[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-water-chemical-023":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-水與化學系統消防安全設備概要-023","fire-107-1-water-chemical-023",107,1,23,"有關室內消防栓綜合檢查放水量及放水壓力之敘述，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"第一種消防栓放水量應在 120 l\u002Fmin 以上","第二種消防栓放水量應在 60 l\u002Fmin 以上","第一種消防栓放水壓力應在 1.3 kgf\u002Fcm2 以上 7 kgf\u002Fcm2 以下","第二種消防栓放水壓力應在 2.3 kgf\u002Fcm2 以上 7 kgf\u002Fcm2 以下","B",null,[],false,"本題考點：室內消防栓設備綜合檢查時，第一種與第二種消防栓的放水壓力與放水量判定值。\n【正解理由】依《消防安全設備檢修及申報作業基準》室內消防栓設備綜合檢查之判定方法，第一種消防栓放水壓力應在 1.7 kgf\u002Fcm² 以上 7 kgf\u002Fcm² 以下、放水量在 130 L\u002Fmin 以上；第二種消防栓放水壓力應在 2.5 kgf\u002Fcm² 以上 7 kgf\u002Fcm² 以下、放水量在 60 L\u002Fmin 以上(本場考試日為 107 年 6 月 3 日，以當時規定為準)。選項 B 所稱第二種放水量 60 L\u002Fmin 以上與判定值相符，故選 B。\n【逐項排除】\n(A) 第一種消防栓放水量判定值為 130 L\u002Fmin 以上,120 L\u002Fmin 低於門檻。\n(B) 第二種消防栓當時之放水量判定值即為 60 L\u002Fmin 以上，為正解。\n(C) 第一種放水壓力下限為 1.7 kgf\u002Fcm²,寫成 1.3 kgf\u002Fcm² 屬數值誤植；上限 7 kgf\u002Fcm² 部分則正確。\n(D) 第二種放水壓力下限為 2.5 kgf\u002Fcm²,2.3 kgf\u002Fcm² 不足；第二種瞄子口徑小、放水量低，所需壓力反而比第一種高，這正是本題的辨識點。\n【記憶點】第一種記「一點七、一三○」,第二種記「二點五、六○」,兩者放水壓力上限同為 7 kgf\u002Fcm²。","第一種與第二種室內消防栓的差別，源自「幾個人能操作」。第一種配置口徑三十八毫米或五十毫米之消防栓、長十五公尺並附快式接頭之水帶二條、水帶架一組及口徑十三毫米以上之直線水霧兩用瞄子，水帶為摺疊式，展開與操作通常需二人，換來的是較大的放水量；第二種配置口徑二十五毫米消防栓連同管盤長三十公尺之皮管或消防用保形水帶及直線水霧兩用瞄子，瞄子設有容易開關之裝置，保形水帶不必全部展開即可出水，一人即可操作，但流量較小。流量小、口徑小，要把水送到同樣的射程，末端壓力就得更高，所以第二種的放水壓力下限反而高於第一種——這個「量小壓大」的反差是本題的核心。\n綜合檢查是在放水壓力最不利的部分(通常是最高樓層或最遠處)實測，以皮托管量測瞄子前端動壓，再對照判定值。放水壓力同時設有上限，是因為壓力過高會使瞄子反作用力增大而難以持握，故放水壓力超過每平方公分七公斤時，應採取有效之減壓措施；室外消防栓亦有相同體例，例如第 210 條即規定室外消防栓瞄子放水壓力超過每平方公分七公斤或 0.7MPa 時，應採取有效之減壓措施。\n單位換算是本科通則:1 kgf\u002Fcm² 約等於 0.098MPa,也約等於 10 公尺水頭，所以 1.7 kgf\u002Fcm² 約 0.17MPa、約 17 公尺水頭,2.5 kgf\u002Fcm² 約 0.25MPa、約 25 公尺水頭。看到條文常數 17m 或 25m,就能立刻回推末端所需壓力。\n※ 第二種室內消防栓之放水量法定值於 107 年 10 月修正過，本題考試日在該次修正之前，故仍以當時的 60 L\u002Fmin 判定；作答歷屆題時，務必先確認該場考試日期落在哪一版條文之下，再套數值。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-water-chemical-022","可燃性高壓氣體場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽設置滅火器，其設置規定，下列敘述何者正確？",22,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-water-chemical-024","竣工查驗時，於屋頂使用口徑 16 mm 瞄子實施第一種室內消防栓綜合檢查，測得放水壓力為 4 kgf\u002Fcm2，所計算之每分鐘放水量約為：",24,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-water-chemical-021","有關乾粉滅火設備配管設置規定，下列敘述何者正確？",21,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-water-chemical-025","泡沫滅火設備進行綜合檢查時，有關泡沫滅火藥劑 25%還原時間標準值敘述，下列何者正確？",25,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-water-chemical-020","室內消防栓之水源採重力水箱設置，下列何種裝置不屬於該構造應有之裝置？",20,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-water-chemical-026","室內消防栓設備之消防立管管系竣工時，應做加壓試驗，試驗壓力不得小於加壓送水裝置全閉揚程 A 倍以上之水壓。試驗壓力以繼續維持 B 小時無漏水現象為合格，A、B 分別為：",26,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-023",113,"有關停車空間泡沫瞄子綜合試驗，下列敘述何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-water-chemical-023",112,"依各類場所消防安全設備設置標準規定，下列何種場所不需設置室內消防栓設備？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-water-chemical-023",111,"簡易自動滅火設備進行性能檢查時，蓄壓式滅火藥劑儲存容器滅火藥劑量應與標示差異不超過多少？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-water-chemical-023",110,"下列場所何者可選擇第二種室內消防栓選擇設置之？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-water-chemical-023",109,"下列有關室內消防栓箱之敘述，何者正確？",1785129973230]