[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-alarm-evacuation-011":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-警報與避難系統消防安全設備概要-011","fire-108-1-alarm-evacuation-011",108,1,11,"為提升火災發生時之通報效率，並避免延誤報案致生重大火災事故，各類場所消防安全設備設置標準於 107 年 10 月 17 日增列下列那一種設備種類？",{"A":16,"B":17,"C":18,"D":19},"一一九火警通報裝置設備","一一九火災通報裝置設備","一一九火警報知裝置設備","一一九火災報知裝置設備","B",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 9 條警報設備種類，於一百零七年十月十七日增列之第五款設備正式名稱，考的是條文用字的逐字精確度。\n【正解理由】第 9 條列警報設備種類為火警自動警報設備、手動報警設備、緊急廣播設備、瓦斯漏氣火警自動警報設備，以及第五款之「一一九火災通報裝置」。條文用字為「火災通報」，既非「火警通報」，亦非「報知裝置」，故選 B。該款係為提升火災發生時之通報效率、避免延誤報案致生重大火災事故而增列，列為警報設備之第五種。\n【逐項排除】\n(A) 「一一九火警通報裝置」將「火災」誤植為「火警」；本標準中火警一詞用於火警自動警報設備、火警發信機等，與本裝置之法定名稱不同，兩者所指涉之設備亦不相同。\n(B) 「一一九火災通報裝置」與第 9 條第五款文字完全相符，為本題應選者。\n(C) 「一一九火警報知裝置」同時錯用火警與報知二詞，報知在本標準中並非設備之正式名稱，屬日式用語之直譯。\n(D) 「一一九火災報知裝置」前段用字正確，末段誤為報知裝置，仍與條文名稱不符；四個選項僅一二字之差，須逐字核對。\n【記憶點】記住「火災通報」四字：通報的是火災，通報的對象是一一九。","一一九火災通報裝置的功能，是在場所端一經啟動即自動接通消防救災救護指揮中心並播放預錄訊息，同時可雙向通話，使不具通報能力或人力薄弱的場所不必依賴人員撥號報案。其設置對象由第 22-1 條界定：供第十二條第一款第六目所定醫院、療養院、榮譽國民之家、長期照顧服務機構、老人福利機構、護理機構、身心障礙福利機構等使用之場所，以及其他經中央主管機關公告之供公眾使用之場所。這些場所的共同特徵是使用人自力避難困難、夜間值班人力薄弱，一旦延誤報案，火災成長期的黃金時間隨即耗盡，這正是增列本裝置的背景。\n設置細節見第 145-1 條，共六款：應具手動及自動啟動功能；應設於值日室等經常有人之處所，但設有防災中心時應設於該中心；設置遠端啟動裝置時，應設有可與設置一一九火災通報裝置場所通話之設備；手動啟動裝置之操作開關距離樓地板面之高度，在零點八公尺以上一點五公尺以下；裝置附近應設置送、收話器，並與其他內線電話明確區分；應避免斜裝置，並採取有效防震措施。其中操作高度零點八至一點五公尺，與無線電通信輔助設備接頭之設置高度相同，是本標準對「站立操作」的一貫尺度。\n體系上，第 7 條把各類場所消防安全設備分為滅火設備、警報設備、避難逃生設備、消防搶救上之必要設備，以及其他經中央主管機關認定之消防安全設備五大類，警報設備即第 9 條所列五種；滅火設備則依第 8 條列滅火器與消防砂、室內消防栓設備、室外消防栓設備、自動撒水設備、水霧滅火設備、泡沫滅火設備、二氧化碳滅火設備、乾粉滅火設備、簡易自動滅火設備。命題者在本題型常設兩種陷阱：一是把手動報警設備與一一九火災通報裝置混為一談，前者按下發信機使建築物內警鈴與受信總機作動，作用對象是場所內的人；後者則把訊息送出建築物外，作用對象是消防機關。二是名稱的細微用字，本標準對火警、火災、通報、報知四詞的使用相當固定，作答時逐字比對即可分辨。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-alarm-evacuation-010","某一廣播區域面積為 150 平方公尺，設有揚聲器，請問距所設揚聲器 1 m 處所測得之音壓須達多少以上才符合規定？",10,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-alarm-evacuation-012","有關依各類場所消防安全設備設置標準規定設置之耐燃保護、耐熱保護措施，室內消防栓、室外消防栓、自動撒水、水霧、泡沫、乾粉、二氧化碳滅火設備、連結送水管設備等之配管，於實施施工、加壓試驗及配合建築物樓地板、樑、柱、牆施工須預埋消防管線時，消防專技人員何人應一併拍照建檔存證以供消防機關查核，消防機關並得視需要隨時派員前往查驗？",12,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-alarm-evacuation-009","緩降機固定架或支固器具使用錨定螺栓固定時，選用螺紋標稱為 M12×1.75 之螺栓，試問其螺栓埋入混凝土內不含灰漿部分之深度（mm）及轉矩值須為多少（kgf-cm）？",9,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-alarm-evacuation-013","有關避難器具之外觀試驗，下列何者不屬於外觀試驗？",13,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-alarm-evacuation-008","感熱式局限型探測器使用加熱試驗器對探測器加熱，依動作時間方法判斷，下列何者符合動作時間之規定？（標稱動作溫度與周圍溫度之差低於 50 度）",8,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-alarm-evacuation-014","緊急照明設備性能試驗之水平面照度測試，切換為緊急電源狀態亮燈，經過 A 分鐘後，使用 B 測試，確認緊急照明燈之照度有無達到法規所規定之值。請問前述 A、B 為何？",14,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-011",113,"某一場所設有一 A 級出口標示燈，其縱向尺度為 0.8 公尺，且未顯示避難方向符號者，請問其步行距離應為多少公尺？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-011",112,"依據火警探測器認可基準之構造及材質規定，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-011",111,"依各類場所消防安全設備設置標準規定，下列場所何者未強制要求設置 119 火災通報裝置？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-alarm-evacuation-011",110,"特別安全梯間與緊急昇降機間兼用之排煙室，如設置排煙管道及進風管道，下列何者在綜合試驗中應判定合格？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-alarm-evacuation-011",109,"避難器具設置數量需衡酌場所之收容人數，依各類場所消防安全設備設置標準規定，百貨商場供飲食或休息用場所之收容人數計算，應以該部分樓地板面積除多少？",1785129964699]