自動警報設備檢知器外觀檢查選取之檢查數量，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",1785129964877]