[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-fire-law-008":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-消防法規概要-008","fire-107-1-fire-law-008",107,1,8,"依避難器具支固器具及固定部之結構、強度計算及施工方法之規定，以金屬膨脹錨定螺栓之施工方法（輕形混凝土或氣泡混凝土製造者除外），若使用金屬膨脹錨定螺栓之口徑為 M20，其埋入深度需為多少毫米？",{"A":16,"B":17,"C":18,"D":19},"40","50","60","80","D",null,[],false,"本題考點：避難器具支固器具固定部採金屬膨脹錨定螺栓施工時，螺栓口徑與最小埋入深度的對應數值，出自《避難器具支固器具及固定部之結構、強度計算及施工方法》之施工方法規定。\n【正解理由】依《避難器具支固器具及固定部之結構、強度計算及施工方法》關於金屬膨脹錨定螺栓施工方法之規定（輕型混凝土或氣泡混凝土製造者除外），螺栓埋入深度須隨口徑加大而遞增，法定對照為 M10 埋入 40 毫米、M12 埋入 50 毫米、M16 埋入 60 毫米、M20 埋入 80 毫米。題目給定口徑 M20，對應之最小埋入深度即 80 毫米，故選 D。\n【逐項排除】\n(A) 40 毫米對應之口徑為 M10，是級距中最小的一組，用於 M20 明顯不足以提供所需拉拔強度。\n(B) 50 毫米對應 M12，仍屬小口徑組別，與題目所給 M20 不符。\n(C) 60 毫米對應 M16，是最容易被誤選的一格，因其緊鄰 M20，但法定數值在 M16 與 M20 之間是跳到 80 毫米而非連續遞增 20。\n(D) 80 毫米正是 M20 所定之埋入深度，與題意相符。\n【記憶點】十四、十二五、十六六、二十八——口徑與埋深成對背，M20 一口氣跳到 80。","金屬膨脹錨定螺栓（俗稱膨脹螺栓）的固定原理，是螺栓末端的擴張套管在鎖緊時向外撐開，藉由與混凝土孔壁之間的摩擦力與機械互鎖抵抗拉拔力。其可承受的拉拔強度大致與「埋入深度」及「混凝土抗壓強度」正相關，因此法規不是只管螺栓粗細，而是把口徑與埋入深度綁成一組最小值，避免出現「粗螺栓淺埋」這種看似牢固實則會整支拔出的組合。避難器具（緩降機、避難梯、救助袋等）在使用時要承受人員體重加上下降過程的動態衝擊，固定部一旦破壞就是致命事故，所以規定採取寧嚴勿寬的級距設計。\n條文特別排除「輕型混凝土或氣泡混凝土製造者」，理由在於這類材料孔隙率高、抗壓強度低，膨脹式錨栓撐開時容易造成孔壁壓潰而失去摩擦力，必須改採其他固定方式或另行強度計算，不能沿用本表數值。此一但書幾乎每次都會出現在題幹中，是判讀題意的關鍵字。\n數值可整理成對照表：M10／40 mm、M12／50 mm、M16／60 mm、M20／80 mm。記憶技巧是前三組大致「加 10 遞增」，最後一組直接跳到 80，命題者最愛在 M16 與 M20 之間設誘答。與本規定容易混淆的是「固定部強度計算」的另一組概念：支固器具本身的容許應力、固定部承受之設計荷重，以及使用螺栓數量與間距要求，這些屬於強度計算章節而非施工方法章節，考題會刻意混寫。相關考點還包括避難器具開口部大小、操作面積、下降空間與下降空地之淨空要求。※ 本規定屬中央主管機關頒定之技術規範，其分點編號與數值請以最新公布版本為準。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-fire-law-007","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，製造場所與收容人數在 300 人以上的三溫暖，安全距離需多少公尺以上？",7,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-fire-law-009","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，販賣場所內設六類物品調配室者，調配室出入口應設置多少小時以上防火時效之防火門？",9,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-fire-law-006","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，容器串接使用場所，係指使用液化石油氣作為燃氣來源，其串接使用量達多少公斤以上之場所？",6,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-fire-law-010","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，易燃液體，係指在一大氣壓時，閃火點在攝氏多少度以下之液體？",10,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-fire-law-005","依各類場所消防安全設備設置標準之規定，無線電通信輔助設備的無線電接頭之設置，下列何者錯誤？",5,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-fire-law-011","依建築技術規則建築設計施工編之規定，所謂的集合住宅，係指具有共同基地及共同空間或設備，並有幾個住宅單位以上之建築物？",11,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-008",114,"依消防安全設備設計監造測試及檢修作業辦法，消防設備人員對於所製作完成之檢修報告書，下列敘述何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-008",113,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，有關液化石油氣販賣場所經營者相關規範，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-008",112,"依消防設備師及消防設備士管理辦法之規定，下列敘述何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-008",111,"可燃性高壓氣體儲存場所防爆牆設置規定，下列何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-008",110,"依消防設備師及消防設備士管理辦法規定，消防設備師及消防設備士執行業務，應備業務登記簿，以書面簿冊形式或電子檔案方式，記載委託人姓名或名稱、住所、委託事項及辦理情形之詳細紀錄，並應妥善保存，以備各級消防機關之查核。上述業務登記簿保存年限至少幾年？",1785129970473]