[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-fire-law-031":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-消防法規概要-031","fire-107-1-fire-law-031",107,1,31,"依各類場所消防安全設備設置標準之規定，有關緊急電源插座，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"緊急電源插座之電流供應容量為交流單相 110 伏特（或 120 伏特）10 安培，其容量約為一瓩以上","緊急電源插座為接地型，裝設高度距離樓地板 0.8 公尺以上 1.5 公尺以下，且裝設二個於符合規定之崁裝式保護箱","緊急電源插座在保護箱上方設紅色表示燈","應從主配電盤設專用回路，專用回路應設漏電斷路器","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 235 條緊急電源插座之構造、裝設高度與回路規定。\n【正解理由】依《各類場所消防安全設備設置標準》第 235 條，緊急電源插座應設於保護箱內，並在保護箱上方設紅色表示燈，供消防人員於火場中辨識插座位置。C 的敘述與該條文字相符，故選 C。\n【逐項排除】\n(A) 錯在電流與容量數值。依第 235 條，緊急電源插座之電流供應容量為交流單相一百十伏特(或一百二十伏特)十五安培以上，其容量約為一點五瓩以上；選項寫成十安培、約一瓩，兩個數字都被下修。\n(B) 錯在裝設高度。條文規定裝設高度距離樓地板一公尺以上一點五公尺以下，並裝設二個於符合規定之崁裝式保護箱；選項下限誤植為零點八公尺。\n(C) 正確。保護箱上方設紅色表示燈是條文明文，紅色亦與消防設備標示的一致性要求相符，為正解。\n(D) 錯在漏電斷路器。條文要求應從主配電盤設專用回路，各層任兩處插座應接於不同回路，且應設專用開關並標明字樣，但明定不得設漏電斷路器；因火場中水與電同時存在，漏電斷路器一旦跳脫會使消防人員的電動器材斷電。\n【記憶點】緊急電源插座記「110V／15A／1.5 瓩、高度 1～1.5 公尺、紅色表示燈、專用回路不設漏電斷路器」。","緊急電源插座屬於消防搶救上之必要設備，設置目的是讓消防人員在火場內直接取用電源驅動照明、破壞器材、排煙機與救助器具，而不必從樓下拉長距離延長線。理解這個目的，條文的每個要件就都有解釋力：紅色表示燈是為了在濃煙與斷電環境下辨識；裝設高度一公尺以上一點五公尺以下，是配合著裝空氣呼吸器的消防人員站姿操作的手部高度；每處裝設二個插座，是因為單一器材常需搭配照明同時使用；各層任兩處插座接於不同回路，則是避免單一回路故障造成整層無電可用的單點失效。\n\n最需要強記的是「不得設漏電斷路器」這個反直覺規定。一般用電安全思維會認為潮濕環境更該裝漏電保護，但火場中水霧與積水必然存在，漏電斷路器極易誤動作，若在破壞或搜索途中突然斷電，對人員的危害大於漏電本身，因此法規選擇以專用回路與專用開關作為替代性的安全設計。命題者非常喜歡把這條反過來寫成「應設漏電斷路器」當作錯誤選項。\n\n數值換算面向：交流單相 110 伏特、15 安培，理論視在功率為 110 V × 15 A ＝ 1650 VA,約 1.65 kVA,條文取「一點五瓩以上」即由此而來，這也解釋了為何選項 A 的「十安培約一瓩」在數學上勉強自洽卻與法定值不符——記住推導過程比死背數字更不易被干擾選項動搖。\n\n易混淆對照：緊急電源插座與無線電通信輔助設備同屬第五章消防搶救上之必要設備，兩者都有「保護箱」「紅色標示」的要件，但一個管電、一個管通信，增輻器緊急電源三十分鐘的規定屬於後者，不可張冠李戴。\n\n最後補一個答題節奏：緊急電源插座題型幾乎固定在「電壓電流容量、裝設高度、保護箱與表示燈、回路配置」四個面向出四個選項，拿到題目先把法定四組數值寫在草稿邊，再逐項核對，可在三十秒內完成判斷，不必逐字回想條文全文。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-fire-law-030","依各類場所消防安全設備設置標準之規定，下列何者應設置連結送水管？",30,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-fire-law-032","依各類場所消防安全設備設置標準之規定，有關無線電通信輔助設備，下列敘述何者錯誤？",32,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-fire-law-029","依各類場所消防安全設備設置標準之規定，下列何者應設置室外消防栓設備？",29,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-fire-law-033","依各類場所消防安全設備設置標準之規定，防災中心樓地板面積應在多少平方公尺以上？",33,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-fire-law-028","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，液化石油氣販賣場所儲放液化石油氣，總儲氣量不得超過 X 公斤，超過部分得設容器保管室儲放之，但總儲氣量以 Y 公斤為限。X、Y 分別為多少？",28,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-fire-law-034","依各類場所消防安全設備設置標準之規定，下列何者非屬甲類場所？",34,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-031",114,"依消防法相關規定，下列敘述何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-031",113,"依建築技術規則建築設計施工編規定，所謂「無窗戶居室」係指有效採光面積未達該居室樓地板面積多少者？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-031",112,"依消防安全設備及必要檢修項目檢修基準之規定，某一場所 2.5 英吋室外消防栓之瞄子口徑 19 mm，現場測得瞄子壓力為 4（kgf\u002Fcm2），其放水量計算式 Q=0.653D2 P ，試問室外消防栓瞄子放水量 Q 為多少（l\u002Fmin）？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-031",111,"依消防安全設備及必要檢修項目檢修基準規定，使用加熱試驗器分別對差動式局限型 1 種探測器及離子式局限型光電式局限型 2 種探測器加熱，確認其應動作之時間分別是 A 秒內及 B 秒內，A+B 為多少？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-031",110,"有關標示設備之規定，下列敘述何者正確？",1785129970632]