[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-alarm-evacuation-022":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-警報與避難系統消防安全設備概要-022","fire-108-1-alarm-evacuation-022",108,1,22,"依照各類場所消防安全設備檢修及申報作業基準之規定，會結露之場所適用的探測器為下列何者？",{"A":16,"B":17,"C":18,"D":19},"差動式局限型探測器","定溫式局限型探測器","火焰式局限型探測器","偵煙式局限型探測器","B",null,[],false,"本題考點：會結露之場所該選哪一種探測器，關鍵在《各類場所消防安全設備設置標準》第 117 條所列「不得設置」的處所清單及其適應性表。\n【正解理由】依第 117 條第 1 項第 7 款，偵煙式或熱煙複合式局限型探測器不得設於會結露之場所；同條第 2 項第 1 款又把火焰式探測器一併排除於前項第七款所列之處所。再看同條的適應性表，差動式局限型（一種、二種）在「會結露之場所」欄並未標示適用，僅在排放廢氣會大量滯留、煙會大量流入兩欄標示適用；標示適用於結露場所的是差動式分布型。四個選項中，未被條文排除、且屬局限型而能適用於結露場所者，只有定溫式局限型，故選 B。\n【逐項排除】\n(A) 差動式局限型在第 117 條適應性表之「會結露之場所」欄未標示適用；其感熱室與接點易因水氣凝結而失效或誤動作。\n(B) 定溫式局限型以周圍溫度達標稱動作溫度而動作，構造上可採防水型，於結露環境仍能維持機能，為本題應選者。\n(C) 火焰式探測器依第 117 條第 2 項第 1 款，於前項第七款之會結露處所不得設置。\n(D) 偵煙式局限型依第 117 條第 1 項第 7 款明文不得設於會結露之場所，凝結水滴會被誤判為煙粒子而誤報。\n【記憶點】會結露：偵煙式、熱煙複合式、火焰式一律出局；差動式要用分布型，局限型就選定溫式（防水型）。","第 117 條第 1 項列出偵煙式或熱煙複合式局限型探測器不得設置的八種處所：塵埃、粉末或水蒸氣會大量滯留之場所；會散發腐蝕性氣體之場所；廚房及其他平時煙會滯留之場所；顯著高溫之場所；排放廢氣會大量滯留之場所；煙會大量流入之場所；會結露之場所；其他對探測器機能會造成障礙之場所。第 2 項再就火焰式探測器另立清單，包含前項第二款至第四款、第六款、第七款所列處所，加上水蒸氣會大量滯留之處所、用火設備火焰外露之處所等。第 3 項的適應性表則把這八種場所與各型探測器交叉比對，逐格標示是否適用——這張表是本科的高頻考點，建議直接把「哪一種探測器在哪一欄有標示」記成圖像。\n選型的物理邏輯可以這樣理解：偵煙式靠煙粒子遮蔽光線或改變離子電流，凝結的水滴、蒸氣、粉塵都會產生同樣的效果，所以凡是空氣中有「非煙的懸浮物」就先把偵煙式排除；差動式靠急遽溫升動作，局限型的感熱室體積小、易受潮氣與凝結水影響，分布型則以空氣管或熱電偶分散配置、耐候性較佳，因此結露場所允許用分布型而不用局限型；定溫式只認一個門檻溫度、構造單純又可做成防水型，是惡劣環境的萬用解。\n配套的還有兩條：第 115 條規定探測器之裝置位置——天花板上設有出風口時，除火焰式、差動式分布型及光電式分離型外，應距該出風口一點五公尺以上；牆上設有出風口時亦同，但該出風口距天花板在一公尺以上者不在此限；天花板設排氣口或回風口時，偵煙式探測器應裝置於其周圍一公尺範圍內；局限型探測器以裝置在探測區域中心附近為原則，且不得傾斜四十五度以上（火焰式除外）。第 120 條則給出差動式、補償式與定溫式局限型的有效探測範圍表，並在第 3 款要求具定溫式性能之探測器應裝設在平時之最高周圍溫度比其標稱動作溫度低攝氏二十度以上處，避免在高溫環境誤動作——這正是定溫式雖耐惡劣環境、卻不能裝在顯著高溫場所的原因。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-alarm-evacuation-021","依各類場所消防安全設備設置標準規定，下列危險物品場所何者不須設置火警自動警報設備？",21,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-alarm-evacuation-023","偵煙式局限型探測器裝設於防火構造建築物天花板高度 8 公尺之裝置面時，若樓地板面積為 500 平方公尺，且其天花板中間有一下垂 40 公分的樑隔開，試問至少須設置幾個偵煙式局限型 1 種探測器？",23,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-alarm-evacuation-020","依消防法令規定，觀光旅館、飯店、旅館、招待所（限有寢室客房者）等場所，採膠囊式經營時，須設置火警自動警報設備者，下列何者錯誤？",20,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-alarm-evacuation-024","某防火構造建築物，供三溫暖洗澡區使用，面積為 130 m2，天花板高度為 3.6 m，請問下列何者為適當的探測器？",24,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-alarm-evacuation-019","應設排煙設備場所之樑為裸露式者，交錯之樑形成之各防煙區劃皆應設置排煙口。但其樓地板面積每 500 平方公尺防煙區劃內，防煙壁及排煙口之設置，符合各類場所消防安全設備設置標準第 188 條第 1 項第 3 款規定，並符合下列何者，不在此限？〔A：大樑深度（cm）；B：中樑深度（cm）；X：大樑下加設之垂壁高度（cm），其值得為 0；A＋X：防煙壁下垂高度（cm）。〕",19,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-alarm-evacuation-025","依各類場所消防安全設備設置標準規定，火警自動警報設備之火警發信機（非定址式）與 P 型受信總機，其配線為何種配線？",25,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-022",113,"某建築物設有火警受信總機 50 回路，竣工時實施性能試驗，於進行受信總機同時動作試驗時，使用常用電源，應將任意 X 回路設定在火警動作狀態；使用預備電源，應將任意 Y 回路設定在火警動作狀態，判定受信總機、主音響裝置、地區音響裝置、附屬裝置等性能應無異常。則 X+Y=？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-022",112,"有關感熱型探測器定溫式（非再用型）性能檢查之選取檢查數量，依據火警自動警報設備檢修基準，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-022",111,"避難器具安裝完成實施性能試驗，針對支固器具進行荷重試驗，緩降機至少應載重 X kg 以上；救助袋應載重 Y kg 以上，試問 X、Y 分別為何？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-alarm-evacuation-022",110,"有一地下 3 層、地上 7 層之建築物，各層樓地板面積為 600 平方公尺，若地下 1 樓發生火警，則火警自動警報設備之鳴動樓層，下列何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-alarm-evacuation-022",109,"有關使用瓦斯之場所供各類場所消防安全設備設置標準第 12 條第 5 款第 1 目使用之地下層，其樓地板面積合計 X 平方公尺以上，且其中甲類場所樓地板面積合計 Y 平方公尺以上者，應設置瓦斯漏氣火警自動警報設備，下列何者與該設置標準之規定相同？",1785129964799]