[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-fire-law-025":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-消防法規概要-025","fire-107-1-fire-law-025",107,1,25,"依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，室外儲槽場所係指在建築物外地面上設置容量超過多少公升且不可移動之儲槽儲存六類物品之場所？",{"A":16,"B":17,"C":18,"D":19},"200","300","600","1000","C",null,[],false,"本題考點：室外儲槽場所的定義門檻，關鍵在「建築物外地面上」「容量超過六百公升」「不可移動」三要件。\n【正解理由】依《公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法》第 4 條有關儲存場所之定義，室外儲槽場所指在建築物外地面上設置容量超過六百公升且不可移動之儲槽儲存六類物品之場所。故選 C。\n【逐項排除】\n(A) 二百公升非本定義之門檻值，容量門檻若訂得如此低，將使大量小型固定容器誤入儲槽場所管理體系，承擔防液堤與保安距離等不成比例之要求。\n(B) 三百公升同屬干擾值，條文所定門檻為六百公升，並非三百。\n(C) 正確，六百公升為儲槽場所與一般儲存場所的分界，超過者始適用儲槽場所之防液堤、保安距離等規定。\n(D) 一千公升為常見誤記值，若以此為門檻，容量六百公升至一千公升之不可移動儲槽將脫離儲槽場所之管制，與條文明定之六百公升不符。\n【記憶點】儲槽場所看「六百公升、不可移動、地面上」，六百是分水嶺。","六類物品場所的分類體系是公共危險物品法規的骨架，先分「製造場所、儲存場所、處理場所」三大類，儲存場所再依位置與容器型態細分為室內儲存場所、室外儲存場所、室內儲槽場所、室外儲槽場所、地下儲槽場所、可攜式儲槽場所等。判別室外儲槽場所的三要件缺一不可：位置須在建築物外的地面上（若埋設於地面下即為地下儲槽場所，若設於建築物內則為室內儲槽場所）、容量須超過六百公升（未超過者以容器儲存論，歸入室外儲存場所或室內儲存場所）、且須不可移動（可移動者屬可攜式儲槽或運送車輛之管制範圍）。\n六百公升這個門檻的意義在於管制強度的躍升：一旦認定為儲槽場所，隨之而來的是保安距離、防火空地、防液堤容量（單槽時為最大槽容量之百分之一百十以上，多槽時為最大槽容量之百分之一百十以上）、通氣管、液面計、注入口與幫浦設備等一整套硬體要求，還有第四類物品達顯著滅火困難程度時應設之固定式泡沫滅火設備與冷卻撒水設備。若門檻過高，中型儲槽將逃逸出管制；過低則使一般作業用小型容器承擔不成比例的成本，故立法上取六百公升作為平衡點。\n配套的管制數量概念亦須併記：六類物品之管制量依類別各異（如第四類第一石油類非水溶性為四百公升、第二石油類非水溶性為一千公升），達管制量以上者始須依本辦法申請設置許可並受檢查，未達管制量者依直轄市、縣（市）政府自治法規管理。因此實務判斷順序是：先算是否達管制量，再定場所類別，最後套用該類別的技術規範。\n※ 條號請以現行法規為準，六百公升之門檻值歷年未變。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-fire-law-024","消防法所稱消防防護計畫應包括之事項，下列何者正確？",24,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-fire-law-026","公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法所稱高閃火點物品，指閃火點在攝氏 X 度以上之第 Y 類公共危險物品，X、Y 分別為多少？",26,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-fire-law-023","依消防法施行細則之規定，防火管理人應為管理或監督層次人員，並經中央消防機關認可之訓練機構或直轄市、縣（市）消防機關講習訓練合格領有證書始得充任。其講習訓練時數，初訓不得少於 X 小時；複訓不得少於 Y 小時，X、Y 分別為多少？",23,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-fire-law-027","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，製造、儲存或處理六類物品達管制量多少倍以上之場所，應由管理權人選任管理或監督層次以上之幹部為保安監督人，擬訂消防防災計畫，報請當地消防機關核定，並依該計畫執行六類物品保安監督相關業務？",27,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-fire-law-022","下列場所，何者不屬於消防法施行細則所定一定規模以上供公眾使用建築物？",22,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-fire-law-028","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，液化石油氣販賣場所儲放液化石油氣，總儲氣量不得超過 X 公斤，超過部分得設容器保管室儲放之，但總儲氣量以 Y 公斤為限。X、Y 分別為多少？",28,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-025",114,"依消防設備人員法規定，有關消防設備人員的業務及責任，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-025",113,"依消防設備人員法規定，消防設備人員執業執照有效期間為幾年？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-025",112,"依各類場所消防安全設備設置標準之規定，應設置火警自動警報設備之場所及設備裝置，下列敘述何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-025",111,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關六類公共危險物品之販賣場所及其位置、構造及設備等規定，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-025",110,"某場所室內高度為 16 公尺，依各類場所消防安全設備設置標準規定，下列何者為可選擇之探測器種類？①定溫式特種 ②差動式分布型 ③光電式局限型一種 ④火焰式",1785129970592]