[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-water-chemical-027":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-水與化學系統消防安全設備概要-027","fire-107-1-water-chemical-027",107,1,27,"有關二氧化碳滅火設備放射時間之敘述，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"全區放射方式，總機室 1 分鐘全部放射完畢","全區放射方式，其他場所 0.5 分鐘全部放射完畢","局部放射方式，0.5 分鐘全部放射完畢","局部放射方式，1 分鐘全部放射完畢","C",null,[],false,"本題考點：二氧化碳滅火設備依放射方式(全區、局部)所定的滅火藥劑放射時間。\n【正解理由】依《各類場所消防安全設備設置標準》二氧化碳滅火設備噴頭一節關於滅火藥劑放射時間之規定，局部放射方式所核算之滅火藥劑量應於三十秒內全部放射完畢，三十秒即 0.5 分鐘；全區放射方式則依場所分別規定，電信機械室、總機室等為 3.5 分鐘，其他場所為 1 分鐘。選項 C 所述局部放射 0.5 分鐘與規定相符，故選 C。\n【逐項排除】\n(A) 總機室屬全區放射中放射時間較長的一類，規定為 3.5 分鐘，寫成 1 分鐘與規定不符。\n(B) 全區放射方式的其他場所為 1 分鐘,0.5 分鐘是局部放射的時間，兩者被對調。\n(C) 局部放射方式須於三十秒(0.5 分鐘)內全部放射完畢，為正解。\n(D) 局部放射並非 1 分鐘;1 分鐘是全區放射其他場所的規定，同屬時間張冠李戴。\n【記憶點】二氧化碳放射時間由短到長：局部半分鐘、全區其他場所一分鐘、總機室三點五分鐘。","放射時間之所以因放射方式而異，關鍵在滅火機制。全區放射是把整個防護區劃充填到設計濃度(二氧化碳一般以體積濃度三成餘為目標)並維持一段時間，靠稀釋氧氣窒息滅火；放射太快，冷卻收縮與開口洩漏會讓濃度來不及均勻分布，放射太慢又會讓火勢在達到濃度前擴大，故條文以場所性質分訂時間。電信機械室、總機室這類場所以電氣設備陰燃為主，火點常藏在機櫃與電纜束內部，需要較長時間讓藥劑滲入並維持濃度，時間因而訂得最長；一般場所以表面火災為主，時間短即可。局部放射則不封閉區劃，而是直接對防護對象表面噴覆，藥劑一旦停止供應立刻被氣流帶走，必須在極短時間內以高濃度覆蓋火面，所以規定三十秒內全部放射完畢。\n同樣是三十秒的還有乾粉：第 100 條規定全區及局部放射方式所核算之滅火藥劑量須於三十秒內全部放射完畢，且乾粉噴頭之放射壓力在每平方公分一公斤以上或 0.1MPa 以上。乾粉以抑制連鎖反應為主，講究瞬間高濃度覆蓋，與二氧化碳局部放射的邏輯相同，可以合併記憶——遇到「三十秒」先想局部放射與乾粉。\n二氧化碳的放射方式共有三類：全區放射、局部放射、移動放射。全區放射適用於以不燃材料建造之牆、柱、樓地板或天花板等區劃間隔且開口部設有自動關閉裝置的區域；局部放射視防護對象之形狀、構造、數量及性質配置噴頭；移動放射則以皮管拉至防護對象處使用。命題常見手法有二：一是把全區與局部的時間對調，二是把總機室的較長時間換成一般場所的一分鐘。作答時先辨識放射方式，再辨識場所性質，兩層判斷缺一不可。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-water-chemical-026","室內消防栓設備之消防立管管系竣工時，應做加壓試驗，試驗壓力不得小於加壓送水裝置全閉揚程 A 倍以上之水壓。試驗壓力以繼續維持 B 小時無漏水現象為合格，A、B 分別為：",26,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-water-chemical-028","有關滅火器性能檢查頻率之規定，下列敘述何者正確？",28,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-water-chemical-025","泡沫滅火設備進行綜合檢查時，有關泡沫滅火藥劑 25%還原時間標準值敘述，下列何者正確？",25,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-water-chemical-029","全區放射二氧化碳滅火設備進行綜合檢查時，如為高壓式儲存系統，在放射試驗時需放射多少藥劑量？",29,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-water-chemical-024","竣工查驗時，於屋頂使用口徑 16 mm 瞄子實施第一種室內消防栓綜合檢查，測得放水壓力為 4 kgf\u002Fcm2，所計算之每分鐘放水量約為：",24,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-water-chemical-030","實施二氧化碳滅火設備檢修，於進行性能檢查時，皮管連接部應無鬆動，皮管損傷、老化等情形，且皮管長度應在幾公尺以上？",30,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-027",113,"公共危險物品等場所設置之室內消防栓設備，應符合下列何者規定？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-water-chemical-027",112,"有關自動撒水設備設置流水檢知裝置規定，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-water-chemical-027",111,"自動撒水採用密閉乾式或預動式自動撒水設備，撒水頭動作後，流水檢知裝置應在幾分鐘內，使撒水頭放水？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-water-chemical-027",110,"二氧化碳滅火設備之全區放射或局部放射方式防護區域，對放射之滅火藥劑之排放規定，下列何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-water-chemical-027",109,"中央消防主管機關認定儲存大量可燃物之場所天花板高度超過 6 公尺，或其他場所天花板高度超過 10 公尺者，應採用何種撒水頭？",1785129973254]