[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-106-1-water-chemical-008":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-水與化學系統消防安全設備概要-008","fire-106-1-water-chemical-008",106,1,8,"乾粉滅火設備進行性能檢查時，滅火藥劑檢查注意事項中，溫度超過Ｘ℃以上，濕度超過Ｙ%以上時，應暫停檢查，Ｘ及Ｙ分別為：",{"A":16,"B":17,"C":18,"D":19},"Ｘ＝40，Ｙ＝60","Ｘ＝60，Ｙ＝40","Ｘ＝30，Ｙ＝40","Ｘ＝30，Ｙ＝60","A",null,[],false,"本題考點：《消防安全設備檢修及申報作業基準》中乾粉滅火設備性能檢查時，滅火藥劑檢查的環境溫濕度限制。\n【正解理由】依《消防安全設備檢修及申報作業基準》有關乾粉滅火設備性能檢查之滅火藥劑檢查注意事項，因乾粉藥劑極易吸收水分而結塊、固化，一旦受潮即喪失流動性與噴射性能，故明定實施檢查時如溫度超過 40℃以上、濕度超過 60%以上，應暫停檢查，待環境條件回復後再行實施。這道門檻是為了避免開蓋秤重或取樣時，高溫高濕的空氣接觸藥劑而使其吸濕結塊，屬於保護受檢藥劑本身的規定。是以 Ｘ 為 40、Ｙ 為 60，故選 A。\n【逐項排除】\n(A) 正確：溫度 40℃ 以上、濕度 60% 以上即為基準所定之暫停檢查門檻，兩者只要其一超過即應暫停。\n(B) Ｘ＝60、Ｙ＝40 是把溫度與濕度兩個數值對調，40 與 60 位置顛倒，屬最常見的誤記型態。\n(C) Ｘ＝30、Ｙ＝40 兩個數值皆低於規定門檻，溫度與濕度都取錯，等於把限制訂得比法定更嚴而無依據。\n(D) Ｘ＝30、Ｙ＝60 濕度數值雖與規定相符，但溫度誤植為 30℃，與基準所定的 40℃ 不符，是最容易誤選的干擾項。\n【記憶點】乾粉怕潮，四十度、六十濕就先收工。","乾粉滅火藥劑的滅火機制以負觸媒（化學抑制）為主，靠細微粉粒在火焰中捕捉自由基來中斷連鎖反應，因此粒徑分布與流動性是性能命脈。藥劑主成分多為碳酸氫鈉、碳酸氫鉀或磷酸二氫銨等鹽類，這些鹽類具吸濕性，一旦吸附水分便會在粒子表面形成液橋並逐漸結塊，輕則放射時粉體不易流化、噴射不均，重則在配管或噴頭處堆積阻塞，導致系統形同虛設。也因此製造時會添加防濕撥水處理，而檢修時更要求避開高溫高濕環境開蓋檢查，這就是 40℃、60% 這組門檻的由來，屬於「保護受檢設備本身」的規定，而非人員作業限制。\n\n乾粉藥劑常見分類可整理為：第一種以碳酸氫鈉為主，適用 B、C 類火災；第二種以碳酸氫鉀為主，滅火效能高於第一種；第三種為磷酸二氫銨，可涵蓋 A、B、C 類火災，因此又稱多效乾粉；第四種為碳酸氫鉀與尿素之反應物。不同種類的單位體積藥劑量、噴射量規定不同，是設置標準的另一組高頻考點。\n\n性能檢查的其他要項也常一併命題：滅火藥劑應確認有無變色、結塊與異物，並確認量是否在規定範圍；蓄壓式者應查壓力指示值是否落在綠色範圍；加壓用氣體容器應確認容器閥開放裝置動作正常；定壓動作裝置應在容器內壓達規定值時才使放出閥開啟，避免粉體未充分流化即放射；清洗裝置則用於放射後排除殘留粉體，防止結塊堵管。\n\n把數值整理成對照更好記：暫停檢查條件為溫度 40℃ 以上或濕度 60% 以上，兩者只要其一超過即應暫停；而簡易自動滅火設備蓄壓式藥劑量允許差異為 3% 以內，兩組數字常被交錯設計成干擾選項，宜分開建立記憶錨點。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-water-chemical-007","依各類場所消防安全設備設置標準，二氧化碳滅火設備之藥劑放射時間，下列何者正確？",7,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-water-chemical-009","如無額外防止乾粉與加壓氣體分離之措施，乾粉滅火設備之配管任一部分與彎曲部分之距離，至少應為其管徑的多少倍？",9,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-water-chemical-006","全區放射二氧化碳滅火設備進行綜合檢查時，如為低壓式儲存系統，在放射試驗時需放射多少藥劑量？",6,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-water-chemical-010","一汽車修理廠欲採用移動式乾粉滅火設備，則其外牆開口面積（常時開放部分）須符合下列那一規定？",10,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-water-chemical-005","某一鍋爐房之長寬高分別為 8 m、5 m 及 4 m，若設置全區放射 CO2 滅火設備，其所有開口皆可在放射前自動關閉，試問所需 CO2 藥劑量至少應為多少公斤？",5,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-106-1-water-chemical-011","鹵化烴滅火設備進行性能檢查時，控制裝置之遲延裝置檢查項目，於操作啟動按鈕後至容器閥開放裝置動作，其所需時間應為：",11,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-008",113,"有關幫浦之形狀、構造部分，依據消防幫浦認可基準規定，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-water-chemical-008",112,"某引擎試驗室設置有泡沫滅火設備，採高發泡放出口局部放射方式，依規定高發泡放出口之泡沫水溶液放射量，防護面積每 1 平方公尺應在每分鐘 X 公升以上。又防護面積係指防護對象外周線以高出防護對象物高度 Y 倍數值（該數值小於 1 公尺時，以 1 公尺計）所包圍之面積。其中 X+Y=？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-water-chemical-008",111,"固定式泡沫滅火設備（低發泡）進行綜合檢查作業時，發泡倍率應在幾倍以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-water-chemical-008",110,"消防搶救上之必要設備中，連結送水管之送水口設置，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-water-chemical-008",109,"預動式自動撒水設備竣工測試進行放水試驗時，開放末端查驗閥後，應在多久時間內正常放水？",1785129973420]