[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-fire-law-032":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-消防法規概要-032","fire-107-1-fire-law-032",107,1,32,"依各類場所消防安全設備設置標準之規定，有關無線電通信輔助設備，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"無線電通信輔助設備使用洩波同軸電纜，該電纜適合傳送或輻射 150 百萬赫（MHz）或中央主管機關指定之周波數","洩波同軸電纜之標稱阻抗為 50 歐姆","洩波同軸電纜經耐熱處理","設增輻器時，該增輻器之緊急電源，應使用蓄電池設備，其能量能使其有效動作 30 分鐘以上。","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 183 條無線電通信輔助設備之洩波同軸電纜規格與增輻器緊急電源要求，題目問「錯誤」者。\n【正解理由】依《各類場所消防安全設備設置標準》第 183 條，無線電通信輔助設備使用洩波同軸電纜者，該電纜應經耐燃處理，而非僅耐熱處理。C 將法定的「耐燃」寫成「耐熱」,防火性能等級被降階，與條文不符，故選 C。\n【逐項排除】\n(A) 正確。第 183 條明定洩波同軸電纜應適合傳送或輻射一百五十百萬赫(MHz)或中央主管機關指定之周波數，與消防救災無線電使用頻段相符。\n(B) 正確。洩波同軸電纜之標稱阻抗為五十歐姆，為條文明定值，亦是射頻傳輸線的通用阻抗規格。\n(C) 錯誤。條文要求的是耐燃處理；耐燃與耐熱在消防法規中是兩種不同等級的性能要求，耐燃的火害耐受條件較嚴，以「耐熱」替代即不符規定，為本題答案。\n(D) 正確。設增輻器時，其緊急電源應使用蓄電池設備，且能量能使其有效動作三十分鐘以上，符合條文。\n【記憶點】洩波同軸電纜三組數字與一個等級:150 MHz、50 歐姆、增輻器三十分鐘，電纜一律「耐燃」不是耐熱。","無線電通信輔助設備的存在理由，是地下建築物與地下層的鋼筋混凝土結構對無線電波衰減極大，消防人員進入後與指揮站失聯，將直接危及搶救安全與人員撤離決策。洩波同軸電纜(leaky coaxial cable)的原理是在外導體上開設週期性的細縫，讓一部分電磁能量沿路徑洩漏出來，使整條電纜等效於一支沿走道延伸的分散式天線，因而能在無視線的地下空間維持通信。五十歐姆的標稱阻抗並非法規任意指定，而是射頻傳輸線在功率承載能力與損耗之間取得平衡的業界標準值，阻抗不匹配會造成駐波與反射損失，削弱通信距離。\n\n一百五十百萬赫的頻段設定，對應消防救災實務使用的特高頻無線電；條文同時保留「中央主管機關指定之周波數」的彈性，以因應通信頻率政策調整，這種「明定值＋授權指定」的立法方式在設置標準中相當常見，命題時常拿掉後半段當作錯誤選項。\n\n耐燃與耐熱的區辨是本題核心，也是整部設置標準的通用觀念：配線的防火性能分為耐燃配線與耐熱配線兩級，耐燃配線用於必須在火災持續期間仍維持功能的線路(如緊急電源主幹線、無線電通信輔助設備的洩波同軸電纜),耐熱配線則用於受熱環境下短時間仍需動作的線路(如探測器回路、表示燈線路)。凡是題目把兩者對調，一律是錯誤選項，這個判別法可以套用到火警自動警報設備、緊急廣播設備等多題。\n\n配套要件補充：無線電通信輔助設備的無線電接頭應設於地面層出入口、消防人員便於取用處與防災中心，並設保護箱標明「消防隊專用無線電接頭」字樣，同屬第 183 條體系內的高頻考點。\n\n答題節奏建議：凡見到洩波同軸電纜，先默寫「150 MHz／50 歐姆／耐燃／增輻器蓄電池 30 分鐘」四項，再與選項逐一核對，四項中被動到任何一項的即為錯誤選項，判斷速度可壓在半分鐘內完成。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-fire-law-031","依各類場所消防安全設備設置標準之規定，有關緊急電源插座，下列敘述何者正確？",31,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-fire-law-033","依各類場所消防安全設備設置標準之規定，防災中心樓地板面積應在多少平方公尺以上？",33,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-fire-law-030","依各類場所消防安全設備設置標準之規定，下列何者應設置連結送水管？",30,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-fire-law-034","依各類場所消防安全設備設置標準之規定，下列何者非屬甲類場所？",34,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-fire-law-029","依各類場所消防安全設備設置標準之規定，下列何者應設置室外消防栓設備？",29,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-fire-law-035","依各類場所消防安全設備檢修及申報作業基準之規定，有關瓦斯漏氣火警自動警報設備性能檢查，下列何者錯誤？",35,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-032",114,"依可燃性高壓氣體場所標示板規格及設置要點規定，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-032",113,"依建築技術規則建築設計施工編規定，有關耐燃合板、耐燃纖維板、耐燃塑膠板及石膏板等耐燃材料，係指耐燃幾級之材料？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-032",112,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準之規定，下列敘述何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-032",111,"供某住宿式長期照顧機構使用之五層樓建築物，各樓層若符合下列何者之規定，得免設避難器具？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-032",110,"裝置避難器具之固定部（係指裝設避難器具之樑、柱、樓板等堅固構造或經補強之部分）直接裝置在建築物主要構造部之施工方法，若以金屬膨脹錨定螺栓之施工方法，金屬膨脹錨定螺栓間之間隔，應為埋入深度之幾倍以上？",1785129970635]