[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-fire-law-006":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-消防法規概要-006","fire-107-1-fire-law-006",107,1,6,"依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，容器串接使用場所，係指使用液化石油氣作為燃氣來源，其串接使用量達多少公斤以上之場所？",{"A":16,"B":17,"C":18,"D":19},"40","80","128","1000","B",null,[],false,"本題考點：《公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法》對容器串接使用場所之定義門檻。\n【正解理由】依《公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法》第 4 條，容器串接使用場所係指以液化石油氣作為燃氣來源，其串接使用量達八十公斤以上之場所。此一門檻的意義在於：串接量達到該規模後，一旦洩漏所形成的可燃氣體雲量已足以造成重大氣爆，因此須納入容器放置位置、通風、與火源距離及安全管理之規範，故選 B。\n【逐項排除】\n(A) 四十公斤低於條文所定門檻，屬一般小型商家或住宅常見的使用量級，尚未達到本辦法對容器串接使用場所的管制起點。\n(B) 八十公斤正是條文明定之串接使用量門檻，達此量即構成容器串接使用場所並適用相關安全管理規定，為正解。\n(C) 一百二十八公斤並非本辦法所定的定義門檻，該類數字多出現於其他管制量或容器規格換算，套用於此即記錯。\n(D) 一千公斤數值過高，屬大量儲存或分裝場等級的概念，若以此為門檻將使絕大多數串接使用場所脫離管制，與立法目的不符。\n【記憶點】液化石油氣串接使用量八十公斤以上，就是容器串接使用場所。","液化石油氣以桶裝容器供氣時，餐飲業、小吃店、工廠常把多支容器以集合管串接，以維持穩定的氣化量。串接的容器愈多，同一地點的可燃氣體潛在總量愈大，洩漏時形成的爆炸性混合氣範圍也愈廣。法規因此不管制單支容器，而是以「串接使用量」作為門檻，達八十公斤以上即列為容器串接使用場所，納入管理。\n\n構成容器串接使用場所後，隨之而來的義務包括：容器不得設於地下室或通風不良處所、應與火源保持規定距離、容器放置場所之通風與遮陽要求、設置氣體漏氣警報設備或緊急遮斷裝置的規定，以及管理權人應遵行的安全管理事項。這些規定共同構成「早期偵知、限制洩漏量、隔離火源」的三層防護。\n\n易混淆概念對照：本辦法同時規範公共危險物品（第一類至第六類）與可燃性高壓氣體兩大體系。前者以「管制量」倍數決定是否為製造、儲存或處理場所並適用不同構造與安全距離；後者則以容器串接使用量、儲存量等重量門檻劃線。考生應把「管制量倍數」與「公斤門檻」分開記憶，避免互相污染。\n\n延伸考法包括：液化石油氣分裝場、儲存場所之設置規定、容器定期檢驗與認可制度、以及《消防法》對液化石油氣零售業者備置安全檢查資料並保存二年之申報義務，兩部法規常在同一題組交錯出現。液化石油氣的物性也支撐了這套管制邏輯：其蒸氣比重大於空氣，洩漏後會沿地面流動並積聚於低窪處與地下空間，不像天然氣會上升逸散，因此容器不得置於地下室、氣體漏氣警報設備的探測部須設於接近地面的位置。把物性、設置限制與定義門檻串成一條因果鏈記憶，遠比死背八十公斤這個數字牢固。※ 條號請以現行法規為準。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-fire-law-005","依各類場所消防安全設備設置標準之規定，無線電通信輔助設備的無線電接頭之設置，下列何者錯誤？",5,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-fire-law-007","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，製造場所與收容人數在 300 人以上的三溫暖，安全距離需多少公尺以上？",7,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-fire-law-004","依消防法施行細則之規定，液化石油氣零售業者應備置相關資料，並定期向轄區消防機關申報，指於每年 a 月及 b 月向轄區消防機關各申報一次，相關資料，零售業者應保存以備查核。a、b 各為何值？",4,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-fire-law-008","依避難器具支固器具及固定部之結構、強度計算及施工方法之規定，以金屬膨脹錨定螺栓之施工方法（輕形混凝土或氣泡混凝土製造者除外），若使用金屬膨脹錨定螺栓之口徑為 M20，其埋入深度需為多少毫米？",8,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-fire-law-003","依各類場所消防安全設備檢修及申報作業基準之規定，化學泡沫滅火器應每幾年實施一次性能檢查？",3,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-fire-law-009","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，販賣場所內設六類物品調配室者，調配室出入口應設置多少小時以上防火時效之防火門？",9,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-006",114,"依消防設備人員法規定，消防設備人員執行業務方式，下列敘述何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-006",113,"依各類場所消防安全設備設置標準規定，平時有特定或不特定人員使用之中央管理室、防災中心等類似處所，不得設置下列那一種滅火設備？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-006",112,"依消防法及消防法施行細則之規定，下列那一個建築物或場所，遇有增建、改建、修建、室內裝修施工時，應另定施工中消防防護計畫，以監督施工單位用火、用電情形？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-006",111,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，六類公共危險物品之儲存及處理，應遵守之規定，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-006",110,"消防設備師及消防設備士，自取得證書日起應定期接受講習訓練，下列敘述何者正確？",1785129970459]