[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-106-1-water-chemical-029":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-水與化學系統消防安全設備概要-029","fire-106-1-water-chemical-029",106,1,29,"10 型乾粉滅火器乾粉充填量約為多少公斤重？",{"A":16,"B":17,"C":18,"D":19},"2.5","3.5","6.5","10 1\u002F2","B",null,[],false,"本題考點：滅火器「型號數字」與乾粉藥劑充填量之對應關係。\n【正解理由】依滅火器認可基準所建立的型別命名慣例，乾粉滅火器以型號標示規格，10 型手提式乾粉滅火器之藥劑充填量約為 3.5 公斤重，這也是市面最普遍、能力單位常見標示為 A-3、B-10、C 之機型，故選 B。型號數字對應的是滅火器整體規格級別，不是藥劑公斤數，這正是本題設計的辨識點。\n【逐項排除】\n(A) 2.5 公斤重為更小型手提式機型之充填量，常見於車用或小空間配置，型號級別低於 10 型。\n(B) 正確。10 型乾粉滅火器充填量約 3.5 公斤重，是建築物室內常見的標準配置機型。\n(C) 6.5 公斤重屬更大型手提式機型之充填量，型號級別高於 10 型，兩者外觀與瓶身高度差異明顯。\n(D) 「10 1\u002F2」既非重量單位亦非既有型別標示，把型號數字 10 直接當成公斤數再加附註，屬混淆用的干擾選項。\n【記憶點】型號不是公斤數：10 型乾粉滅火器裝的是約 3.5 公斤重藥劑。","滅火器的規格標示有兩套系統，考生常混為一談。第一套是「型別」，例如 10 型、20 型，屬於產品規格級別的傳統稱呼，與充填量並非等值關係；第二套是「滅火效能值（能力單位）」，以 A、B、C 分類標示，例如 A-3、B-10、C，代表對普通火災、油類火災與電氣火災的適用性與滅火能力。手提式乾粉滅火器最常見的 10 型，其充填量約 3.5 公斤重，滅火效能值常見為 A-3、B-10、C，這也是為什麼許多人誤以為「10 型」的 10 是來自 B-10 的能力值——兩者數字巧合，成因不同。\n乾粉藥劑本身也需分辨。第一種乾粉為碳酸氫鈉（小蘇打），適用 B、C 類火災，粉末呈白色；第二種為碳酸氫鉀，滅火效能較第一種佳；第三種為磷酸二氫銨，即俗稱的 ABC 乾粉，能在 A 類火災表面形成熔融被覆層，適用範圍最廣，粉末常呈淡紫或淡黃色；第四種為碳酸氫鉀與尿素之反應物。台灣建築物內配置者以第三種為大宗。\n配置面的規則也常一起考：滅火器應設於明顯易取之處，設有固定放置架，其上端與樓地板面之高度在一定範圍內，且各層任一點至滅火器之步行距離有上限，並依場所用途與樓地板面積計算所需滅火效能值。滅火器的檢查週期、壓力指示錶指針落在綠色區間代表正常、以及乾粉有無結塊等，也屬同一題族。\n記憶策略：把「型別＝瓶身大小、能力值＝滅得掉多少火」兩件事分開背，遇到型號與公斤數對應的題目就不會被數字巧合帶著走。\n命題角度上，這種題不考推理，考的是有沒有實際看過、拿過滅火器：3.5 公斤重的 10 型瓶身高度約 50 公分上下，單手可提；6.5 公斤重者明顯粗重，多見於工廠與停車空間；2.5 公斤重者體積小，常固定於車輛或機房。把重量、瓶身尺寸與常見設置場所三者串成一組畫面記憶，比背數字牢靠得多。另可留意乾粉為加壓式或蓄壓式的差別：蓄壓式瓶身附壓力指示錶，藥劑與推進氣體共存於同一容器；加壓式另設加壓氣體小鋼瓶，操作時擊發後才增壓，兩者的檢查重點與常見劣化型態並不相同。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-water-chemical-028","末端查驗管量測到的壓力為何？",28,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-water-chemical-030","第一種感度之撒水頭其反應時間指數（RTI）應小於多少 (ms) ？",30,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-water-chemical-027","依各類場所消防安全設備設置標準，連結送水管之出水口設置，下列敘述何者錯誤？",27,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-water-chemical-031","B-30 乾粉滅火器可以滅火之油盤面積為多少平方公尺？",31,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-water-chemical-026","消防專用蓄水池至建築物各部分之水平距離，應在多少公尺以下？",26,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-106-1-water-chemical-032","二氧化碳全區放射方式之安全裝置，啟動裝置開關或拉桿開始動作至儲存容器之容器閥開啟，設有多少秒以上之遲延裝置？",32,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-029",113,"有關流水檢知裝置之構造，依據流水檢知裝置認可基準規定，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-water-chemical-029",112,"有關泡沫滅火設備，依各類場所消防安全設備設置標準規定，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-water-chemical-029",111,"變電站場所設置水霧滅火設備，放射區域 6 個分區，其消防幫浦出水量需達每分鐘 X 公升以上；且每顆水霧噴頭放水壓力均能達每平方公分 Y 公斤以上，請問前述 X、Y 為何？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-water-chemical-029",110,"公共危險物品等場所消防設計及消防安全設備，設置第五種滅火設備者，公共危險物品每達管制量之幾倍（含未滿）應有一滅火效能值？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-water-chemical-029",109,"泡沫原液與水混合使用之濃度，下列何種原液之濃度為 1%？",1785129973553]