[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-fire-law-024":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-消防法規概要-024","fire-107-1-fire-law-024",107,1,24,"消防法所稱消防防護計畫應包括之事項，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"自衛消防編組：員工在 10 人以上者，至少編組滅火班、通報班及救護班；員工在 50 人以上者，應增編安全防護班及避難引導班","防火避難設施之自行檢查：每半年至少檢查一次，檢查結果遇有缺失，應報告管理權人立即改善","滅火、通報及避難訓練之實施：每半年至少應舉辦一次，每次不得少於 4 小時，並應事先通報當地消防機關","場所之平面圖、立體圖及逃生避難圖","C",null,[],false,"本題考點：《消防法施行細則》第 15 條消防防護計畫應包括事項的各項數值與內容，逐項比對何者敘述完全正確。\n【正解理由】依《消防法施行細則》第 15 條，滅火、通報及避難訓練之實施，每半年至少應舉辦一次，每次不得少於四小時，並應事先通報當地消防機關。選項 C 之頻率、時數與通報義務三要素均與條文一致，故選 C。\n【逐項排除】\n(A) 錯誤，自衛消防編組於員工十人以上者，至少編組滅火班、通報班及避難引導班；員工五十人以上者始增編安全防護班及救護班。本項將救護班與避難引導班的層級對調。\n(B) 錯誤，防火避難設施之自行檢查為每月至少檢查一次，而非每半年一次；每半年是訓練的頻率，兩者被刻意互換。\n(C) 正確，每半年一次、每次至少四小時、事先通報消防機關，三項要件齊備。\n(D) 錯誤，條文所定為場所之位置圖、逃生避難圖及平面配置圖，並無「立體圖」之要求，屬憑空增列的項目。\n【記憶點】自行檢查每月、訓練每半年四小時；圖說是位置圖、逃生避難圖與平面配置圖，沒有立體圖。","消防防護計畫是把《消防法》第 13 條的抽象義務落實為可執行文件，條文以列舉方式規定應包括事項，包括自衛消防編組、防火避難設施之自行檢查、消防安全設備之維護管理、火災及其他災害發生時之滅火行動、通報聯絡及避難引導、避難逃生路線圖、防災應變之教育訓練、用火用電之監督管理、消防安全設備之操作演練、場所之位置圖與逃生避難圖及平面配置圖等。測驗題幾乎都從其中的數字下手，考生宜建立一張數值表：自行檢查每月一次、訓練每半年一次且每次四小時以上、編組門檻十人與五十人、複合用途場所另有共同防護計畫。\n自衛消防編組的兩段式門檻有其邏輯：十人以上時先確保三項最基本機能——把火壓住（滅火班）、把消息傳出去（通報班）、把人帶出來（避難引導班）；規模擴大到五十人以上，火場範圍與滯留人數增加，才需要安全防護班負責防火區劃關閉、電氣瓦斯遮斷等延燒抑制工作，以及救護班處理傷患。理解這個由「基本三班」到「加值兩班」的設計，比死背順序更不易被選項對調騙到。\n訓練的「事先通報當地消防機關」也常被漏看，其目的一方面便於消防機關派員指導與查核，另一方面避免大量人員疏散演練被誤報為真實災害而重複出動。至於防火避難設施自行檢查採每月頻率，是因為常閉式防火門遭雜物阻擋、通道堆置物品這類缺失變化極快，半年一查已無法反映實況；檢查結果遇有缺失應報告管理權人立即改善，責任歸屬明確。\n易混淆對照：消防防護計畫屬防火管理體系，消防安全設備檢修申報屬《消防法》第 9 條體系，兩者的頻率（每月、每半年 對 每年、每半年）分屬不同制度，答題前務必先辨識題幹法源。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-fire-law-023","依消防法施行細則之規定，防火管理人應為管理或監督層次人員，並經中央消防機關認可之訓練機構或直轄市、縣（市）消防機關講習訓練合格領有證書始得充任。其講習訓練時數，初訓不得少於 X 小時；複訓不得少於 Y 小時，X、Y 分別為多少？",23,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-fire-law-025","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，室外儲槽場所係指在建築物外地面上設置容量超過多少公升且不可移動之儲槽儲存六類物品之場所？",25,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-fire-law-022","下列場所，何者不屬於消防法施行細則所定一定規模以上供公眾使用建築物？",22,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-fire-law-026","公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法所稱高閃火點物品，指閃火點在攝氏 X 度以上之第 Y 類公共危險物品，X、Y 分別為多少？",26,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-fire-law-021","依消防法之規定，下列何者錯誤？",21,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-fire-law-027","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，製造、儲存或處理六類物品達管制量多少倍以上之場所，應由管理權人選任管理或監督層次以上之幹部為保安監督人，擬訂消防防災計畫，報請當地消防機關核定，並依該計畫執行六類物品保安監督相關業務？",27,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-024",114,"依避難器具支固器具及固定部之結構、強度計算及施工方法規定，有關斜降式救助袋之下部支撐裝置固定在降落面等器具之構造、強度及埋設到降落面之方法，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-024",113,"有關避難器具支固器具及固定部之結構、強度計算及施工方法之規定，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-024",112,"某一消防設備士受託辦理一家辦公大樓消防安全設備檢修，該大樓依規定設置之全部緩降機經消防設備士執行下降檢查，測量每具緩降機之下降距離及下降時間，經計算出之平均下降速度全部符合規定，其緩降機之下降距離及下降時間，下列敘述何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-024",111,"某室外儲槽場所儲槽儲存第四類公共危險物品，儲槽容量合計為 25 萬公秉，防液堤高度應在多少公尺以上？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-024",110,"依各類場所消防安全設備設置標準規定，有關連結送水管之送水設計壓力規定計算，下列敘述何者錯誤？",1785129970583]