[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-fire-law-027":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-消防法規概要-027","fire-107-1-fire-law-027",107,1,27,"依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，製造、儲存或處理六類物品達管制量多少倍以上之場所，應由管理權人選任管理或監督層次以上之幹部為保安監督人，擬訂消防防災計畫，報請當地消防機關核定，並依該計畫執行六類物品保安監督相關業務？",{"A":16,"B":17,"C":18,"D":19},"20","30","40","50","B",null,[],false,"本題考點：《公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法》第 47 條所定保安監督人之選任門檻倍數。\n【正解理由】依《公共危險物品設置標準》第 47 條，製造、儲存或處理六類物品達管制量三十倍以上之場所，應由管理權人選任管理或監督層次以上之幹部為保安監督人，擬訂消防防災計畫，報請當地消防機關核定，並依該計畫執行六類物品保安監督相關業務；同條並要求保安監督人須經直轄市、縣(市)消防機關講習訓練合格才能執行職務。條文明定的倍數只有「三十倍」一個，選項中對應者為三十，故選 B。\n【逐項排除】\n(A) 二十倍在本辦法中並非保安監督人的門檻，它常被誤記是因為考生把公共危險物品其他管理規定的倍數混進來，依第 47 條並無二十倍之規定。\n(B) 三十倍與第 47 條文字完全一致，是保安監督人選任、消防防災計畫報請核定的唯一啟動門檻，故為正解。\n(C) 四十倍在本辦法全文找不到對應規定，屬命題者刻意安排的等差干擾值，不能作為選任依據。\n(D) 五十倍同樣無條文可引；若門檻拉高到五十倍，大量中型製造與儲存場所將免除保安監督義務，與本辦法防止公共危險物品災害擴大的立法目的相違。\n【記憶點】六類物品達管制量「三十倍」,就要選保安監督人並把消防防災計畫報消防機關核定。","保安監督人制度的源頭是《消防法》第 15 條：公共危險物品及可燃性高壓氣體之製造、儲存、處理場所，其安全管理事項授權中央主管機關訂定辦法;《公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法》即為該授權子法，第 47 條把「達管制量三十倍」訂為需要專責管理人力的分水嶺，理由是倍數愈高，一旦洩漏或起火，火載量與延燒範圍呈非線性放大，已非一般從業人員的日常巡檢所能控管，必須有管理或監督層次以上的幹部負責制度面。\n\n此處要分清三組容易互相污染的數值。第一組是「管制量」本身，它是各類六類物品(第一類氧化性固體至第六類氧化性液體)個別訂定的基準量，倍數＝實際數量÷管制量，多品項時採各品項倍數相加。第二組是「達管制量以上」即受本辦法規範、須申請完工檢查；第三組才是本題的「三十倍以上」須設保安監督人。考題最愛把這三層混在同一題選項裡，答題時先問自己「這句話管的是納管、檢查，還是人員?」。\n\n保安監督人的法定作為是「擬訂消防防災計畫→報請當地消防機關核定→依計畫執行」,三個動作缺一不可，計畫內容涵蓋自衛消防編組、防災設備維護、災害搶救初期應變與教育訓練。此外同辦法要求保安監督人接受講習訓練合格，且訓練時數與複訓期程另有規定，常以「幾年一次複訓」的形式出題。\n\n延伸考點：同一場所若既達三十倍又屬應設消防安全設備之場所，保安監督人的防災計畫與《消防法》第 13 條的消防防護計畫是兩份不同文件，分屬不同條文義務，不能互相取代——這是申論題常見的辨析點。\n\n最後提醒條號記憶法：本辦法的人員義務集中在第 47 條前後，把「三十倍→保安監督人→防災計畫→報核→講習訓練合格」串成一條動線背誦，遇到倍數型選項時就不會被二十、四十、五十這類等差干擾值帶走。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-fire-law-026","公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法所稱高閃火點物品，指閃火點在攝氏 X 度以上之第 Y 類公共危險物品，X、Y 分別為多少？",26,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-fire-law-028","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，液化石油氣販賣場所儲放液化石油氣，總儲氣量不得超過 X 公斤，超過部分得設容器保管室儲放之，但總儲氣量以 Y 公斤為限。X、Y 分別為多少？",28,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-fire-law-025","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，室外儲槽場所係指在建築物外地面上設置容量超過多少公升且不可移動之儲槽儲存六類物品之場所？",25,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-fire-law-029","依各類場所消防安全設備設置標準之規定，下列何者應設置室外消防栓設備？",29,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-fire-law-024","消防法所稱消防防護計畫應包括之事項，下列何者正確？",24,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-fire-law-030","依各類場所消防安全設備設置標準之規定，下列何者應設置連結送水管？",30,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-027",114,"依各類場所消防安全設備設置標準，針對滅火設備水源容量之規定，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-027",113,"依消防設備人員法規定，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-027",112,"依各類場所消防安全設備設置標準之規定，建築物總樓地板面積在多少平方公尺以上應設置防災監控系統綜合操作裝置？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-027",111,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，儲存第五類公共危險物品分級屬 A 型，其儲存量達管制量 5 倍以上未達 10 倍者且周圍設有圍牆之室內儲存場所，其應保留空地寬度應為多少公尺以上？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-027",110,"依各類場所消防安全設備設置標準規定，自動撒水設備得依實際情況需要選擇適當型式設置。但下列何種場所應設開放式？",1785129970602]