[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-alarm-evacuation-018":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-警報與避難系統消防安全設備概要-018","fire-107-1-alarm-evacuation-018",107,1,18,"依各類場所消防安全設備設置標準規定，每一火警分區，依規定設置火警發信機，其標示燈應平時保持明亮，其透明罩為圓弧形，裝置後突出牆面，標示燈與裝置面應成幾度角？",{"A":16,"B":17,"C":18,"D":19},"五度角","十度角","十五度角","二十度角","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》關於火警發信機標示燈之設置角度規定。\n【正解理由】依《各類場所消防安全設備設置標準》關於火警發信機標示燈之規定，設有火警發信機之處所，其標示燈應平時保持明亮，標示燈與裝置面成十五度角，並在十公尺距離內須無遮視物且明顯易見；角度與距離是同一句話裡的一組要件，題目問的角度即十五度角，故選 C。\n【逐項排除】\n(A) 五度角過小，透明罩幾乎貼平牆面，沿牆走近的人在斜向視角下不易看見標示燈，非條文所定角度。\n(B) 十度角同樣小於條文所定值，僅是介於五度與十五度之間的干擾項，法規並無此數值。\n(C) 十五度角為條文明定之角度，配合圓弧形透明罩突出牆面，可使左右斜向接近者在十公尺距離內都能辨識，為正確答案。\n(D) 二十度角逾越條文所定值，角度過大會使正面接近者的可視亮度下降，法規亦無此規定。\n【記憶點】火警發信機標示燈「十五度角、十公尺內看得到」，角度與距離兩個數值要一起背。","為什麼要「與裝置面成十五度角」：火警發信機多設於走廊牆面，正對面看得見不代表沿牆走來的人看得見。透明罩做成圓弧形並突出牆面、燈面與裝置面（即牆面）夾十五度角，可讓左右斜向接近者在十公尺距離內都看到亮點；角度負責可視範圍，距離負責可視性的檢核基準，兩個數值是一組。標示燈須平時保持明亮，用意是在火災發生前就讓人記住發信機位置，濃煙或停電時才不必臨時尋找。\n同組設備的規定：依《各類場所消防安全設備設置標準》第 129 條，每一火警分區應設火警發信機，其按鈕按下時能即刻發出火警音響、按鈕前有防止隨意撥弄之保護板、附設緊急電話插座、裝置於屋外者具防水性能；二樓層共用一火警分區者，火警發信機應分別設置，但樓梯或管道間之火警分區得免設。發信機、標示燈與火警警鈴三者是手動報警的同一組設備，考題常合併出。\n數值對照：第 131 條規定火警警鈴在電壓到達規定電壓之百分之八十時能即刻發出音響、在規定電壓下離開火警警鈴一百公分處所測得之音壓在九十分貝以上、電鈴絕緣電阻以直流二百五十伏特額定之絕緣電阻計測定在二十ＭΩ以上，且警鈴音響應有別於建築物其他音響，除報警外不得兼作他用；依本章第三節設有緊急廣播設備時，得免設火警警鈴。\n相關考點連結：本考點常與第 112 條火警分區劃定併考——每一火警分區不得超過一樓層且樓地板面積在六百平方公尺以下、每一分區任一邊長在五十公尺以下（裝設光電式分離型探測器時邊長得在一百公尺以下）、由主要出入口或直通樓梯出入口能直接觀察該樓層任一角落時六百平方公尺得增為一千平方公尺。分區怎麼劃、每一分區要配置幾處發信機與標示燈，是同一組題目的兩面：分區數決定設備數量，標示燈的角度與可視距離則決定該設備在現場「找不找得到」，前者是量、後者是質。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-alarm-evacuation-017","供緩降機或救助袋使用之支固器具及供懸吊型梯、滑杆或避難繩索使用之固定架，若使用螺栓固定時，下列何者錯誤？",17,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-alarm-evacuation-019","在設置避難器具時，皆必須考慮其開口部保有必要開口面積、無操作障礙之面積、下降空間及下降空地等因素，試問於設置避難器具為緩降機時，下列敘述何者錯誤？",19,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-alarm-evacuation-016","避難器具之設置數量與場所之收容人數有很大的關係，依各類場所消防安全設備設置標準規定，有關醫療機構（醫院、診所）候診室之收容人數之計算，應以各候診室之樓地板面積和除多少平方公尺所得之數，做為候診室之收容人數？",16,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-alarm-evacuation-020","依各類場所消防安全設備設置標準規定，瓦斯漏氣警報裝置之檢知器所能檢知瓦斯漏氣之區域內，該檢知器動作時，該區域內之檢知區域警報裝置能發出警報音響，其音壓在距 1 公尺處應有多少分貝以上？",20,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-alarm-evacuation-015","有關緊急供電系統之電源，下列何者錯誤？",15,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-alarm-evacuation-021","依各類場所消防安全設備設置標準規定，緊急照明設備除內置蓄電池外，應連接緊急電源，其蓄電池容量應能使其持續動作 a 分鐘以上。但採蓄電池設備與緊急發電機併設方式時，其容量應能使其持續動作分別為 b 分鐘及 c 分鐘以上，請問下列何者正確？",21,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-018",113,"探測器容易因設置環境影響其探測能力，因此需考慮設置處所環境，根據各類場所消防安全設備設置標準之要求，補償式局限型二種探測器不適合安裝在下列場所？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-018",112,"消防安全設備及必要檢修項目檢修基準的緊急照明設備於性能檢查時，判定方法下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-018",111,"局限型偵煙探測器光電式的偵測原理若設計為散亂光式，其對火場中何種信號較不敏感？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-alarm-evacuation-018",110,"下列避難器具架設完成後，進行綜合檢查時，何者應判定不合格？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-alarm-evacuation-018",109,"依住宅用火災警報器認可基準之規定，住宅用火災警報器以警報音發出火災警報，於無響室中距離警報器中心前方 1 公尺處，音壓應有多少分貝以上？",1785129965146]